Laserfiche WebLink
� � �. <br /> BAKERY <br /> PROVIDE PRV CASH ACME MODEL E8-45. SET PRESSURE TO 15 PSI. � � ,t� <br /> 150" SINK FURNISHED WITH: U <br /> \ � <br /> �� � - FAUCETS „ � <br /> 24" 24 24" 24" 24 24� - LEVER WASTES 3/4 STUB-OUT WALL PROVIDE PRESSURE GAUGE DWYER MODEL �j � <br /> BAKERY: SLOPE FLOOR� 1%� CONCRETE FLOOR 2� 2�� 2� PLUMBING ROUGH IN: W/ESCUTCHEON #SGB-00521 N (0-100 PSI) f�, Q � <br /> I�-� � <br /> FOR A DIAMETER OF 8 -Q . CHS FROM CHILLED WATER LINE. <br /> CENTRIFUGAL EXHAUST FOOD SERVICE: SLOPE FLOOR TOPPING PER " _ � - - - �A 1/2"HW BALL VALVE & NON p � x � <br /> FAN, SEE SCHEDULE 1� FOR A DIAMETER OF 4'-0". ARCH. DWG S �� 3�4^ SLAM CHECK VALVE �+t 6 H � �6 � �W z � <br /> ALL OTHER: NO SLOPE. „ , Q 1/2"CW BALL VALVE & NON c� '� <br /> FAN BASE FIN. FLOOR p 35-1/2 �� � � <br /> HINGE KIT 30 ' SLAM CHECK VALVE �+16 <br /> ��2" BALL VALVE BALL VALVE, STRAINER � �9 0 ��y� <br /> i (SOIC) ' ,- ;, ; : QC (2)MY-2, MIXING WHA AND CHECK VALVES � ' °°`�`�°°°°°��o <br /> GREASE TROUGH I _ _ _ 48"• - <br /> _._ . ._ . . � ` . <br /> rt a _.._ .. � : . _ _ VA�VES �+ STRAINER i <br /> __..___ <br /> - - PROVIDED WITH UNIT. � �/�°°°������ >�s��1- <br /> �� (SOIC) ! / c. ..__... .... , _._.. _._- \ M.0 T0 PROViDE WARNING PLAN VIEW z6 O / " FOR � <br /> _ _ __ _ . __ _ <br /> 0 3 4' TEMPERED WATER CHECK VALVE � °�� ����', <br /> T � i HB-2 C�D+16 <br /> SIGN READING CAUTION �� <br /> SEE DETAIL � �� �� ��2 SINK FURNISHED WITH: Y ��� ,(�ro�\ ��o� f <br /> : � a ` �` ° p DETERGENT PACKAGE. 18' X 18 X 3 4 � <br /> - . 140`F I�OT WATER" � GOOSENE�K SPOUT KNEE OR � ��_;� � 3 ��g O � <br /> ---- ,. <br /> � PLYWOOD BRCKING � <br /> °0,0 i �, <br /> IN. 40 DISCHARGE i �� .. <br /> M I I � E 3 4 TE�;�PERED WATER � � � �o� � <br /> _ . _._ _ _ _ _ __ __ O � � BEHIND WALL BY FOOT VALVES 1-1/2 WASTE r, Z ��qo��,�� <br /> � THREAuED HALF �, . 4"� THREADED WALL FLASHING �� E-5 -' �°?�' <br /> � i � HB-2 �+16 FQR MECHANI�AL TAILPIECE iNALL BR�CKET OR i-�-i � °�Wo oo�°° � _ <br /> PROVIDE HASP WITH �! ; COUPLIN� WITH Tt�,�P -- AD,.USTABLE HELGHT Sl' OT11�RS, i i SOAP DISPENSER. PEDESTAL � �" ����� <br /> COTTER PIN TO SE�URE �'�� �T�H FRIMER CONNECTION OUTLET WITH INTEGRAL SURFAGE MOUNTED ��,� � � i „ T CONTR,4CTOR. � n "L,�,�,�,�, <br /> BUTTEhFLY LOCK. HQSF EY VENDQR __ _ _� _� _ _ _ __ _ _. _ ; Q � _ ' i ,, <br /> i i F 1 2 TEM P£R ED WA,ER <br /> OPEN ENO OF HINGED _ _-- �__._ . _ � � ��-__ _ i i t,ON i iNUE TO HB-2 2X4 BLOCKING 84 � T� <br /> F A N (T Y P O F 2) II,, t ; ���� � � s���� � � N E R R P A f� W A S'r if R. IN WALL �� � <br /> ._�_ _._.�_ ., �. i i i � <br /> _._ : �: � -_ _ <br /> �ROOF DECK �r ,_ ___ _.�e ..��.�� ___ �_ � _._ _ � _ .�__� __ _ i i MBING . �� I—f � � .� <br /> Fa �� PLU ROUGH IN• ' <br /> SEE SCHEDULE FOR � �, I � � � � ' � ��� <br /> UIRED ` ; s� t i ��2,.� E-1 � 60� �1/2 HW WALL STOP �+i 6 , � , , <br /> MINIMUM REQ i <br /> CURB HEIGHT AND '�--0UCT MATERIAL PER ��� �✓��� �.u�� - - <br /> ._.<� 1 _ __ _ <br /> � F�- - -=- - = -- " D --i O O 1�7" CW WALL STOP �+16" <br /> SUPPLIER i j OTHER DETA{L �� �—P-TRAP & TRAP ARM ' _ __ ; �-� Y � �,i � �� __= ry ; �=�Ft PIPiNG W1THW WALL C 36" :CQ1-1/2" WASTE �20" ' <br /> , <br /> , <br /> ._: _ __� ; , <br /> -�� �_ ! <br /> ! ! <br /> NOTE: i <br /> EXTEND DUCT UP 4 P-TRAP� ;' � A B M �� A B A 8 E : A B , <br /> MINIMllM 40" DISCHARGE FROM ROOF � TO FAN INLET AND : _; 1 kfilN. ` <br /> ' EXTERIOR BASE OF WASTE Mi�NIFOLD AIR GAp (TYp.) INDIRE�T DRA4N � � ' <br /> GREASE TRAP HINGE KI , AN Ji I <br /> DECK FOR UL 762 FANS. TOP CURB BY CO(vTRACTOR. VIR FLOOf2 SINK ' <br /> � <br /> FLOOR DRAIN TYPE D- 1 FOUR �OMPARTMENT SINK E- 22 WATER METER E- 5 �IAND SINK E- 1 <br /> RO 0 F EXHAUS T FAN � 1 5��: No�� 4� SCAi�E: NONE 5 a � <br /> 1 � SCALE: NONE <br /> SCALE: NONE ' ' <br /> PROVIDE SS BIRD —� 8"� STEAM VENT. CENTROTHERM INN�FLUE <br /> SCREEN AND RAIN SINGLE iNALL OR SCHEDULE 80 CPVC. 4"� FLUE THRU 23 EXHAUST FAN Q HINGE , <br /> CAP AT TERMINATION. PROVIDED BY M.C. RQOF. SEE DET�41L M TER��IINATlON SHALL <br /> S-5 CLAMPS, SUPPLIED DISCHARGE A MIN. <br /> AND If�ISTALLED 8Y M.C. ' TALL CONE ROOf METALBESTOS CT OF 40� AB�?VE RO�F. RQOFi�FIELDN QN <br /> FLASHING, ROQF _ RAIN CAP — — � <br /> PENETRATIONS BY � `-- 4°4� FLU� THRU ROOF 4"� FLUE � � ROOF I I VERIFY <br /> ��I M.C. COORDINATE � <br /> STANDING SEAMS ;r THRU ROOF OFFSET 10' MIN. FROM <br /> REQUIREMENTS PROVIDE SUPPORT FOR , <br /> WITH MBS. PARAPET. LOCATE �JFFSET ABOVE STEAM VENT FROM ROOF � ' <br /> � �, CEILING. DUCT CONTINUOUS THRU PROVIQE VERTICAL SUP�ORT <br /> STRUCTURE ASSEMBLIES PER Q � <br /> � STEAM VENT, ROOF W/FLASHING & RAIN CAP. VIDE ESCUTCHEONS MANUFACTURER'S INSTRUCTIONS. ' ' <br /> � PRO <br /> ' CENTROTHERM, 8"�b FOR ALL CEILING CEILING 12 � I o � <br /> 12 GA GALVANIZED " ' <br /> i STEEL WIRE(TYPICAL)I, ' ;' ' I I CEILING PENETRATIONS GALVANIZED DUCT CAPPED 12"� TEE FOR N <br /> : CENTROTHERM CEILING. > <br /> � I i ��' �/ � � � COMMERGIAL APPLIANCE �UTURE CONNECTION. � <br /> i � I � <br /> � STEAM VENT FAN. ADAPTOR WITH VIBRATION CAP 10" DUCT HERE FOR FUTURE <br /> PROVIDE 3 4" TEE SUPPLIED BY OWNER ISOLATtON BOOT �� OVEN. SEE PLANS FOR LOCATIOPI. � � <br /> � LVO INSTALLED BY M.C. P-TRAP �0 � STAINLESS STEE � DUCT BELOW , <br /> CAP WITH DRAIN DRAFT DIVERTER I <br /> � <br /> I ; ' ', <br /> � <br /> FROM STEAM VENT. MANUFACTURING __ . <br /> - PROVIDED BY OWNER STAINLESS STEEL SLEEVE CEILING. <br /> �I INSTALLED BY M.C. , <br /> I � ' FOR 10"�b BAKERY OVEN CEILING <br /> i� <br /> NOTE: EXHAUST THROUGH CEILING. RISER I <br /> I <br /> I . <br /> � CONNEC i S-5 CLAMPS ON M.C. TO PROVIDE AND INSTALL ALL. <br /> . _._ - <br /> NEAREST STANDING SEAM SO ,; DAYLIGHT CONDENSATE ' FLUE/VENT PIPWG COUPLINGS, 18 GAUGE STAINLESS STEEL > <br /> ' ' AN �; " ' FITTWGS, SUPPORTS BRACING EXHAUST HOOD W/ WELDED FILTER �; � <br /> . DIM L IS GREATER TH DRAIN LINE 2 PW PIT � <br /> DIM 'H' � ' � ROOF CAPS AND DECK TITES SEAMS. �:; � <br /> __ _ w <br /> ' � , ' <br /> j I, _ _ - _ _ OTE • CONTRACTOR TO ' o '. . <br /> ELEVATION VIEW VERIFY CONNECTIONS <br /> P�a,N viEw ' RAC K WAS HE R E— 6 SIDE viEw QA EXHAUST FAN CONTROLLED BY OVEN. W TD TMANUFACTURIORS � <br /> SCALE: NONE � 1 OB PROVIDE 4" STAINLESS STEEL BASE SHOE <br /> W/ BEVELED BOTTOM EDGE ALONG THE � N _� <br /> � <br /> INSTALL ON ALL FLUES TALLER THAN 3' ABOVE SCREENED 180' BOTTOM OF PROOF BOX THAT COMPLIES � <br /> WITH LOCAL HEALTH CODES. I N � <br /> ROOF DECK. INSTALL A MINIMUM OF THREE VENT ABOVE ROOF , <br /> Y SPACED SUPPORT WIRES. —� o \ , <br /> N N <br /> EVENL � ' GAS REGULATOR QC PROVIDE STAINLESS STEEL CLOSURE � � Y a <br /> ACCESSIBLE WHq � PANEL AT OVEN SIDE OF PROOF BOX m � <br /> w o <br /> METALBESTOS--- n—�GAS �ROOF ABOVE CEILING. ROOF AND AT REAR OF PROOF BOX. � <br /> RAIN CAP BALANCING VALVE �--�HWC SIZE PER w <br /> 6" �HW PROVIDE CAPPED TESTING Hw�p�qN B w <br /> MqX TEE. MINIMUM LENGTH 10 FLOOR N <br /> PIPE DIAMETERS FROM PRV <br /> FINISHED WALL�� i CEILING INTAKE AND OUTLET � CEILING SIDE ELEVATION Q <br /> PROVIDE ESCUTCHEONS FOR � (`� <br /> �'� PROVIDE SIGHT FLOW ALL CEILING PENETRATIONS <br /> � I FACTORY WELDED "V�� CLAMP TO BE PROVIDED <br /> NON-HAROENING w <br /> � � INDICATOR. M/N: W.E. � <br /> CAULK ANDERSON SFI-10aMP I T'STAT PROVIDE THRUST BLOC � LONGITUDINAL SEAM. �BY DUCTWORK MANUFACTURER. cNn <br /> i AT END OF P RUN � � <br /> • �� H „ PER OETAIL �p � � <br /> �ECK TITE 1 HW TO PAN � <br /> � OBTAINED WASHER P DUCT FLANGE. SEAL WITH 3M FIRE � <br /> HIGH TEMP SILICONE � <br /> FROM M8S CONTRACTOR TO INSTALL DROP PIPE FROM CEILING NOTE• <br /> BARRIER 2000+ A � � � <br /> M.C. TO PROVIDE AND SEALANT. Q � � � <br /> S-5 CLAMP � ` 1/2" BALL VALVE TENANT SUPPLIED HOSE SPACE WITHIN 6" OF INSTALL ALL• � � � p <br /> `, DOWNSTREAM OF BACK OF WASHER. DUCT CONNECTION <br /> BACKFLOW PREVENTER FIXTURES, PIPE, FITTINGS NOTES: � <br /> , BACKFLOW PREVENTER i HOSE REEL, SPRAY NOZZLE �i AND VALVES UNLESS • � <br /> 1 DUCTWORK FLUES SHALL RUN STRAIGHT FROM EQUIPMENT TO ARCHITECTURAL FINISH WITH NO V W � � <br /> y 2" MIN. CLEAR�' � ��2" WATTS 007QT � TO HOSE REEL AND HOSE HANGER � OFFSETS. M KE OFFSETS WITH FITTINGS ABOVE CEILINGS, BEHIND WALLS OR IN ROOF STRUCTURE � y p � � � _ <br /> OTHERWISE NOTED. <br /> � - � � S U P P L I E D B Y TENANT WITH AS SMALL AN ANGLE OF OFFSET AS POSSIBLE. G.C. TO COORDINA T E TH E L O C A T I O N O F � a C�2 � <br /> � � �� � INSTALLED BY CONTRACTOR SPRINKLER HEADS SO THAT THEY ARE NOT IN CONFLICT WITH THE VENT DUCTWORK. �z •• �' <br /> 1/2 GAS CONNECTION , �� ' <br /> ,: OO CEILING CLOSURE TO PAN WASHER � �— FINISHED WALL PROVIDE STAINLESS STEEL DUCT BELOW CEILING AND GALVANIZED DUCT ABOVE CEILING. : � W <br /> . z � �, z <br /> � SEE EQUIPMENT OETAIL I 2) EXHAUST DUCT TO BE FACTORY BUILT BY CAPTIVEAIRE. SEE SPEC 233800 FOR ORDERING. <br /> PLATE D-1 FLOOR � � PROVIDE NON-CORRUGATED CONTACT: ATTN: COSTCO PROJECT MANAGER � (425)212-5996 OR REG85�CAPTIVEAIRE.COM w � � W x � <br /> � FOR SPECIFICATION ----, <br /> t <br /> E L E V A T I O N V IE W D R A I N. S E E P L A N _ , 4 A G A A P P R O V E D F L E X I B L E G A S ,.. , 3) A L T E R N A T I V E: N O R D F A B Q U I C K F I T 2 2 G A U G E G A L V A N I Z E D E"'� c O U 1 G� 0.� f� <br /> ;� FOR LOCATION -- REAR ELEVATION VIEW HOSE FOR GAS CONNECTION SIDE VIEW � 4 OTHER ALTERNATIVE DUCT TO BE APPROVED BY MECHANICAL ENGINEER. <br /> ,, O l DIM 'L' TO 8E GREATER THAN DIM 'H' �� <br /> � 5� A L L D U C T S T O H A V E W E L D E D L O N G I T U D I N A L S E A M S A N D C L A M P L O C K S. <br /> � FLUE & VENT ; <br /> — OVEN DETAIL E— '7 � <br /> � TIE DO WN DETAIL <br /> RACK WASHER E 6 � <br /> 4� SCALE: NONE � � ` `� i � <br /> � 3 � � � <br /> � SCALE: NONE SCALE: NONE <br /> � � � <br /> r z <br /> � FLOOR SINK �2� w � <br /> ,� � � � � <br /> � REF. DRAIN SIZE z <br /> � D-4 4" ,��: CONTRACTOR TO PROVIDE w� � <br /> O „ 12X12 WALL ACCESS PANEL. q Q O <br /> �-� 2 LOCATION TO MATCH SINK <br /> w <br /> � <br /> �: w <br /> � D-4 4" DETAILS. � r, <br /> " � � W <br /> x O <br /> � B D-7 3" A 12 w � <br /> � Q � <br /> k PROVIDE 1" MIN. NR GAP OO O O � <br /> O <br /> FINISH FLOOR C B Q �j � w � <br /> � _. �� � <br /> � _� (TYP.) A BO PLUMBING ROUGH IN � SINKS: T � <br /> A 8 WALL RCCESS PANEL q 3 4" HW WALL STOP �+48" v <br /> RIM SET FLUSH ACUDOR #UF-5000-SCS j O � <br /> �-�, w � � <br /> : PIPING WITHIN WALL , � � `2� ` <br /> k QB 3/4" CW WALL STOP �+48' � <br /> � DISPLAY CASE ---DETERGENT PKG. <br /> 24" MIN FOR PROVIDE OFFSET AS C MIXING VALVE <br /> DRAINS REQUIRiNG REQUIRED TO LOCATE DRAIN BY OTHERS MATCH O � � � [--i <br /> , BLOCK OUT SEE 1/2 EXPOSED COORDINATE I � LOCATION WITH MV-2 �+48" <br /> PLAN FOR IOCAl10N WITH REFRIGERATION SINK DET�IILS 0 Op 3/4" TEMPERED WATER <br /> � p� w � W <br /> CONTRACTOR FOR FINAL � � �-�SURFACE �2� HB-2 �+16 � Z ' w � `� �i <br /> L O C A T I O N � M O U N T E D F O R S O A P D I S P E N S E R - <br /> - I O (WASH COMPARTMFNT) <br /> - i� E 3 4�� TEMPERED WATER o ~ � � � w <br /> � O HB-2 C�+16" a o � p <br /> � � � THREADED QD FOR SOAP DISPENSER <br /> FLOOR SINK HALF EXPOSED ADJUSTABLE �o-� (SANITIZING COMPARTMENT) � z � <br /> HEIGHT OUTLET. ~T R A P & A R M �--�� SIDE VIEW o z <br /> � w <br /> ELEVATION SEE TABLE FOR SlZEOg -- _--�-__ __ ___ _ _ --------_ _- --_- - <br /> S�zE O V�ALL ACCESS MIXING VALVE DETAIL � _ .- � � <br /> � U � <br /> W <br /> FLOOR SINK D— 4, D— 7 E- 18 & E— 22 � w <br /> wc � <br /> m � <br /> SCALE: NONE � � <br /> SCALE: NONE � y- �� <br /> ¢ � -� <br /> � � o � <br /> � � <br /> . zd � <br /> � w � <br /> � _ �� U � <br /> � � � � g � <br /> N O y�� <br /> _ <br /> , � � . �'.�',� . <br /> � <br /> rr^ � t <br /> V l` O � � <br /> V � � � � <br /> 7t, '3, '�+! <br /> � n- z �` �� <br /> � o � �� <br /> zo <br /> � � �„_. �:�,,, ,���z _.,_ <br /> � <br /> � <br /> Q <br /> � <br /> � � <br /> 0 <br /> ,n ., _ <br /> I <br /> � � <br /> � <br /> I--� O <br /> H Z �� � <br /> � U <br /> W <br /> W � <br /> 0 <br /> Q � .�:�.,.�{_��,��fr . ��..:. <br /> a <br />