Laserfiche WebLink
Geotechnical Engineering Report <br /> Staples Rockery Failure Everett,Washington lierracon <br /> March 8, 2019 Terracon Project No. 81175122 <br /> retain the unsupported soil. Furthermore, removal of the rockery in short sections, or slots, <br /> will help mitigate the potential for sloughing after the rockery is deconstructed and before <br /> lagging is placed. <br /> Backfilling. For temporary excavations, trenches,voids behind the retaining wall, and the <br /> headscarp of the failed section, backfilling should occur after temporary wood lagging has <br /> been placed for the full height of the retaining wall. This will help reduce the further loading <br /> on the building wall within the existing failed section. <br /> As of the publishing of this report, overhead utilities exist adjacent to the rockery and will be an <br /> obstruction during retaining wall construction. The contractor will need to work with the City and <br /> other public utilities to relocate the overhead utilities. <br /> Surface water should not be allowed to pond on the site and soak into the soil during or after <br /> construction. Construction staging should provide drainage of surface water and precipitation <br /> away from the retaining wall.Any water that collects over or adjacent to construction areas should <br /> be promptly removed. Surface water control in the form of sloping surfaces, drainage ditches and <br /> trenches, and sump pits and pumps will be important to avoid ponding and associated delays due <br /> to precipitation and seepage. <br /> 4.3 Seismic Considerations <br /> Code Used Site Classification <br /> International Building Code (IBC) and 2010 ASCE 71 D2 <br /> S5—Short Period Spectral Acceleration for Site Class B 1.378 g <br /> Si — 1-Second Period Spectral Acceleration for Site Class B 0.523 g <br /> Fa—Short Period Site Coefficient for Site Class D 1.0 <br /> Fv— 1-Second Period Site Coefficient for Site Class D 1.5 <br /> PGA-ASCE 7-10, Peak Ground Acceleration 0.570 <br /> FPGA-Peak Ground Acceleration Site Coefficient 1.0 <br /> 1. The 2010 ASCE 7 document indicates that the seismic site classification is based on the average <br /> soil and bedrock properties in the top 100 feet. The current scope does not include a 100-foot soil <br /> profile determination. This seismic site class definition considers that soil encountered at depth in <br /> our explorations continue below the termination depths. Additional exploration to deeper depths <br /> would be required to confirm the conditions below the current depth of exploration. <br /> 2. Site Class D applies to an average soil profile within the top 100 feet consisting predominantly of <br /> stiff and dense to very dense soils. This soil is characterized by Standard Penetration Test blow <br /> counts between 15 to 50, a shear wave velocity of between 600 and 1,200 feet per second, and an <br /> undrained shear strength between 1,000 and 2,000 pounds per square foot. <br /> Responsive • Resourceful ■ Reliable 9 <br />