Laserfiche WebLink
if Npull > P, = "Stud dimension is ok" <br /> "Stud dimension is ok" <br /> else <br /> "change stud dimension" <br /> Results: <br /> 1 nelson stud <br /> Vertical spacing= 1ft <br /> Horizontal spacing = 8ft <br /> 1/2" dia <br /> embedment depth= 6inch. <br /> Headed Stud Size: <br /> 1/2"X 6 1/8" <br />