My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9930 EVERGREEN WAY TWO MEN AND A TRUCK 2020-02-07
>
Address Records
>
EVERGREEN WAY
>
9930
>
TWO MEN AND A TRUCK
>
9930 EVERGREEN WAY TWO MEN AND A TRUCK 2020-02-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2020 11:01:35 AM
Creation date
2/7/2020 11:00:51 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9930
Tenant Name
TWO MEN AND A TRUCK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Lactrical Permit Checklist, F, 4 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: A19-241 TWO MEN&A TRUCK TENANT IMPROVEMENT Date 4/15/2019 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> MOTORS&TRANSFORMERS <br /> No C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; <br /> indicate transformer size,efficiency,or exception taken <br /> Dwelling unit Indicate on electrical plans that each dwelling unit in Group R-2 <br /> No C405.7 electrical energy has a separate electrical energy meter <br /> consumption <br /> Electric motor Include all motors,including fractional hp motors,in electric <br /> No C405.8 motor schedule on electrical plans;indicate hp,rpm,rated <br /> efficiency <br /> efficiency,or exception applied <br /> For luminaires in each elevator cab,provide calculated average <br /> efficacy of combined fixtures that indicates efficacy is not less <br /> than 35 lumens per watt; <br /> No C405.9.1 Elevator cabs Indicate rated watts per cfm for elevator cab ventilation fans do <br /> not exceed 0.33 watts per cfm; <br /> Indicate automatic controls that de-energize lighting and <br /> ventilation fans when elevator is stopped and unoocupied for a <br /> period of 15 minutes or more <br /> Escalators and Indicate escalators comply with ASME A17.1/CSA B44; <br /> No C405.9.2 moving walks automatic controls are configured to reduce operational speed <br /> to the minimum permitted when not in use <br /> No C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided <br /> with a variable frequency regenerative drive <br /> Identify all controlled and uncontrolled receptables on electrical <br /> plans in each space in which they are required;include <br /> Controlled receptacle configuration such as spacing between controlled <br /> No C405.10 and uncontrolled,duplex devices,etc; <br /> receptacles — <br /> Indicate on plans whether the method of automatic control for <br /> each controlled receptable zone is by occupant sensor or <br /> programmable time-of-day control <br /> If"no"is selected for any question, provide explanation: <br /> I i <br /> I'I II <br /> End of Lighting,Motor&Transformer Permit Documents Checklist <br />
The URL can be used to link to this page
Your browser does not support the video tag.