Laserfiche WebLink
• <br /> • <br /> j F O R T E MEMBER REPO Floor Level,Floor:Joist PASSED <br /> 1 piece(s)2 x 8 Hem-Fir No.2@ 24"OC <br /> Overall Length: 6' 3" <br /> 0 0 <br /> El <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 325 @ 1/2" 911(1.50") Passed(36%) -- 1.0 D+1.0 L(All Spans) Member Type:Joist <br /> Shear(lbs) 249 @ 8 3/4" 1088 Passed(23%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 494 @ 3'1 1/2" 1284 Passed(38%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.042 @ 3'1 1/2" 0.154 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.055 @ 3'1 1/2" 0.308 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) <br /> T3-Pro'"Rating N/A N/A -- -- -- <br /> • Deflection criteria:LL(L/480)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 6'3"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 6'3"o/c unless detailed otherwise. <br /> •A 15%increase in the moment capacity has been added to account for repetitive member usage. <br /> •Applicable calculations are based on NDS. <br /> • No composite action between deck and joist was considered in analysis. <br /> Bearing Loads to Supports(lbs) <br /> Supports Total Available Required Dead Floor Total Accessories <br /> Live <br /> 1-Beam-HF 1.50" 1.50" 1.50" 75 250 325 Blocking <br /> 2-Beam-HF 1.50" 1.50" 1.50" 75 250 325 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Floor Live <br /> Loads Location(Side) Spacing (0.90) (1.00) Comments <br /> 1-Uniform(PSF) 0 to 6'3" 24" 12.0 40.0 Residential-Living <br /> Areas (O <br /> Weyerhaeuser Notes Y SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Use of this software is not intended to circumvent the need for a design <br /> professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is <br /> compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES <br /> under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser <br /> product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 5/16/2018 8:13:58 PM <br /> Brian Walkenhauer Forte v5.3,Design Engine:V7.0.0.5 <br /> Coffman Engineers Grand Ave Gravity Design.4te <br /> (206)623-0616 <br /> walkenhauer@coffman.corn <br /> Page 8 of 9 <br />