Laserfiche WebLink
House G avaje(a,3205 16th St., Everett, ill 198201 <br /> al <br /> Samples taken are listed with their corresponding analyses.If asbestos is detected,those samples containing asbestos are listed first <br /> and noted with the initials"ACM". <br /> Some sample analyses listed maybe a representative analysis of individual and separate samplings and analysisof homogenous <br /> materials,as prescribed by A.H.E.R.A.guideline. <br /> If,during demolition or renovation,any additional suspect asbestos containing materials are located[may include but not limited to: <br /> sheet vinyl flooring;tile flooring,wall or ceiling texturings or paints,concrete siding or skirting,cement pipes,cement wallboard, <br /> electrical cloth,electrical wiring insulation,thermal paper,wallboard,joint compounds,vinyl wall coverings,spackling compounds,or <br /> any other suspect TSI(Thermal System Insulation)),those materials are presumed Asbestos Containing Materials unless determined <br /> to be non-asbestos by laboratory analysis. <br /> Asbesto-Test,Inc.does not guarantee approximations of quantities of ACM, which may be listed with the analyses.It is therefore <br /> recommended professional abatement price and/or disposal quotesbe obtained by inquiring as to fees per area of specific ACM <br /> material(i.e.square or linear foot,etc.),or by on site assessment. <br /> Any and all materials identified as ACM and/or PACM in this report must be abated prior to disturbance in renovation or demolition. <br /> PLM(polarized light microscopy)has been known to miss asbestos in small percentages of some samples,which contain asbestos, <br /> thus negative PLM results cannot be guaranteed. Floor tiles and wipes should be tested with SEM(scanning electron microscope)or <br /> TEM(transmitting electron microscope),to insure analytical accuracy when asbestos is reported in small percentages <br /> Analytical test method:USEPA 600/R93/116**(PLM);WAC296-62-07753 App.J <br /> **One percent is the USEPA regulatory limit for asbestos in bulk samples. <br /> Key: "FRIABLE'signifies"Easily Airborne" <br /> ACM signifies"Asbestos Containing Material" <br /> PACM signifies"Presumed Asbestos Containing Material" <br /> CAB signifies"Concrete Asbestos Board" <br /> < signifies"less than" <br /> TSI signifies"Thermal System insulation" <br /> HVAC signifies'Heating Ventilating Air-Conditioning" <br /> NAD signifies"No Asbestos Detected" <br /> END OF REPORT <br /> ArLynn Hammond,.Pres., BSc. <br /> Analytical Chemist, AIHA proficient ,, <br /> Inspector, certified A.H.E.R.A. <br /> accred.#168598 (Expires July 18, 2019) <br /> ,,a <br />