Laserfiche WebLink
1/8/2020 Page 1 <br /> City of Everett <br /> 2:19:09PM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. M1905-047 Site Address 3915 COLBY AVE <br /> Applied 5/15/2019 Applicant Lot <br /> Approved 5/15/2019 Owner HARVEST CASCADIAN RTRMNT RES LLC Block <br /> Issued 5/15/2019 Contractor POLAR BEAR MECHANICAL INC Tract <br /> Parent Permit No. Description REPLACE EXTG WALK-IN COOLER/FREEZER,USING EXTG <br /> Notes <br /> Scheduled Completed Type Inspector Result Remarks Inspector's Comments <br /> 6/4/2019 6/4/2019 MECH 04-ROUGH RRS CORRECTION AM Inspection requested <br /> IN 425-967-5827 <br /> (2)condensate lines not piped to approved <br /> location-insulate copper lines of front <br /> cooler/freezer. <br /> 6/6/2019 6/6/2019 MECH 04-ROUGH SDP APPROVAL see notes AM Inspection requested <br /> IN 425-967-5827 <br /> (6/6/2019 1:00 PM SDP) <br /> Rough in:refer pressure test is ok <br /> For Final approval: <br /> 1)Insulate the complete condensate piping <br /> inside the cooler <br /> 2)Seal all penetrations made in the <br /> cooler/freezer <br /> 3)Correct the grade of the condensate line <br /> outside the cooler,it must grade downward <br /> a 1/4"per foot. <br /> 6/13/2019 6/13/2019 MECH 06-FINAL RRS CORRECTION (6/13/2019 2:10 PM RRS) <br /> horizontal condensate line in cooler still not <br /> insulated.line under the pan only. <br /> INSP12CM- <br /> ..)YSTEtviS <br />