Laserfiche WebLink
� <br /> i i i i i i i i <br /> N <br /> 'n PROJECT NAME .. <br /> �- <br /> � <br /> � - EVE�ETT �IATERF��NT <br /> �n <br /> �� CODE NOTES - SIGNAGE 7Y�'lCAL MOUNTING HEIC�HTS (ANSI 117.1) L C � T L � I � <br /> U <br /> Q <br /> ZV <br /> " TOILET PAPER ELECTRIC PROJECTADDRESS <br /> m IBC SECTION 1111 -SIGNAGE TOILET PAPER DISPENSER MOP SINK UTILITY WATER COOLER TOWEL BAR(TYP.) SOAP <br /> CENTERLINE OF DOOR DISPENSER BASIN SHELF <br /> CENTERLINE AND SIGN (ACCESSIBLE) 002 R GHT LOOP S <br /> DISPENSER <br /> OF SIGN � 1111.1 SIGNS VERTICAL GRAB URINAL FLUSH MOP AND ELECTRIC ROBE HooK EVERETT, IIVA <br /> REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF 1'-0" 3'-6" MI . gqR VALVE BROOM WATER COOLER PERSONAL <br /> ACCESSIBILITY AT THE FOLLOWING LOCATIONS. HOLDER ' EMERGENCY <br /> 3'-4° TILE WAINSCOT PULL SWITCH CLIENT <br /> � 1.ACCESSIBLE PARKING SPACES REQUIRED BY SECTION 1106.1. 3 -0 MIN. SEE INT. ELEVS o�=-° o°� � <br /> 0 o z GRAB � 1�-o�� Mitv. w J I J WATER PLACE HOTEL, LLC � <br /> ,' 2.ACCES5IBLE PARKING SPACES REQUIRED BY SECTION 1106.2. � BAR � _ � � � � w Q <br /> n � /� 6'-0" � cn � T � w � cc��-�, � > 18230 E.VALLEY HIGHWAY#195 <br /> I I II� A.F.F. 3.ACCESSIBLE PASSENGER LOADING ZONES. _' o � � W o m � 00 0 � "- KENT,WA 98032 <br /> I _ - � � � - _ <br /> T N Q � p m � c�i `,, m � T:425.251.1600, F:425.251.1900 <br /> ' 4.ACCESSIBLE ROOMS WHERE MULTIPLE SINGLE-USER TOILET OR BATHING ROOMS ARE � � � � m 1 � Q I o � � m o U `f' � �.�.. � z �r_ <br /> , _ � , - ' o F' O � � � Q ih w r� � <br /> ( CLUSTERED AT A SINGLE LOCATION. N �^ � N � M _ _� o � � _ � COLUM�IA HOSPITALITY <br /> � � �,, � �C° -� ti o ' °' � FINISH FLOOR LWE � <br /> 5.ACCESSIBLE ENTRANCES WHERE NOT ALL ENTRACES ARE ACCESSIBLE. 2200 ALASKAN WAY,SUITE 200 <br /> MEN!WOMEN OR UNISEX AS REQUIRED PER PLAN - 1'-6" x � ° `� - SEATTLE,WA 98121 <br /> °' z �--.F- Q 6"INTEGRATED COVED B�SE `�' { � �o�u N���A <br /> SEE PLAN FOR SIGNAGE LOCATIONS. PER ADA SECT.407.2.2.2 7. FAMILY OR ASSISTED-USE TOILET AND BA7HING ROOMS. � � � PER IBC 1210.1 SEE FINISH i� ' CLOSET ROD HOSPITALITY�M T:206.239.1800, F:206.239.1801 <br /> T $ ``' � SCHEDULE-TYP AT � AND SHELF <br /> 10. EXTERIOR AREAS FOR ASSISTED RESCUE IN ACCORDANCE WITH SECTION 1009.9. -� TOILET SEAT PAPER TOWEL RESTROOMS BABY CHANGWG WALL SWITCH FIRE ALARM VISUAL SIGNAL LINEN CLOSET <br /> RESTROOM SIGNAGE COVER DISPENSER DISPENSER STATION- PULL BOX FlRE STROBE SHELVING .� <br /> (RECESSED) RECESSED EXTINGUISHER <br /> NOTE: IDENTIFICATION SYMBOLS ICC ANSI 117.1 COMBINATION PAPER PAPER TOWEL SANITARY NAPKIN ELEVATOR THERMOSTAT c9 c9 <br /> PER ADA SECT.4.30 SIGNAGE TOWEL DISPENSER W/ DISPENSER W/ DISPENSER CALL BUTTON CABINET J J ADA CLOSET <br /> U U ROD AND SHELF <br /> 703.1.3 PICTOGRAMS.WHERE PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT WASTE RECEPTACLE WASTE RECEPTAC�E � <br /> SANITARY NAPKIN � � � � � <br /> INTERIOR ROOMS AND SPACES,THE PICTOGRAMS SHALL COMPLY WITH SECTION 703.5 AND SHALL ' � <br /> RECEPTACLE <br /> / HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD AND COMPLYWG n m m � � J . <br /> � w w � <br /> , WITH SECTIONS 703.2 AND 703.3. �, � W <br /> � � � � � � , � O O � � _ , <br /> � �( ] � d � � � � <br /> 703.5 PICTOGRAMS. � � `J w o z z O O p � <br /> jO% // i� ,� _ - - - - - - - XQ - X � � O O o' <br /> 703.5.1 GENERAL. PICTOGRAMS SHALL COMPLY WITH SECTION 703.5 0� o 0 0 0 0 0 0 � o w � � F-- �-- � <br /> • , � � � � � � � _ , <br /> INTERNATIONAL SYMBOL OF ACCESSIBILITY PER o `'' � � `� � � � � � o � O � ' � ��`" a <br /> 703.5.2 PICTOGRAM FIELD. PICTOGRAMS SHALL HAVE A 6 WCHES FIELD MW. IN HEIGHT. � � � �. �- � � � ¢ Q <br /> ICC ANSI 117.1-2009 FIG.703.6.3.1 - O O O � � �- FINISH FLOOR LINE ' <br /> _ CHARACTERS OR BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. - z , , <br /> W c� �n �n u-� .� <br /> 703.5.3 FINISH AND CONTRAST. PICTOGRAMS AND THEIR FIELDS SHALL HAVE A NON o � � � <br /> GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THIER FIELDS,WITH EITHER A OUTLET Q O O � <br /> _ <br /> LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. � <br /> - � <br /> 703.6 SYMBOLS OF ACCESSIBILiTY <br /> CODE N�TES - GLASS TYPICAL CLEARANCE� t' <br /> 703.6.1 GENERAL. SYMBOLS OF ACCESSIBILITY SHALL COMPLY WITH SECTION 703.6 <br /> 703.6.2 FINISH AND CONTRAST.SYMBOLS OF ACCESSIBILITYAND TNEIR BACKGROUNDS SHALL I 4'-0" <br /> NAVE A NON GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR SECTION 2406:SAFETY GLAZING INSULATE HOT WATER <br /> FIELDS,WITH EITHER A LIGHT SYMBSOL ON A DARK FIELD OR A DARK SYMBOL ON A -- <br /> LIGHT FIELD. 2406.1: HUMAN IMPACT LOADS WDIVIDUAL GLAZED AREAS, INCLUDING GLASS MIRRORS, IN PIPES AND DRAIN TO _ _ <br /> ; ��i <br /> HAZARDOUS LOCATIONS AS DEFINED IN SECTION 2406.4 PREVENT CONTACT C� <br /> z <br /> SHALL COMPLY WITH SECTIONS 2406.1.1 THROUGH 2406.1.4. LINE OF REQUIRED � � <br /> CLEARANCE --� c=j i\ <br /> 2406.3 HAZARDOUS LOCATIONS.THE FOLLOWING SHALL BF CONSIDERED SPECIFIC HAZARDOUS MIRROR � � � _ <br /> LOCATIONS �� � � � - <br /> REQUIRING SAFETY GLAZING MATERIALS: � <br /> p N <br /> -� p � � � 2 <br /> CODE NOTES - GRA� BARS CO�E NOTES -TOILET AND �ATHR04M 1.GLAZING IN SWINGING DOORS EXCEPT JALOUSIES(SEE SECTION 2406.3.1) �\ � � � � <br /> 2.GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING - G � � � <br /> 306.2 NA I <br /> 39 -41'MIN. AND BIFOLD CLOSET DOOR ASSEMBLIES i �- <br /> � 18"VERTICAL � � <br /> 12"MAX <br /> GRAB BAR ICC A917.1.603 TOILET AND BATHWG ROOMS: 3.GLAZING IN STORM DOORS � � � - � <br /> I � 42"MIN. � z z � _ <br /> I 1. 603.2.1 TURNWG SPACE: A TURNING SPACE COMPLYING WITN 304 SHALL BE 4.GLAZING IN UNFRAMED SWINGING DOORS Z � � o � _"' <br /> 24"MIN ``' � <br /> , , PROVIDED WITHIN THE ROOM _____.------ �- �? N N <br /> 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS,WHIRL-POOLS, SAUNAS, STEAM ROOMS, 6, N �� <br /> a' B' 2. 603.2.3 DOOR SWING: DOORS SHALL NOT SWING INTO THE CLEAR FLOOR BATHTUBS AND SHOWERS.GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE <br /> I i"i �. iri SPACE OR CLEARANCE FOR ANY FIXTURE. COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF HTE GLAZWG IS LESS THAN 60 INCHES <br /> � W C - ai = � (1524MM)ABOVE A STANDING SURFACE KNEE CLEARANCE 8"MIN. 6" AX TOE CLEARANCE � <br /> 1 1I2° � � M � � U EXCEPTIONS: _ <br /> ' M� - a � v m � 1. DOORS TO A TOILET AND BATHING ROOM 6.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE 20"MIN. DEPTH � <br /> °' � NEARESTEXPOSED EDGE OF THE GLAZWG IS WITHIN 24-WCH(610MM)ARC OF EITHER VERTICAL �j � <br /> 1-1/4"-2"MAX PE� -� � - w FOR A SINGLE OCCUPANT,ACCESSED ONLY 7HROUGH A - <br /> F� v a EDGE OF 7HE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF HTE - N0. DESCRIPTION: DATE: <br /> ICC 609.2.1 GRAB BAR SECTION � U PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC � <br /> �- - -- USE SNALL BE PERMITTED TO SWING INTO THE CLEAR GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKWG SURFACE N a REVISIONS <br /> FLOOR SPACE, PROVIDED THE SWING OF THE DOOR CAN 2'-0"MIN. � <br /> 3'-0"MW GRAB BARS PER ICC 604.5 BE REVERSED TO MEET SECTION 603.2.3 CONSULTANTS <br /> CLEAR <br /> �� � M N. � M N. � 2.WHERE THE ROOM IS FOR INDIVIDUAL USE AND A FLOOR � ' 4 � I' CIVIL ENGINEER <br /> J CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3 IS SPACE CPH Consultant <br /> i�i � PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE z - -_� � .W <br /> FLUSH HANDLE � � o PROVIDE HEAVY DUTY BACKING DOOR SWING. � 10' 2'-6" <br /> _ 43 i ows Roa NE,Suite 120 <br /> ON WIDE SI�E � �, � AT ALL GRAB BARS o i � Redmond,WA 98052 <br /> - OF STALL OR r�I � c� cU SEE BACKING�ETAIL 3. 603.3 MIRRORS: MIRRORS LOCATED A80VE LAVATORIES,SINKS OR co T:425.285.2390, F:425.285.2389 <br /> ``' c� COUNTERS SHALL BE MOUNTED WITH THE BOTTOM EDGE 40 INCHES MAX. LANDSCAPE ARCHITFCT <br /> RooM _ � THRESf�OLDS Geyer Coburn Hutchins(GCH) <br /> - ABOVE THE FLOOR. MIRRORS NOT LOCATED ABOVE LAVATORIES,SINKS OR 1'-7"M . / S�ALE: FULL 2 6101 22nd Ave.NW <br /> _ �-� , COUNTERS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE �d�E NOTES � DOORS Seattle,WA 98107 <br /> TOILET ��� 16"-18"-ACCESSIBLE PER ICC 604.2 REFLECTING SURFACE 35 INCHES MAX.ABOVE THE FLOOR 43"MIN. w T:206.285.4422, F:206.285.0644 <br /> 17"-19"-AMBULATORY PER ICC 604.2 4. 603.4 COAT HOOKS AND SHELVES: COAT HOOKS SHALL BE LOCATED WITHW z STRUCTURAL ENGINEER <br /> ONE OF THE REACH RABGES SPECIFIED IN SECTION 308.SHELVES SHALL BE � �rienen Structural Engineers,PS <br /> 40 INCHES MIN.AND 48 WCHES MAX.ABOVE THE FLOOR. LC.C.404 DOORS AND DOORWAYS: $INK C�R VANITY � = 1316 Central Avenue S,Suite Z00 <br /> SCALE: 1/2" � 1'�0" � � � Kent,WA 98032 <br /> 404.1 GENERAL. ' T:206.397.0000 <br /> DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH �w � � MECHANICAU ELECTRICAL ENGWEER <br /> 5. 604.1 GENERAL: ACCESSIBLE WATER CLOSETS AND TOILET COMPARTMENTS SECTION 404. � Tres West Engineers,Inc. <br /> �. 604.5.1 FIXED SIDE WALL GRAB BARS: FIXED SIDEWALL GRAB BARS SHALL COMPLY WITH SECTION 604.COMPARTMENTS CONTAINING MORE a � � 2702 South 42nd Street,Suite 301 �, <br /> SHALL BE 42 INCHES MIN. IN LENGTH, LOCATED 12 INCHES MAX. FROM THAN ONE PLUMBING FIXTURE SHALL COMPLY WITH SECTION 603. _ I I Tacoma,WA 98409 <br /> THE REAR WALL AND EXTENDING 54 WCHES MIN. FROM THE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS AND MANUAL GATES, INCLUDING � `O T:253.472.3300 <br /> TICKET GATES,SHALL COMPLY WITH THE REQUIREMcNTS OF SECTION 404.2 EQUIPMENT PERMITTED IN `Y' � INTERIOR DESIGN <br /> IN ADDITION,A VERTICAL GRAB BAR 18 WCHES MIN. IN LENGTH SHALL BE 604.8.AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH � I I <br /> MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39 INCHES SECTION 604.9 SHADED AREA � Jensen Fey Archi#ecture+Planning <br /> 404.2.1 DOUBLE-LEAF DOORS AND GATES.THE ACTIVE LEAVES OF DOORWAYS WITH TWO 1'- "MIN. <br /> ABD 41 INCHES ABOVE THE FLOOR,AND WITH THE CENTER LINE OF THE � � 7730 Leary Way NE <br /> BAR LOCATED BETWEEN 39 WCHES AND 41 INCHES FROM THE REAR WALL 6. 604.2 LOCATION: THE WATER CLOSET SHALL BE LOCATED WITH A WALL OR LEAVES SHALL COMPLY WITH SECTIONS 404.2.2 AND 404.2.3 w <br /> PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER , _ _ � o Redmond,N!A 98052 <br /> c� � T:425.216.0318 <br /> CLOSET SHALL BE 16 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM THE <br /> SIDE WALL OR PARTITION.WATER CLOSETS LOCATED IN AMBULATORY 404.2.2 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES MIN. � � - �8��M�N \ � � <br /> CLEAR OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED 1'-5"TO 1'-7" f �- U p DRAWING STATUS <br /> ACCESSIBLE COMPARTMENTS SPECIFIED IN SECTION 604.9 SHALL HAVE THE � I z � <br /> 2. 604.5.2 REAR WALL GRAB BARS: THE REAR WALL GRAB BAR SHALL BE 36° BETWEEN THE FACE OF THE DOORAND STOP,WITH THE DOOR OPEN 90 DEGREES. �U�L�IN� PE���� <br /> CENTERLINE OF THE WATER CLOSET 17 INCHES MIN. TO 19 INCHES MAX. � � � <br /> MIN. IN LENGTH,AND EXTEND FROM THE CENTERLINE OF THE WATER OPENINGS, DOORS AND DOORWAYS WITHOUT DOORS MORE THAN 24 INCHES IN DEPTH SHALL � - <br /> FROM THE SIDE WALL OR PARTITION q <br /> CLOSET 12 INCHES MIN. ON THE SIDE CLOSEST TO THE WALL,AND 24 PROVIDE A CLEAR OPENING WIDTH OF 36 WCHES MIN.THERE SHALL BE NO PROJECTIONS INTC �� � O <br /> INCHES MIN.ON THE TRANSFER SIDE THE CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FLOOR. PROJECTIONS WTO = �, � I _ _ _ � o <br /> 7, 604.3 CLEARANCE: THE CLEAR OPENWG WIDTH BETWEEN 34 INGHES AND 80 INCHES ABOVE THE FLOOR SHALL � <br /> 604.3.1 CLEARANCE WIDTH. A CLEARANCE AROUND A WATER CLOSET 60 INCHES NOT EXCEED 4 INCHES. - DISCC@pa11Cl@S C11USt b2 i'2p01�2CI t0 tfl@ AI'Cf1lteCt �" <br /> % ° � before proceeding. Only figured dimensions are <br /> 3 609.1 GENERAL: GRAB BARS IN ACCESSIBLE TOILET OR BATHWG MINIMUM IN WIDTH, MEASURED PERPENDICULAR FROM THE SIDEWALL. EX�EPTIONS. � 0 to be used. Contractors must check all <br /> FACILITIES SHALL COMPLY WITH SECTION 609. z <br /> 1. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MIN.ABOVE THE z � o -� dimensions on site. This drawing is protected <br /> 4. 609.2.1 CIRCULAR CROSS SECTION: GRAB BARS WITH A CIRCULAR 8. 604.3.2 CLEARANCE DEPTH. CLEARANCE AROUND THE WATER CLOSET SHALL BE FLOOR. � - � �,, <br /> by copyright. <br /> CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1-1/4°MIN.AND 56 INCHES MINIMUM IN DEPTH, MEASURED PERPENDICULAR FROM THE REAR WALL. 2:IN ALTERATIONS.A PROJECTION OF 5/8 INCH MAX. INTO THE REQUIRED CLEAR OPENING � `� 5'-0"MIN. <br /> 2 INCHES MAX. WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. ALL DIMENSIONS ARE SHOWN IN IMPERIAL. <br /> 5. 609.2.2 NON-CIRCULAR CROSS SECTION: GRAB BARS WITH A NON 9. 604.3.3 OVERLAP: THE REQUIRED CLEARANCE AROUND THE WATER CLOSET KNEE CLEARANCE 8"MIN. 6"�IAX TOE CLEARANCE <br /> SHALL BE PERM(TTED TO OVERLAP THE WATER CLOSET,ASSOCIATED GRAB 10"MAX. � <br /> CIRCULAR CROSS SECTION SHALL HAVE A CROSS SECTION DIMENSION � 2'-6° � � <br /> BARS, PAPER DISPENSERS,SANITARY NAPKIN RECEPTACLES, COAT HOOKS, 404.2.3.1 FLOOR SURFACE.FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL I <br /> OF 2 INCHES MAX.AND A PERIMETER DIMENSION OF 4 INCHES MIN.AND SHELVES,ACCESSIBLE ROUTES,CLEAft FLOOR SPACE AT OTHER FIXTURES HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY WITH SEGTION 302 <br /> 4.81NCHES MAX. <br /> AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL 4'-0"MIN. <br /> 6. 609.2.3 SPACWG THE SPACE BETWEEN THE WALL AND THE GRAB BAR BE WITHIN THE REQUIRED WATER CLOSET CLEARANCES. 404.2.4 THRESHOLDS AT DOORWAYS: IF PROVIDED.THRESHOLD AT DOORWAYS SHALL BE 1/2 <br /> SHALL BE 1-1l2".THE SPACE BETWEEN THE GRAB BAR AND PROJECTING INCH MAX. IN HEIGHT. RAISED THRESHOLDS AND CHANGES W LEVEL AT DOORWAYS SHALL 1'-5"TO 1'-7" 2'-8"MIN. � - ' ,, <br /> OBJECTS BELOW AND AT THE ENDS OF THE GRAB BAR SHALL BE 1-1/2° �� 604.4 HEIGHT: THE HEIGHT OF WATER CLOSET SEATS SHALL BE 17 INCHES COMPLY WITH SECTIONS 302 AND 303. <br /> MIN.THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS MIN.AND 19 INCHES MAX.ABOVE 7HE FLOOR, MEASURED TO THE TOP OF HTE � U 4'-0"MIN. <br /> ABOVE THE GRAB BAR SHALL BE 12"MIN. SEAT.SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. <br /> CLEAR A R C H I T E C T U R E <br /> 305.7(a) <br /> FLOOR <br /> - 7. 609.4 POSITION OF GRAB BARS: GRAB BARS SHALL BE INSTALLED IN A w 600108th Ave.NE,Suite 108 <br /> HORIZONTAL POSITION,33 WCHES MIN.AND 36 INCHES MAX.ABOVE THE SPACE _ � Bellevue,WA 98004 <br /> FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE.AT WATER \�O � � � T:425.559.7888, 4vww.mza-us.com <br /> - CLOSETS PRIMARILY FOR CHILDRENS USE COMPLYWG WITH SECTION 604.11, �ODE NOTES - DOOR SWINGS � o i..� <br /> - GftAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18"MIN.AND 27" cv � � U STAMP NORTH ARROW <br /> MAX ABOVE THE FLOOR MEASURED TO TNE TOP OF THE GRIPPING SURFACE � z �s <br /> TABLE 404.2.3.1 MANEWERING AT MANUAL SWINGWG DOORS N o REGISTERED <br /> � 8. 609.5 SURFACE HAZARDS: GRAB BARS,AND ANY WALL OR OTHER SURFACES TYPE OF USE MINIMUM MANEUVERING CLEARANCES 2'-0"MAX. 3'-0"MIN. � ARCHITECT , <br /> � ADJACENT TO GRAB BARS,SHALL BE FREE OF SHARP OR ABRASIVE APPROACH DOOR PARALLEL TO DOORWAY � ' • � <br /> � ELEMENTS. EDGES SHALL BE ROUNDED DIRECTION SIDE PERPENDICULAR TO DOORWAY (gEYOND LATCH UNLESS NOTED) <br /> �0 9. 609.6 FITTINGS: GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS FROM FRONT PULL 60 WCHES 18 INCHES Ming Zhang <br /> DRINKING F�UNTAlN REACH RANGES CLEARANCES STATEOFWASHINGTON <br /> � FROM FRONT PUSH 48 WCHES 0 WCHES (3) S�AL�: '�/2�� = 1�-��� � SCALE: 1/�'� = 7�-�'� �' $C/��.�: 1/2�� = ��-��� � <br /> � FROM HWGE SIDE PULL 60 INCHES 36 INCHES <br /> z <br /> �t i FROM HWGE SIDE PULL 54 INCHES 42 INCHES DRAWING TITLE <br /> ��� CLEAR WIDTH A � <br /> � FROM HWGE SIDE PUSH 42 INCHES <br /> 2 FROM LATCH SIDE PULL 48 INCHES (2) 24 WCHES 4 <br /> A�CESSI�LE R��� �YPE <br /> O �„M�. ��TE� <br /> z FROM LATCH SIDE PUSH 42 INCHES (3) 24 INCHES <br /> Lobby ,� <br /> O <br /> � <br /> �� <br /> ,� NOTES: � _� .J <br /> r- 1.ADD 6 INCHES IF CLOSER AND LATCH PROVIDED <br /> � 2.ADD 6 INCHES IF CLOSER PROVIDED �,, DRAWN CHECKED <br /> �-- 3.ADD 12 WCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED Z N YM CBD <br /> � 4. BEYOND HINGE SIDE � Q <br /> rr �� _ �� <br /> J � <br /> ] � � SCALE @ ARCH E1 DATE <br /> �� , 36���niN. � � � '� m 10/02/2017 <br /> �, _ <br /> � 32"MIN. � <br /> r 32"MIN. � 32"MIN. � ,�_�_ _ - GRAPHIC SCALE <br /> r ��� � � � � <br /> �2 0 � � <br /> U�- p� <br /> p� A CAN BE ANY AMOUNT IF'B'IS 2'-2' <br /> � >24' MAX. ' ' � <br /> •oN (B)SLIDING DOOR (C)FOLDWG DOOR OR LESS '� <br /> }� PROJECT N0. <br /> no 'A'NOT TO EXCEED 1Q0 IF'B'IS MORE �6-��$ <br /> j� (D)DOORWAYS THAN 2'-2" DRAWING N0. REVISION N0. <br /> nN WITHOUT DOORS PROTRUDING OBJECTS <br /> �j� (A)HINGED DOOR �C�L�: 1/4�� _ ��-Q�� 6 . <br /> J�J <br /> Z� <br /> � <br /> ��r <br /> �� <br /> i�n <br /> I <br />