i
<br /> N PROJECT NAME
<br /> �
<br /> W � p g 8 7 6 5 4 3 2 1 EVERETT WATERFRONT
<br /> w
<br /> _
<br /> �
<br /> W PLACE - HOTEL INDIGO
<br /> _ �
<br /> U
<br /> Q
<br /> � PROJECT ADDRESS
<br /> x
<br /> � � � � � � 265�-0° � I I � � 1002 MILLWRIGHT LOOP S
<br /> EVERETT, WA
<br /> � 6 CLIENT
<br /> � 8'-0" 15'-2" 13'-0" 13'-0" 13'-0" 13'-0" A4-0 ,_p,� 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 13'-0" 12'-11" 32'-11"
<br /> , , WATER PLACE HOTEL, LLC
<br /> 0 0 lo � - - o 0 0 0
<br /> 18230 E.VALLEY HIGHWAY#195
<br /> — KENT,WA 98032
<br /> T:425.251.160Q F:425.251.1900
<br /> I I ( I I I I I
<br /> '� ' � ; � I I �4Y -�
<br /> COLUMBIA HOSPITALITY
<br /> � � i — — — — — — — — - -- — — — W602 GWB02 �,
<br /> _ — — — — — — — — — A �� 2200 ALASKAN WAY,SUITE 200
<br /> �, cv I 7'-8�� 8,_5,�
<br /> ' � � � CO L�M B I A SEATTLE,WA 98121
<br /> � QQ-ADA T:206.239.1800, F:206.239.1801
<br /> QQ QQ QQ QQ QQ I QQ I K I N G K W G Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q K I N G 4 2 8 � HOSPITALITY..
<br /> � 411 � 412 413 41 415 416 � � � �
<br /> ' i 383 SF 359 SF 358 SF 359 F 358 SF I I 417 418 419 420 421 422 423 424 425 426 427 399 SF
<br /> 359 SF 3 5 2 S F 3 5 2 S F 3 5 8 S F 3 5 8 S F 3 5 8 F 3 5 9 S F 3 5 8 S F 3 5 9 S F 3 5 8 S F 3 5 9 S F 3 3 8 S F
<br /> "v i
<br /> , ,
<br /> N , I�I
<br /> GWB02 WB02 GW602 GW602 GWB02 I GWB02 I GWB02 GW602 GW602 GWB02 GWB02 GWB02 GW 02 GW602 GWB02 GW602 GW602
<br /> g'_5" g'_5" g'_5" g'_5" g'_5" g'_5" g'_5" g'-5" g'-5" g'-5" 8'-5" 8'-5" 8'-5" 8'- 8'-5" 8'-5" 8'-5��
<br /> I I � I � i i i
<br /> I GWB 2
<br /> ' STAIRS '� I 8 9
<br /> ', ST4.1 � I I
<br /> KING
<br /> I 149 SF f GWB02 429
<br /> GWB02 GI B02 GW602 GW602 GWB02 I GW602 I I GWB02 GWB02 I GWB02 GWB02 GWB02 GWB02 GWB 2 GWB02 GWB02 I GWB02 7'-$" I 306 SF I
<br /> � � � ' � � � �� � „ � � � � � � � �� � � � GWB02 GWB02
<br /> I�� I 7'-8" -8" 7 -8" 7'-8" 7 -8 7 -8 7 -8' 7'-8" 7'-8" 7'-8' 7'-8" 7'-8" 7'- 7'-8" 7'_8„ 7,_8"
<br /> I AP 7'-8" 8'_5"
<br /> ' � � � GWBO o_
<br /> W602 GWB02 � GWB02 GWB02 � GWB02 G - - —� GWB02 GW602 G B02 GW602 GWB02 � GW602 GW602 � GWB02 GWB02 � GW602 $ 5 GWB02 GWB02 �
<br /> 8'-9" 8'-5" o 0 8'-g�� 8�_5�� $�_9„ $�_5�, $�_9�� $,_5�� $�_9�� $,_5�� $�_9�� 8�_5�� $�_9" 8'-5" i 8'-9" 8'-9" !� 7'-8" 8'-5" ;
<br /> — —_lZl N� j — — — B
<br /> I — — — — — — — — — — — — — — — — — — — — — — �
<br /> � � i
<br /> � AP AP — � — � AP AP AP 2 AP AP AP 6, �,� 430
<br /> 306 SF
<br /> � � � -- � � GWB02
<br /> I GWB02 G 602 GWB02 GWB02 GWB02 GWB02 I GWB02 GW602 GWB02 GWB02 GWB02 GWB02 GWB 2 GWB02 GWB02 $ 9
<br /> � � � � � � � � � � � � � � � �� � � 7�-6
<br /> 7'-8" -8" 7'-8" 7'-8" 7'-8' 7'-8" 7'-8" 7'-8' 7 -8' 7'-8" 7'-8" 7'-8" 7'- 7'-8" �'-$" GWB02 ELEVLOBBY
<br /> I� 8'-5" 402
<br /> i I I I � I I I I I I 250 SF I I
<br /> - �' I �
<br /> N � � GW 802
<br /> KING-ADA
<br /> ;
<br /> cD ' � GWB02 WB02 GW602 GWB02 GWB02 GWB02 GW602 GW602 GWB02 GWB02 GW602 GWB02 GW 02 GW602 GWB02 431 �
<br /> ' 8'-5" 8'-5" 8'-5" 8'-5" I 8'-5" ( 8'-5" I ( 8'-5" 8'-5" I 8'-5" 8'-5° I 8'-5" 8'-5" 8'-5" 8'-5" 8'-5° ���3 r �` I
<br /> N . I I 401 SF I i
<br /> KINGSUITE KING KING KI G KING � KING I KING KING KING ING KING KING — �
<br /> � 446 445 444 4 3 442 441 440 439 438 36 433
<br /> KING KING KING � GW602 � --�—
<br /> 432 g�_5�� o_
<br /> 555 SF 309 SF 3�9 SF 30 SF 309 SF I 309 SF I 303 SF 303 SF 309 SF 437 3 9 SF 435 434 309 SF 309 SF GWBO i �
<br /> I I 309 SF 309 SF 309 SF $�_9�� � ____ i __
<br /> ' � � � I � � � � � i —
<br /> HOUSE KEEPING '
<br /> � — — — — 2 — — — — — �' —-+--
<br /> — — — — — — — — — — — — — — GWB02 403 STAIRS
<br /> ! 8'-5' 336SF
<br /> , GWB02 ST4.2
<br /> � I � � � � � � ( � 8'-5° �
<br /> 160 SF
<br /> 6
<br /> A4-030
<br /> 2 BP CORRECTION#1,ADDENDUM#2 12.11.2017
<br /> N0. DESCRIPTION: DATE:
<br /> REVISIONS
<br /> CONSULTANTS
<br /> � LEVEL 4 - RCP
<br /> 1 11 — ' ,f CIVIL ENGINEER
<br /> �� 1/8 1 -0 CPH Consultant
<br /> 11431 Wiliows Road NE,Suite 120
<br /> Redmond,WA 98052
<br /> T:425.285.2390, F:425.285.2389
<br /> LANDSCAPE ARCHITECT
<br /> Geyer Coburn Hutchins(GCH)
<br /> — 6101 22nd Ave.NW `
<br /> Seattle,WA 98107
<br /> T:206.285.4422, F:206.285.0644
<br /> STRUCTURAL ENGINEER
<br /> LEGEND Brienen Structural Engineers,PS
<br /> 1316 Central Avenue S,Suite 200
<br /> Kent,WA 98032
<br /> T:206.397.0000
<br /> ACOUSTICAL CEILING AND GRID � o o TRACK LIGHTING MECHANICALI ELECTRICAL ENGINEER
<br /> Tres West Engineers,Inc.
<br /> MAIN RUNNER SURFACE MOUNTED LIGHT 2702 South 42nd Street,Suite 301
<br /> � FIXTURE Tacoma,WA 98409
<br /> T:253.472.3300
<br /> � WALL SCONCE INTERIOR DESIGN
<br /> FLUORESCENT LIGHT FIXTURE Jensen Fey Architecture+Planning
<br /> ^ 7730 Leary Way NE
<br /> �� EXHAUST FAN Redmond,WA 98052
<br /> T:425.216.0318
<br /> � NIGHT LIGHT/24 HR. CIRCUIT FW FIRE WARDEN STATION
<br /> DRAWING STATUS
<br /> � EXISTING TO BE REMOVED 0 BUILDING PERMIT
<br /> SD SMOKE DETECTOR
<br /> r _ _ _ � UNDER CABINET FLUORESCENT ST STROBE
<br /> FixTURE Discrepancies must be reported to the Architect
<br /> # FIRE SPRINKLER before proceeding. Only figured dimensions are
<br /> �� FLUORESCENT STRIP FIXTURE to be used. Contractors must check all
<br /> OS SPEAKER dimensions on site. This drawing is protected
<br /> �—� FLUORESCENT PENDANT FIXTURE � MOTION DETECTOR by copyright. �
<br /> �" ALL DIMENSIONS ARE SHOWN IN IMPERIAL.
<br /> CEILING HEIGHT CHANGE AP ACCESS PANEL
<br /> X'-X" � SECURITY CAMERA
<br /> GWB-01 CEILING FINISH OT THERMOSTAT
<br /> DIMENSION OF CEILING ABOVE
<br /> X'-X" FINISH FLOOR � LIGHT SWITCH
<br /> FCP-01 SPECIAL FINISH-SEE SHEET A7.10 �� DIMMER SWITCH
<br /> WALL MOUNTED EXIT SIGN,SHOWS 0 PROJECTION SCREEN A R C H � T E C T U R E
<br /> �I QUANTITY OF FACE(S)AND DIRECTION
<br /> OF ARROW(S) � 600108th Ave.NE,Suite 108
<br /> RETURN AIR Bellevue,WA98004
<br /> CEILING MOUNTED EXIT SIGN,SHOWS T:425.559.7888, www.mza-us.com
<br /> �I QUANTITY OF FACE(S)AND DIRECTION � SUPPLY AIR
<br /> OF ARROW(S) STAMP NORTH ARROW
<br /> � RECESSED DOWNLIGHT � CIRCULAR DIFFUSER �
<br /> � � LINEAR DIFFUSER REGISTERED �
<br /> ADJUSTABLE DOWNLIGHT ARCHITECT
<br /> N � RECESSED WALL WASHER E REM�AIN S EXISTING TO .
<br /> s DENOTES EXISTING, Ming Zhang
<br /> o, R RELOCATED FIXTURE STATEOFWASHINGTON
<br /> i
<br /> J
<br /> Q
<br /> �
<br /> �
<br /> w DRAWING TITLE
<br /> U
<br /> W�
<br /> � LEVEL 4 RCP
<br /> Q
<br /> J
<br /> �
<br /> �
<br /> Z
<br /> �
<br /> �
<br /> lL
<br /> �
<br /> W
<br /> �
<br /> Q DRAWN CHECKED
<br /> �
<br /> � YM CBD
<br /> �
<br /> w
<br /> w SCALE @ ARCH E1 DATE
<br /> w 1/8" = 1'-0" 10/02/2017
<br /> �
<br /> �
<br /> � GRAPHIC SCALE
<br /> ; 0 4 8 16 24
<br /> �
<br /> �� SCALE W FEET
<br /> U�
<br /> O�
<br /> �� PROJECT N0.
<br /> N N
<br /> o� 16-058
<br /> ��
<br /> ��
<br /> °�,'� DRAWING N0. REVISION N0.
<br /> �rn
<br /> U�
<br /> �� �
<br /> z�
<br /> w~
<br /> �O
<br /> �a
<br /> I
<br />
|