BLOWER DOOR-TEST RESULTS <br /> Lr <br /> Blower=Door TstingNW Date of Test: _ ® <br /> _ __r--4Z 3I :com___. ec nician Name• — ---=---- <br /> blowerdoorschedul <br /> ;grnalCcom <br /> Job Site Information <br /> Permit#: <br /> Address and Lot Number: �/ ��' _ "-'' �— S` �r► s —j <br /> City: '' I gi ° ' et�Z 0 <br /> Zip Code: <br /> Cond. Floor Area(ft2): 9-30,/ Age of House: <br /> Source(check one): Plans ❑Esti :ed,. 'asured <br /> Test Results <br /> Pass ❑Fail ❑Could Not Complete tic q-70 Volume <br /> ,ACH50 <br /> Test Target (.5`• �) 7Z CFM@5OPa <br /> Ring(check one if applicable): ❑Open ❑A ❑C <br /> Blower Door Fan Location: .,440" 4114 Weather Conditions. <br /> Results shall be reported as Air Changes per Hour at 50 Pascals if( H50 and shall be calculated as follows: <br /> ACH50=(CFM50 x 60)/Volume <br /> Where: <br /> CFM50=Blower door fan flow at 50 Pascal pressure difference <br /> Volume=Conditioned Floor Area of the housing unit x ceiling height <br /> 2015 Washington State Energy Code reference: <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour.Testing shall be conducted with a blower <br /> door at a pressure of 0.2 inches.w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approvedthird party.A written report of the results of the test shall <br /> besigned by the party conducting the test and provided to the code official.Testing shall be performed atanytime after creation of all penetrations of the building thermal envelope.Once <br /> visual inspection has confirmed sealing(see Table R402.4.1.1),operable windows and doors manufactured by small business shall be permitted to be sealed off atthe frame prior to the test. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not.sealed,beyond the intended weatherstripping or other infiltration control measures; <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intendedinfiltration control'measures; <br /> 3.Interior doors,if installed at the time of the test,shall beopen,access hatches to conditioned crawl spaces and conditioned attics shall be open; <br /> 4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systerns,.if installed at the time of the test,shall be turned off;and <br /> 6:Supply and return registers;if installed at the time of the test,shall be fully open. <br />