Laserfiche WebLink
1 2 3 4 5 6 <br /> ,� <br /> '� SHEET NOTES <br /> 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR <br /> EXACT LOCATION OF LIGHT FIXTURES. <br /> 2. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION OF <br /> WALL-MOUNTED LIGHT FIXTURES. <br /> _ Q ...,. , . .�__.. � * .. � � . � � k.�„ .., � <br /> 3. REFER TO LUMINAIRE AND SWITCH SCHEDULES ON SHEET E0.04 �' <br /> _ --- I , <br /> FOR ADDITIONAL INFORMATION. <br /> ����._ � _..: ...� <br /> 4. REFER TO SHEET E2.02A DRAWWGS FOR ADDITIONAL LIGHTING ` ` � �' � <br /> CONTROLS INFORMATION. � <br /> 5. WHERE EXPOSED TO STRUCTURE, COORDINATE CONDUIT � _ � _ _ � _ <br /> � ROUTING WITH ARCHITECT PRIOR TO ROUGH-IN. � <br /> • . . .. . .. � <br /> 6. FINAL OCCUPANCY SENSOR LAYOUT AND OCCUPANCY SENSOR <br /> E TYPES SHALL BE BASED ON MANUFACTURER SHOP DRAWINGS. E <br /> PROVIDE ADDITIONAL DEVICES AS REQUIRED FOR FULL <br /> ' COVERAGE. • � <br /> i <br /> � <br /> ! 7_ PHOTO SENSORS SHALL BE INSTALLED IN DAYLIGHTING ZONES <br /> � ACCORDING TO MANUFACTURER INSTALLATION INSTRUCTIONS. <br /> OFFSET LOCATIONS AS REQUIRED TO MEET MANUFACTURER H A R G I S <br /> REQUIREMENTS. <br /> � <br /> 8. LOCATE CONCEALED LIGHTING CONTROL COMPONENTS IN Hargis Engineers, Inc. <br /> NEAREST ACCESSIBLE CEILING SPACE. PROVIDE RED-LINE 1201 Third Avenue, Suite 600 <br /> COMPONENT LOCATION ON RECORD DRAWINGS. Seattle, WA 98101 <br /> 9. PROVIDE J-HOOKS ABOVE ACCESSIBLE CEILINGS FOR SUPPORT t� 206.448.3376 <br /> OF LOW VOLTAGE LIGHTING CONTROL CABLING. INSTALL J-HOOKS f� 206.448.4450 <br /> IN ACCORDANCE WITH SPECIFICATION SECTION 271100. PROVIDE w� hargis.biz <br /> CONDUIT FOR ROUTING LOW VOLTAGE LIGHTING CONTROL <br /> '' CABLING IN AREAS QF EXPOSED STRUCTURE, INACCESIBLE AREAS ' <br /> AND WITHIN PROXIMITY OF JUNTION BOXES PER SPECIFICATION <br /> -7 SECTION 271100 AND ELECTRICAL DETAILS. <br /> ; 10. IN MECHANICAL, ELECTRICAL,AND SIMILAR EQUIPMENT ROOMS, <br /> � COORDINATE LIGHT FIXTURE LOCATIONS AND MOUNTING WITH - . � . <br /> EQUIPMENT, PIPING AND DUCTWORK. ADJUST FIXTURE <br /> � LOCATIONS TO AVOID CONFLICTS AND EFFECTIVELY LIGHT THE <br /> � EQUIPMENT WORK SPACE. CONTRACTOR SHALL COORDINATE O� � <br /> CONDUIT INSTALLATIONS WITH DUCTWORK AND PIPING SYSTEMS 'q <br /> AND PROVIDE OFFSETS AS REQUIRED. PROVIDE RED-LINE �� <br /> FIXTURE LOCATIONS ON RECORD DRAWINGS. <br /> ' FLAG NOTES G� �� , <br /> �+UL � ���7 �� <br /> � CIRCUIT EMERGENCY LIGHTWG FIXTURES VIA <br /> ASSOCIATED 20A GENERATOR TRANSFER DEVICE(S)/UL <br /> p 924 RATED LIGHTING RELAY. LOCATE 20A GENERATOR - ' • � � • p <br /> TRANSFER DEVICE(S)ADJACENT TO RESPECTIVE <br /> LIGHTING PANEL. SEE DETAIL 1, SHEET E7.02 FOR <br /> i ADDITIONAL INFORMATION. <br /> i � COORDINATE LIGHT FIXTURE LOCATION AND MOUNTING Everett H ig h School <br /> � WITH EQUIPMENT, PIPING AND DUCTWORK. ADJUST • ■ • <br /> FIXTURE LOCATION TO AVOID CONFLICTS AND Vo cati o n a I B u�I d�n g <br /> EFFECTIVELY LIGHT THE SPACE. CONTRACTOR SHALL <br /> COORDINATE CONDUIT INSTALLATIONS WITH Med ica I Pathways <br /> i� , <br /> ,, DUCTWORK AND PIPING SYSTEMS AND PROVIDE <br /> �, OFFSETS AS REQUIRED. PROVIDE RED-LINE FIXTURE P ro j ect <br /> ' LOCATIONS ON RECORD DRAWINGS. <br /> FOR <br /> Everett School <br /> A ( B ) C D E F � D i stri ct #2 <br /> �� <br /> AT <br /> - � - - - - - � - - - - L - - - -�- - - � - - - - - - -�- - � - � 2416ColbyAvenue <br /> G3D G3D G3D E�/erett, WA 98203 <br /> — — — — . — 2 �-1- '4-1 _� _ _ F 1 D — — _ _ _ _ _ — 2 <br /> I i . � I B1-3 �1f3 _ D1#3 .;,.�._.. ; - , � .� ,;._. . -._ <br /> _.__� <br /> � <br /> o j _ oB�_2o B,_2 , , , PERMIT RESUBMITTAL <br /> �T O R�a�� � � G 4 D � G 4 D G 4 D G 4 D i � C C <br /> MECH. ����3 ;F1D D1D D1D O B1-2 p b1-2 p B1-2 61-2 p� ; 1 O`� `� <br /> G3D G3D G3 D B1_3 ---- p 8 1-2� B 1-2 b b b <br /> � � � p B1-1 p B1-1 p �B1-1 Op �, � c c `. � �� <br /> i ' This drawing is: <br /> � �--�--; D1 D D1 D � � <br /> C � '• ;Y �B1_2�._$1_2 2 � � ,— 1. Copyright 2019 Dykeman, Inc. C <br /> STaRA�� F1D c c ' G4D G4D G4D G4D � 2. The ArchitecYs Instrument of Professional Service. <br /> ���� ''�, B1-3 �' ' B1_2 B1_2 B�_2 B�_2 " 3. For use on this project only. Obtain ArchitecYs <br /> EXIS�iNG __: i D1 D D1 D O O O O + <br /> CLASSROOM 0 � B1-2 B1-2 b b b b ' ra� written permission for any other use or reproduction. <br /> G3D G3D G3D ; O O �� --____ - __ __.__ ___ <br /> � � _ i p B1-1 p 61-1 p B1-1 � ELEV. ASSROCJM �=�R�� <br /> � I DF i c c ` �� t--� I I <br /> I�_�. <br /> _ , <br /> - - <br /> 0� , .P2D P,2D 2 E204 I � ; � � • <br /> - <br /> � QB12� B1;-2 <br /> _ <br /> __ �1 ' �1 �__ -� `�. ' G4D G4D G4D G4D � �=;_� <br /> � ,��� <br /> �. <br /> (-n,P) 1 M � G2D o a1-2 p 61-2 p B1-2 61-2 O� ��� 2�� 9-015 <br /> I I _, ,__ I 0�� � � 0G1D I � a�-2 ' � I ( <br /> G1D G1D G1 G1D B1-5 __ _ _. -:. $2 ; :_ � ' • <br /> — — — — — �.�,...�.�,N.� - — <br /> — — — --B 1=� 'I�V=� �1- — 't€�1-=4—X2_ — ` �T — 3 <br /> B1-5 CC3R�1[�QR ; B1-5 1EV-4 _. G2D _L ,... .�__- _: --:,-- __.� `==" �2 � _,-� <br /> � --- B 1-5 � 61-4 <br /> I I �NAFT : � G1 p�� G1 p� ���� � ��G1 D � � �p a G4D G4D G4D G4D - <br /> _: � 1 I <br /> � 1D G1D 1EV-4 � O B1-4 O B1-4 O B1-4 B1-4 O, ' <br /> 1EV-4 1EV-4 B1 5 .._._._. F5D EV-4 F5D__..B1-5 B1-5 �-:__._„_. P2D P2D a a a a � -'°` <br /> _B1-5 '�_�`� 1 EV-4 1-5 ��a�E�=� 1 _ ___---- �B'(=��8')-4 -. <br /> _ _ 81-5 _ ._ I' _ <br /> _ _ ; <br /> - <br /> � ��B1-5 ��61-5 , � � � ' , <br /> ----------___-- --- I � � .. I ___ _ _._.� _ � F- _D'ID , D9b � '��� <br /> I I I S1� � F5D � � � F5D � 51� � -- �= O B��4 B�'4 G4D G4D G4D G4D j _� � � <br /> EXlSTING � 1EV-4 � � ��;, 1EV-�4 1EV 4 -� � I 1EV-4 � � C � � � B1-�4 2 O B1-4 O B1-4 B'I-4 O: -�*�-� <br /> S1D =� B1-5 B1-5 ��Y � S1D ��--� � D1D D1D b b b b , <br /> CLASSROOM A1-1 ` <br /> 1EV-4 � � � , � A1-1 1EV-4 �; p 61-4�_Q1=4 ' <br /> = A1-1 � i��N s �"C��dIEN�-,; � � A1-1 � c ' �L,��s��t��l � <br /> � <br /> _- .. ... ; <br /> �"a �., __ , <br /> � � � �:_��1C� '� � . D1D D1D �2�� <br /> � � � P1D ' ���� (TYP) � _ ' P1D ..,. � � � B1-40 B1-4 ___ . � I � <br /> G4D G4D G4D G4D ` <br /> qE 14 � F5D F5D � qE�4 � � ' O 61-4 2 O B1-4 O B1-4 B1-4 O' ' � <br /> � <br /> � � 1EV=4 1EV=4 � D1D D1p b b b b ' � <br /> i �V9t EIVT€2Y� B1-5 B1-5 , �� ��T�Y& r p B1-4� B1-4 Qp ;' � <br /> , <br /> i <br /> I �� I ' -�- � �� � c c , <br /> ����� , , �,���� <br /> � L--- — -----J __ . : . <br /> — -___. <br /> — — — _ .-_.��_. � __ _ <br /> — �— -- �— — — — — _.._ �._�d__._ ____._ ....�_ Y._ _� — � — — — — � 4 <br /> � <br /> B PROVIDE UNDER BID g <br /> — — — — LTERNATE#1_ — <br /> — — — — �- — 5 <br /> � <br /> � . <br /> � � � � � � � • <br /> PRINCIPAL IN CHARGE:� <br /> PROJECT MANAGER: � <br /> PROJECT ARCHITECT: � <br /> JOB CAPTAIN: � <br /> . <br /> , LEVEL 2 LIGHTING PLAN <br /> E2.o2 SCALE: 1/8" = 1'-0" <br /> � - . <br /> A LEVEL 2 LIGHTING A <br /> FLOOR PLAN <br /> . . <br /> 1 <br /> 1 2 3 4 5 6 <br />