Laserfiche WebLink
FRAMING NOTES <br /> Check areas where plumbing may cause problems, such <br /> as toilet flanges centered on joists, plumbing walis, etc. � <br /> Positive connections at post to pads, post to beams, etc. 4 <br /> A <br /> FIREBLOCKING <br /> Purpose to cut off concealed draft openings. } <br /> Req'd locations- in walls vert. at cig and flr levels, horiz. max 10ft. � <br /> Intersect. of concealed vert./horiz. spaces(e.g. soffits). <br /> Concealed spaces btwn stair stringers, top& bott of run. GUTTER <br /> Openings around vents, ducts, pipes&cables at cigs.&flrs. z <br /> � — - - = — _—��_..--__--..----___—.—___�_—..___-- -= — — <br /> ___..__ ___._ _._� — — <br /> In space btwn chimneys&combust. frm'g. <br /> N -F-�O � � <br /> DRAFTSTOPPING \ 4x10Hf2 4x10Hf2 4x8Hf2 � �,'�' / � � <br /> Req'd at flr/clg assemblies to limit concealed space to 1000SF for - - - - � � <br /> � - �� I �-- -- � w <br /> suspended clgs or open web trusses. il \ � Q <br /> l \ ° � ' I O <br /> — � � � ( \Q ,, _ �j z <br /> ROOF FRAMING NOTES — � �, �' <br /> 1. The contractor shall verify all notes, dimensions&conditions prior � a \ � U' � I! <br /> � — � N �° I r� <br /> to construction. �I \ _ � � � � I II � <br /> 2.Ail Headers shall be 4x8Hf2 w/(2)2x Posts, U.N.O. \ � � <br /> `�, � o � RIDGE '' � � o �i � � <br /> 3. Provide vented blocking over exterior walis&full depth, sotid �� \ � p N —� �_ __ i.. <br /> blocking at interior wall supports. {� ti� � ° �' _ � Ij � o � <br /> o O� w � X <br /> 4. Bearing Walls are shaded. A W � � � �`` 'yj � I' N W N N <br /> 5. Indicates point load supported by 2-2x U.N.O. � �� � _ _ �' � L'� � ``� A � � Z � �' <br /> � ��' �� - <br /> 6. Install Shear Wall and/or blocking roof structure before � E �� � ����°'• a � � r li c� a Q � <br /> installing finish roofing. �I � ��Q �"Q t � �� } � .� � o <br /> 7.ALL TRUSSES: i I � = <br /> -Shall carry Manufacturer's Stamp. � ';� i o O � <br /> rRtf7�E,� � � �i a � � °' 'm <br /> -Shall be installed & braced per Mfrs. specifications. I I ° o �, � i '°. � � � � <br /> -Shall have design details&drawings on site for framing inspection. �� `r I I'� � �"' � ! y � � � � <br /> -Shall not be field altered without prior bldg. dept. approval of � <br /> � "- C� '' r' � f- � �' O c� <br /> � � � � �� � � � ��sr �� , ��� � � � � � <br /> _ _. <br /> engineers calculations. W � �Q � —� <br /> -Truss hangers shall be specified by the truss engineer. � � � • � � � \ I� `n W � <br /> l ' � � , — `—�; � � <br /> \, 0 / <br /> i� � I � a RIDGE I I �'i,o - - - �_ _ .._ Z a� <br /> ROF DRAINAGE & COVERING I .-,.� .__ -___� ___ ,�_ __ ___. ._.. �_ _._. ._._�`'F � �� ,� N I� � � <br /> O � '� <br /> 1. Water shall discharge to an approved drainage system. � � � ~'� � 9<<� I I 5~' o Ii <br /> 2. Flashing shall be installed at wali&roof intersections, at changes in � °`` F � � ��� � ' � � � � �4 <br /> roof slope or direction, around roof openings. 4 �I � � <br /> , Q ' � � � � �� � I I <br /> 3. Flashing against vertical front wall, as well as soil stack, vent pipe, �) x n.. .��%`� <br /> valleys, and chimney shall be applied according to the asphalt shingle I tij'o = z � I <br /> _ ''� ' � � I� o <br /> mfr. printed instructions � �r'� �` <br /> 4. Drip Edge shall be provided at eaves and gables of shingle roofs. � °° li � � <br /> ., I � I <br /> Underlayment shall be installed over the drip edge along eaves and �I � .# � � <br /> _.___ � <br /> under the underlayment on gables. Unless specified differently by the �� � � ¢ <br /> r shin les are ermitted to be flush with the dri edge. � I� � '� I� � <br /> roofing manufacture , g p P � �-- -; p LSTA24 � � <br /> : `� \ �i � "_' <br /> I ' � <br /> a� <br /> � � '� � '���, � �..—�._, Q � � <br /> TION � �' w <br /> TI LA <br /> ROOF VEN l � � <br /> SECTION R806 iI / ` `� I � <br /> R806.1 Ventilation required. �I / I �o=o �yf O � � <br /> Enclosed attics and enclosed rafter spaces formed where ceilings are � �.� x I � � w <br /> ! I � �� �' � N Q <br /> applied directly to the underside of roof rafters shail have cross ventilation � , �� . I � O L <br /> for each separate space by ventilating openings protected against the � , �' <br /> entrance of rain or snow. ''� � ' � + � "-� O N <br /> �o �, <br /> Ventilation openings shall have a least dimension of 1l16"min. and 1/4"max. ; `L"L �, II Q `� <br /> Required ventilation openings shall open directly to the outside air. � '�f � �� <br /> ~ o <br /> R806.3 Vent and insulation clearance. Where eave or cornice vents are ' ` � - - � ' � <br /> w <br /> installed, insulation shall not block the free flow of air.A minimum o f a 1" � 92*-2X6 4x10Hf2 4x 1 0 H f 2 I � <br /> space shall be provided between the insulation and the roof sheathing � TYP \ � <br /> and at the location of the vent. � - - \� <br /> THIS WALL LINE: <br /> Dbl. Cont. Top Plate <br /> 4' min. Splice with SIMPSON HARDWARE <br /> 20- 16d Nails Per Lap. z <br /> 'ROOF VENT CALCS: � Q <br /> IRC R806.2., Provide Cross Ventilation. HD3= Simpson MSTI 36 � <br /> 1072sf/300= 3.6sf Required HD4= S'impson LSTA24 a w <br /> (to tie SW to frm'g/blk'g) a � <br /> Upper Roof Area (40-50%of req'd) �! N <br /> 289sq. in. (48 sq. each) � �Z <br /> VentSure Metal Slant Back Vent-6 provided R O O F F RA M I N G P A N� S �_-� � _ <br /> , Exhaust NFVA(near ridge of roof) � W O <br /> _ ~ = W <br /> 1/4" - 1 '-0" <br /> Lower Roof Area W � � <br /> Bird block per hole factor 1�� _ .0055 NOTE: ROOF FRAMING DESIGN BY TRUSS COMPANY <br /> w <br /> 142' x.0123 (1.5" dia)x 3/block = 5.2sf � ) �' <br /> ,.� � 6 � <br /> -��.�-�3 TI� DA�TE: <br /> � �'��w�sN� �� <br /> �.. ��... �. <br /> � ` '� �;.; 12/30/2018 <br /> €+; �� <br /> , �-��' � � � SG,�LE: <br /> r. <br /> - � <br /> ;� ;.,. ��=/�� �,��`G � <br /> �'1'ro��..��"'' <br /> �'���� �� � <br /> � SHEET: <br /> A4.5 <br />