My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Drew Martin <br /> Plan Check Number: B1901-029, First Building Review Letter Response <br /> April 30, 2019 <br /> a. The wall design does not appear to be complete. Missing information includes but is not <br /> limited to;material requirements for the CMU blocks, grout, and reinforcement;rebar <br /> vertical and horizontal spacing;and foundations. See IBC Sections 1072.1 and 1603.1. <br /> Response: <br /> The wall design is no longer applicable. The proposed stairs to the entry door has been <br /> eliminated from this project, no new site work is proposed. <br /> b. Structural calculations for the design of the wall shall be submitted for review. The wall <br /> is located adjacent to parking spaces and must support vehicle surcharge loads in <br /> addition to active and seismic surcharge pressures See IBC Sections 1604.1, 1605.1.1, <br /> 1605.2, 1610.1, and 18072. <br /> Response: <br /> Structural calculations for the design of the wall are no longer applicable. The proposed stairs to <br /> the entry door has been eliminated from this project, no new site work is proposed. <br /> 5. The handrail in Section A A/A-3.0, including the base connections, shall be design for the <br /> loads per IBC Section 1607.8. Calculations substantiating the design shall be submitted for <br /> review. Additional detailing for the handrails, including but not limited to the post base <br /> plates and welding, and post maximum spacing, shall be specified in the drawings. Note <br /> that Section A-A appears to only require connections at the top and bottom post; the <br /> intended construction shall be reviewed and revised as needed. See IBC Sections 1072.1, <br /> 1603.1, and 1604.1. <br /> Response: <br /> Section A-A/A-3.0 has been removed from sheet A-3.0. The proposed stairs to the entry door <br /> has been eliminated from this project. <br /> 6. Plans Basement plans on Sheets A-1.0 and A-1.2 appear to indicate that a new guardrail <br /> shall be provided along the existing wall. At a minimum, an existing guardrail must extend <br /> along the new section of retaining wall adjacent to the new stairs at the southwest building <br /> corner. The following comments shall be addressed: <br /> Response: <br /> The existing guardrail along the existing wall to remain, drawings have been revised and <br /> dimensions added, See sheets A-0.3, A-2.2 <br /> O523 61sT ST SE 0 425.879.3437 O brianbodge@msn.com <br /> Everett, WA 98203 <br /> C9710 <br />
The URL can be used to link to this page
Your browser does not support the video tag.