WIND LOAD CRITERIA-COMPONENTS&CLADDING COMPONENTS&CLADDING DESCRIPTION <br /> WIND LOAD CALCULATIONS ARE IN ACCORDANCE WITH MOST CONSERVATIVE C&C PRESSURE WITH MINIMUM <br /> THE 2015 IBC AND ASCE 7-10 AS ADOPTED BY THE CITY OF EFFECTIVE WIND AREA< 10 S.F. <br /> EVERETT. ANALYSIS PROCEDURE IS CHAPTER 30, PART 1 <br /> LOW RISE BUILDINGS W/H<60FT. <br /> PRESSURE COEFFICIENTS <br /> ENCLOSURE CLASSIFICATION ENCLOSED <br /> INTERNAL PRESSURE COEFF. GCpi= 0.18 +/- <br /> VELOCITY PRESSURES ROOF TYPE [30.4-2C]GABLE,27°<e<45° <br /> RISK CATEGORY II ROOF OVERHANG? OVERHANG PRESENT <br /> BASIC WIND SPEED V= 110 MPH <br /> DIRECTIONALITY FACTOR Kd= 0.85 (1)ROOF FIELD +GCp= 0.90 <br /> TOPOGRAPHIC FACTOR Kzt= 1.00 (1)ROOF FIELD -GCp= -1.00 <br /> EXPOSURE CATEGORY C (1)ROOF FIELD,OVERHANG GCp= N.A. <br /> (2)ROOF EDGE +GCp= 0.90 <br /> (2)ROOF EDGE -GCp= -1.20 <br /> HEIGHT,Z(FT) PRESSURE VELOCITY PRESSURE, (2)ROOF EDGE,OVERHANG GCp= -2.00 <br /> COEFFICIENT, Kz Qz(PSF) (3)ROOF CORNER +GCp= 0.90 <br /> 0 0.85 22.35 (3)ROOF CORNER -GCp= -1.20 <br /> 15 0.85 22.35 (3)ROOF CORNER, OVERHANG GCp= -2.00 <br /> 20 0.90 23.75 (4)WALL FIELD +GCp= 1.00 <br /> 25 0.95 24.89 (4)WALL FIELD -GCp= -1.10 <br /> 30 0.98 25.86 (5)WALL EDGE +GCp= 1.00 <br /> 40 1.04 27.48 (5)WALL EDGE -GCp= -1.40 <br /> 50 1.09 28.80 <br /> 60 1.14 29.93 DESIGN PRESSURES <br /> *12.5 0.85 22.35 ROOF SLOPE 9= 18.43 DEG <br /> **15 0.85 22.35 BUILDING WIDTH W= 28 FT <br /> *MEAN ROOF HEIGHT, h (FT) WIDTH OF PRESS.COEFF.ZONE a= 3 FT <br /> **EVE HEIGHT,he(FT) <br /> MAX.POSITIVE MAX.NEGATIVE <br /> BUILDING SURFACE DESIGN DESIGN <br /> PRESSURES,p PRESSURES,p <br /> (PSF) (PSF) <br /> (1)ROOF FIELD 24.1 -26.4 <br /> (1)ROOF FIELD,OVERHANG N.A. N.A. <br /> (2)ROOF EDGE 24.1 -30.8 <br /> (2)ROOF EDGE,OVERHANG -48.7 <br /> (3)ROOF CORNER 24.1 -30.8 <br /> (3)ROOF CORNER,OVERHANG -48.7 <br /> (4)WALL FIELD 26.4 -28.6 <br /> (5)WALL EDGE 26.4 -35.3 <br /> project 2603 E GRAND AVE by BJW sheet no. <br /> AieCOFFIS1Af1 location EVERETT,WA date 5/16/2018 <br /> NGINEERS client check job no. <br /> topic COMPONENTS&CLADDING date 180979 <br />
The URL can be used to link to this page
Your browser does not support the video tag.