My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2405 COLBY AVE 2019 Plans 2022-11-28
>
Address Records
>
COLBY AVE
>
2405
>
Plans
>
2405 COLBY AVE 2019 Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 7:52:34 AM
Creation date
3/6/2020 11:17:22 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2405
Permit
B1904-005
Year
2019
Notes
EVERETT HIGH VOCATIONAL - TI REMOVAL REPLACEMENT OF INTERIOR FINISHES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 <br /> TELECOMMUNICATIONS R.OUC�H-IN SCHEDUL� INT'E�C�Il� CLO�K ROIJGH-IN ��HEDIJL� <br /> OU7LET �OX CONDUIT OUTLET BOX CONDUIT <br /> SYMBOL MOUNTING HEIGHT DEVICE NAME (,ZTY SIZE QTY SIZE TERM LOCATI�N �UD RING DETAIL NOTES SYMBOL MOUNTING HEIGHT DEVICE NAME �.� g�Z� QTY SiZE `T�RM LOCAT'ION MUC� RING DETAii� NOTES <br /> � STANDARD, UON CATEGORY 6 DEVICE 1 4-11/16" 1 1" ACCESSIBLE CLG SINGLE GANG 1/E8.02 - —fl +96" ANALOG CLOCK 1 4"S 1 3!4" ACCESSIBLE CLG DOUBLE GANG 3 � � <br /> �� ABOVE COUNTER CATEGORY 6 DEVICE 1 4-11/16" 1 1° ACCESSIBLE CLG SINGLE GANG 1/E8.02 3 � CEILING INTERCOM SPEAKER 1 SPECI BLOTX BACK 1 3/4" ACCESSIBLE CLG - 2 � � <br /> o . <br /> AS NOTED CATEGORY 6 AV DEVICE 1 4-11/16" 1 1" ACCESSIBLE CLG SINGLE GANG 1/E8.02 4 GENERAL NOTE: MOUNTWG HEIGHTS INDICATED ON THE SCHEDULE REFER TO CENTER OF BACK BOX. <br /> �� NOTE 1: DEVICE REQUIRES NETWORK CONNECTION, PROVIDE CATEGORY 6 CABLING (CABLING BY 271100). <br /> I�J ABOVE CLG CATEGORY 6A WAP DEVICE 1 4-11/16" 1 1" ACCESSIBLE CLG SWGLE GANG 2/E8.02 1 NOTE 2: CODUIT ROUGH-IN IS ONLY REQUIRED WHERE SPEAKER IS LOCATED IN AN UNACCESSIBLE CEILWG SPACE. . - . - - � - <br /> AP NOTE 3: PROVIDE WiRE GUARD WHEN LOCATED fN GYMNASIUM OR MULTIPURPOSE ROOM. ' ' • • •• ' '� ' <br /> GENERAL NOTE: MOUNTING HEIGHTS INDICATED ON THE SCHEDULE REFER TO CENTER OF BACK BOX. NOTE 4: SINGLE GANG MASONRY BACK BOXES ARE ACCEPTABLE FOR EXTERIOR MOUNTED DEVICES. <br /> E NOTE 1: PROVIDE ROUGH-IN FOR HARD-LID AND OPEN TO STRUCTURE CEILINGS. MOUNT FLUSH IN HARD-LID CEILINGS AND SURFACE MOUNT IN OPEN TO STRUCTURE CEILING. E <br /> NOTE 2: FLOOR BOX DEVICES LOCATED ON THE FIRST FLOOR SHALL ROUTE TO THE NEAREST TELECOM ROOM OR AS INDICATED ON THE FLOOR PLANS. • , <br /> NOTE 3: MOUNT DEVICE ABOVE COUNTER TO MATCH ELECTRICAL RECEPTACLES. <br /> NOTE 4: TERMINATE CATEGORY 6 CABLING ON IOT PATCH PANEL. <br /> � ' S <br /> �'+� /� �+�p��1�A /\ 1 I�I� \/I�1 1 A 1 ����LA�'� ��1J��1 11 � Hargis Engineers, Inc. <br /> \.r�/`1�7 I"� 1 Y 1 /•1 V V `,J/���\L �l i-7 �J L� <br /> 1201 Third Avenue, Suite 600 <br /> OUTLET BOX CONDUIT Seattle, WA 98101 <br /> SYMBOL MOUNTING HEIGHT DEVICE NAME MUD RING DETAIL NOT�S <br /> QTY SIZE QTY SIZE TERM LOCATION <br /> t( 206.448.3376 <br /> f� 206.448.4450 <br /> HDMI, VGA W/AUDIO 1 4-11/16" 1 1" ACCESSIBLE CLG DOUBLE GANG 1/E8.03 2, 3 w � hargis.biz <br /> av STANDARD <br /> � USB 1 4-11/16" 1 1" ACCESSIBLE CLG SINGLE GANG 1/E8.03 - <br /> cP +44" AV CONTROLLER 1 5° 2 1" ACCESSIBLE CLG SINGLE GANG 2/E8.03 3 <br /> _ . ! . . <br /> Os CEILWG TILE SPEAKER 1 gOX B <br /> vP +12.5"ABOVE BOARD VIDEO PROJECTOR 1 MUD RING 2 1-1/4" ACCESSIBLE CLG DOUBLE GANG &4/E8.0 - .�Q��. <br /> FPD +72" FLAT PANEL DISPLAIN 1 4-11/16" 1 1" ACCESSIBLE CLG DOUBLE GANG 4 <br /> � � �� <br /> � , ,- <br /> GENERAL NOTE: MOUNTING HEIGHTS INDICATED ON THE SCHEDULEREFER TO CENTER OF BACK BOX. �, <br /> NOTE 1: MOUNTING HEIGHT SHALL BE COORDINATED WITH OWNER FURNISHED, CONTRACTOR INSTALLED VIDEO PROJECTOR PRIOR TO INSTALLATION. 40�43 �� <br /> NOTE 2: CONDUITS FOR THE AV DEVICE SHALL TERMINATE IN THE ACCESSIBLE CEILING SPACE OF THE ROOM IN WHICH THE AV DEVICE RESIDES, UON. �� <br /> `�QN��. �� ������ <br /> NOTE 3: DEVICE REQUIRES NETWORK CONNECTION, PROVIDE CATEGORY 6 CABLfNG (CABLING BY 271100). TERMINATE ON IOT PATCH PANEL. <br /> NOTE 4: PROVIDE BLANK STAINLESS STEEL FACE PLATE WITH 2"C GROMMET HOLE. <br /> D � � � � � <br /> Everett High School <br /> Voc�tional �uilding <br /> Medical Pathways <br /> Project <br /> FOR <br /> Everett School <br /> D i stri ct �2 <br /> �� <br /> 2416 Colby Avenue <br /> Everett, WA 9�203 <br /> PERMIT RESl1�MITTAL <br /> 05/� 5/2019 <br /> This drawing is: <br /> C 1. Copyright 2019 Dykeman, Inc. � <br /> 2. The Architect's Instrument of Professional Service. <br /> 3. For use on this project only. Obtain ArchitecYs <br /> written permission for any other use or reproduction. <br /> _ � <br /> 2019-015 <br /> . <br /> B B <br /> . _ , , <br /> PRINCIPAL IN CHARGE:� <br /> PROJECT MANAGER: � <br /> PROJECT ARCHITECT: � <br /> JOB CAPTAIN: � <br /> . . <br /> � - . <br /> TELE�OM A�1 D � <br /> A LOW-VO LTAG E A <br /> ROUGH-IN <br /> �CHEDIJLES <br /> . - . <br /> 1 2 3 4 5 6 <br />
The URL can be used to link to this page