My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2 W CASINO RD 2003 CABANA 2018-01-02 MF Import
>
Address Records
>
W CASINO RD
>
2
>
CABANA
>
2 W CASINO RD 2003 CABANA 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2020 11:15:57 AM
Creation date
2/20/2020 11:13:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2
Tenant Name
CABANA
Year
2003
Notes
EMERALD APTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( ( <br /> PUBL/C WO«K5' <br /> �� <br /> September 28, 2001 <br /> Gary Burchard <br /> 9709 S. 203"' Street <br /> Kent, WA 98031 <br /> RE: Owner: Yuksel, Inc. <br /> Job Address: 2 W. Casino <br /> Plan Check No: C0109-016 <br /> Dear Mr. Burchard: <br /> [n response to your application for a construction permit, your plans have been <br /> examined and you are advised that the issuance of a permit is bemg withlield for <br /> the reasons listed below. These comments address building issues only, additional <br /> revisions or additions may be required by other departments (such as Utilities, <br /> Planning or Fire). All references refer to the 1997 Uniform Building Code, as <br /> amended by the State of Washington and/or Washington State Energy Code 2001 <br /> Editiun, unless stated otherwise. <br /> In order for the processinp of your application to continue, it will be <br /> necessary to provide the Bu�lding Division with two complete new sets of <br /> drawings retlectmg the corrections requested. <br /> 1. The upper Floor framing plan indicates 2 x 12's at 16" o.c., HFN2, which <br /> do not t"igure for the 20-ft. span supporting a 40 psf live load plus a 10 psf <br /> deadload. <br /> 2. Thc walls supporting the one-hour horizontal occupancy se aration are <br /> required to be of one-hour fire-resistive construction per UBC :�02.2. <br /> 3. Gypsum wal!board is not allowed to be instaUed on exterior surfaces. UBC <br /> 251 l. l. Gypsum sheathing :s a�.ceptable. <br /> 4. Safery glass should be eueriticd at thc interior window adjacent to the <br /> vestibule door. UBC 240ti.4. <br /> 5. The plans sheuld indica�.e guttcrs :'.,�wing te the storm sewer. <br /> 6. The shuwer compartments will be required to comply exacdy with the <br /> requircments of UBC I IOG. I 1.10, state amendments. The plans should <br /> indicate these reyuirements. <br /> �L <br /> CITY UF EVERETT• 3200 Cedar Street • Everett.WA 98201 • (425) 251-8800• Fax(425)257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.