Laserfiche WebLink
MEMBER REPL Roof Level, Bathroom Header PASSED <br /> 1 piece(s)4 x 6 Hem-Fir No.2 <br /> Overall Length: 5' 9" <br /> 0 0 <br /> 5'6" <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Roof <br /> Member Reaction(lbs) 918 @ 0 2126(1.50") Passed(43%) -- 1.0 D+1.0 5(All Spans) Member Type:Drop Beam <br /> Shear(lbs) 732 @ 7" 2214 Passed(33%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 1320©2'10 1/2" 1869 Passed(71%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.083 @ 2'10 1/2" 0.192 Passed(L/833) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.125 @ 2'10 1/2" 0.287 Passed(L/554) -- 1.0 D+1.0 S(All Spans) Member Pitch:0/12 <br /> •Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 5'9"o/c unless detailed otherwise. <br /> •Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 5'9"o/c unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> Bearing Loads to Supports(lbs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> 1-Stud wall-HF 1.50" 1.50" 1.50" 307 611 918 Blocking <br /> 2-Stud wall-HF 1.50" 1.50" 1.50" 307 611 918 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Tributary Dead Snow <br /> Loads Location(Side) Width (0.90) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 5'9" N/A 4.9 <br /> 1-Uniform(PSF) 0 to 5'9"(Front) 8'6" 12.0 25.0 Roof <br /> Weyerhaeuser Notes SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Use of this software is not Intended to circumvent the need for a design <br /> professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is <br /> compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards,Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES <br /> under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser <br /> product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support Information have been provided by Forte Software Operator <br /> Forte Software Operator ,lob Notes 5/16/2018 8:13:58 PM <br /> Brian Walkenhauer Forte v5.3,Design Engine:V7.0.0.5 <br /> Coffman Engineers Grand Ave Gravity Design.4te <br /> (206)623-0616 <br /> walkenhauer@coffman.com Page 5 of 9 <br />