Laserfiche WebLink
• <br /> Client: BECU-EVERETT WA P2 Job# CS18-181 (ATM ID#: n/a <br /> Address: EVERETT,WA 98204 Date: 9/2018 2 <br /> STRUCTURAL DESIGN CRITERIA 2015 International Building Code/ASCE 7-10 <br /> 1 Physical Dimensions for 5501 Kiosk <br /> Overall Height 120 in Canopy Height 6 in. <br /> Width 64.5 in Canopy Depth 112 in. <br /> Depth 60 in Overhang 48 in. <br /> Canopy Width 72.5 in. <br /> 2 Vertical Loads <br /> a.Dead Loads <br /> Dead Loading Total <br /> 1. Frame 1500.0 <br /> 2. Canopy 500.0 8.9 psf <br /> 3. Misc 400 <br /> 4. ATM 3000 <br /> Total 2400 LBS,frame analysis <br /> (less ATM weight) <br /> Total 5400 LBS,foundation overturn <br /> (including ATM weight) <br /> b. Live Loads <br /> Design Live Load= 20.0 psf <br /> c. Snow Loads Pf=0.7(Ce)(Ct)is(Pg) ASCE 7-10 Eqn.7.3-1 <br /> Ce= 1.0 Table 7-2 <br /> Pf= 20.02 psf Ct= 1.1 Table 7-3 <br /> is 1 Table 1.5-2 <br /> Design Roof Snow Load: 20.0 psf Pg= 26.0 psf <br />