My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5010 VIEW DR 2018 Plans 2022-11-23
>
Address Records
>
VIEW DR
>
5010
>
Plans
>
5010 VIEW DR 2018 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:00:43 PM
Creation date
2/12/2020 1:23:19 PM
Metadata
Fields
Template:
Address Document
Street Name
VIEW DR
Street Number
5010
Permit
B1803-061
Year
2018
Notes
INSTALL 1 PORTABLE WITH WELCOME RAMP AND LANDING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 . ' <br /> D <br /> GENERAL NOTES ABBREVIATIONS <br /> . � <br /> 1. PERFORM WORK IN ACCORDANCE WITH APPLICABLE 8P8C 8-POSITION, 8-CONDUCTOR ` � � � • , <br /> PNL PANEL <br /> NATIONAL AND STATE CODES AS AMENDED LOCALLY PP PATCH PANEL <br /> AND ENFORCED BY THE AHJ. ABV ABOVE <br /> AC AIR CONDITIONING; ALTERNATING CURRENT PVC POLYViNYL CHLORIDE . - - . - ' <br /> 2. OBTAIN AND PAY FOR PERMITS REQUIRED FOR <br /> AFF ABOVE FINISHED FLOOR � � � �� � �� � <br /> INSTALLATION OF WORK. ARRANGE AND SCHEDULE <br /> REQUIRED INSPECTIONS. AFG ABOVE FINISHED GRADE <br /> AWG AMERICAN WIRE GAUGE RCP REFLECTED CEILING PLAN • <br /> 3. DRAWINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE REC RECEPTACLE � � <br /> COMPONENTS AS REQUIRED FOR A COMPLETE BEP BUILDING ENTRANCE PROTECTION <br /> OPERATIONAL SYSTEM WHETHER OR NOT BLDG BUILDING REF REFER TO � <br /> SPECIFICA�LY SHOWN ON THE DRAWlNGS. REV REVISION H /� R G I S � � <br /> 4. DEVICE ROUGH-W LOCATIONS SHOWN ARE C CONDUIT RM ROOM . <br /> CAT CATEGORY melehcatric�a► 1201 third avenue,suite 600 <br /> APPROXIMATE. RMFC RACK MOUNT F(BER CABINET seattle,washington 98101 <br /> CATV COMMUNITY ANTENNA TELEVISION telecommunications <br /> security <br /> RU RACK UNIT ener t 206.44$.3376 w hatgis.biz <br /> 5. COMPLETION OF WORK SHALL BE EXECUTED IN CFCI CONTRACTOR-FURNISHED �' , � <br /> ACCORDANCE WITH THE PROJECT SCHEDULE. CONTRACTOR-INSTALLED <br /> SCHEDULE INSTALLATION WITH OTHER TRADES TO SHT SHEET <br /> ENSURE PROJECT MILESTONES ARE MET. <br /> (E) EXISTING SM SINGLEMODE � � � � . • <br /> EIA ELECTRONIC INDUSTRIES ASSOCIATION SMFC SURFACE MOUNTED FIBER CABINET <br /> NON-STRUCTURAL ELECTRICAL EMT ELECTRICAL METALLIC TUBING � � `�` � <br /> COMPONENT NOTES SMR SURFACE METAL RACEWAY <br /> EQUIP EQUIPMENT SPEC SPECIFICATIONS � <br /> C C <br /> 1. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM TBB TELECOMMUNICATIONS BONDING BACKBONE <br /> THE 2015 INTERNATIONAL BUILDING CODE AND FROM F FUSE; DEGREES FAHRENHEIT <br /> THE AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) FA FIRE ALARM TEL TELEPHONE <br /> STANDARD 7-05. THE CONTRACTOR SHALL REFER TO TELCO TELEPHONE COMPANY <br /> THE ABOVE FOR ADDITIONAL INFORMATION, <br /> FAAP FIRE ALARM ANNUNCIATOR PANEL TGB TELECOMMUNICATIONS GROUNDWG BUSBAR �?j°��� <br /> EXCEPTIONS, AND FURTHER DESCRIPTIONS. THE FACP FIRE ALARM CONTROL PANEL TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION <br /> CONTRACTOR SHALL ADHERE TO REQUIREMENTS AND FURNISHED BY OWNER INSTALLED BY . . � � � � <br /> AS SUCH, SHALL BE INCLUDED WITMIN BID. ALSO REFER FOIC CONTRACTOR TELECOMMUNICATIONS MAIN GROUNDING � � <br /> TO SPECIFICATIONS. TMGB gUSBAR <br /> FO10 FURNISHED BY OWNER INSTALLED BY OWNER TR TELECOMMUNICATIONS ROOM LOWeI I ES �O � V <br /> 2. 2015 IBC, 1613.1, SCOPE: ARCHITECTURAL, MECHANICAL, FSD FIRE SMOKE DAMPER TTB TELEPHONE TERMINAL BOARD _ <br /> ELECTRICAL, AND NON-STRUCTURAL COMPONENTS �/ TELEVISION POI IC�IJIeS � <br /> THAT ARE PERMANENTLY ATTACHED TO STRUCTURES <br /> AND THEIR SUPPORTS AND ATTACHMENTS SHALL BE G GROUND TYP TYPICAL FOR ' <br /> DESIGNED AND CONSTRUCTED TO RESIST THE <br /> EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE GFI GROUND FAULT INTERRUPTER <br /> WITH ASCE 7-10, EXCLUDING CHAPTER 14 AND GFCI GROUND FAULT CIRCUIT INTERRUPTER UG UNDERGROUND EVP re l l P U�I I C <br /> APPENDIX 11A. <br /> GND GROUND UL UNDERWRITERS LABORATORIES I <br /> 3. DIVISION 26, 27 & 28 RESPONSIBILITIES: UON UNLESS OTHERWISE NOTED SCI IOO S <br /> A. HANGERS AND SEISMIC BRACING FOR HC HORIZONTAL CROSS CONNECT UPS UNINTERRUPTIBLE POWER SUPPLY AT <br /> ELECTRICAL SYSTEMS SHALL BE DESIGNED AND UTP UNSHIELDED TWISTED PAIR . <br /> SPECIFIED BY DIVISION 26, 27 &28. DIVISION 26, IDF WTERMEDIATE DISTRIBUTION FRAME - <br /> 27 & 28 SHALL REFER TO THE ELECTRICAL cJO� O VIGW Dr . <br /> - DRAWINGS FOR LOCATIONS OF EQUIPMENT AND V VOLTS Everett WA 98203 � � - <br /> ELECTRICA� SYSTEMS. � JUNCTION VA VOLT AMPERES <br /> B, DIVISION 26, 27 & 28 SHALL COORDINATE THE <br /> SUPPORT SYSTEMS AND DESIGN LOADS FOR VP VIDEO PROJECTOR , <br /> HUNG RACEWAYS AND OTHER ELECTRICAL KCMIL THOUSAND CIRCULAR MILS VPP VOICE PATCH RANEL BUILDING PERMIT� � <br /> SYSTEMS (WCLUDING COMBWED MULTIPLE <br /> g RACEWAY RUNS) WITH THE PORTABLE 03/29/2018� g <br /> MANUFACTURER. LAN LOCAL AREA NETWORK W WATT; WIRE , <br /> This drawing is ' <br /> LEC LOCAL EXCHANGE CARRIER W/ WITH <br /> 1. Copyright 2018 Dykeman, Inc. <br /> LTG LIGHTING W/O WITHOUT 2. The Architect's Instrument of Professionai Service. . <br /> 3. For use on this project only. Obtain Architect's <br /> WA WORKSTATION AREA written permission for any other use or reproduction. . � <br /> MC MAIN CROSS CONNECT; METAL CLAD (CABLE) � <br /> WAN WIDE AREA NETWORK . . � . , <br /> MDF MAIN DISTRIBUTION FRAME WAP WIRELESS ACCESS POINT <br /> MH MANHOLE <br /> MIN MINIMUM WG WIRE GUARD ZO� H—003 � <br /> MM MULTIMODE WP WEATHERPROOF y <br /> MPOE MAIN POINT OF ENTRY <br /> MPOP MAIN POINT OF PRESENCE � <br /> XMFR TRANSFORMER . <br /> MTD MOUNTED " <br /> MARK DATE DESCRIPTION <br /> (N) NEW ` <br /> NEC NATIONAL ELECTRICAL CODE <br /> NEMA NATIONAL ELECTRICAL MANUFACTURERS ' <br /> ASSOCIATION <br /> NIC NOT IN CONTRACT <br /> OFC OPTICAL FIBER CABLE <br /> . . � , <br /> OFCI OWNER-FURNISHED CONTRACTOR-INSTALLED , <br /> OFOt OWNER-FURNISHED OWNER-INSTALLED <br /> PRINCIPAL IN CHARGE:� <br /> PROJECT MANAGER: � <br /> OSP OUTSIDE PLANT PROJECT ARCHITECT: � � <br /> JOB GAPTAIN: � • � <br /> A A <br /> � . � , <br /> Electrical General � <br /> Notes & Abbreviations <br /> � . . . . - <br /> - <br /> 1 . ; <br /> 1 2 3 4 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.