Mr. Drew Martin <br /> Plan Check Number: B1901-029, Second Building Review Letter Response <br /> July 30, 2019 <br /> Geotechnical <br /> 1. No additional comment. <br /> Architectural <br /> General: <br /> 1, No additional comment, <br /> 2. No additional comment, <br /> Fire Protection; <br /> 3. This comment has not been completely addressed. The original comment addressed the fire <br /> separate distance to the adjacent building on the north side, and the required construction of the <br /> north wall for fire protection, The following comment shall be address: <br /> a. The Site Plan on Sheet C-1,0 indicates a 9'-7"separation. However, the lot line dimensions of 4/- <br /> 9"equate <br /> -9"equate to a 9'-6"separation. The dimensions should be consistent. <br /> Response: <br /> Dimensions on Sheet C-1.0 have been revised to be consistent. <br /> b. Due to the unknown conditions of the exterior wall construction for the adjacent building, the <br /> adjacent building shall be provided with a 5-foot fire separation distance to the lot line. <br /> Response: <br /> Dimensions on Sheet C-1.0 have been revised to provide the adjacent building with a 5-foot <br /> fire-separation distance to the lot line. <br /> c. An elevation should be provided for the north wall to specify the proposed construction stated in <br /> the response, <br /> Response: <br /> Elevation on the north wall not required to show/find compliance. <br /> d. Section 1/A-3.0 specifies a 20 MIL coating of intumescent paint, The submitted documentation <br /> does not dearly indicate the specified coating provides 2-hour protection for the existing <br /> construction. Additional documentation substantiating the proposed system shall be submitted <br /> for review. <br /> Response: <br /> Intumescent paint will not be required. The lower portion of the north wall will be modified <br /> to the specifications per IBC Table 721.1(2), 15. Exterior or interior walls, item 15-1.16 and <br /> per American Wood Council WS6-2.1 Two-Hour Fire-Resistive.Wood Wall Assembly detail <br /> with 2x6 wall framing clad symmetrically on both sides with two layers of 5/8"Type X GWB. <br /> See detail of proposed modification on sheet A-3.0. <br /> O523 61sT ST SE © 425.879.3437 brianbodge@msn.com <br /> Everett,WA 98203 i lel <br />