My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6133 LAKE CHAPLAIN RD 2020-03-09
>
Address Records
>
LAKE CHAPLAIN RD
>
6133
>
6133 LAKE CHAPLAIN RD 2020-03-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:07:49 AM
Creation date
3/9/2020 10:05:53 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE CHAPLAIN RD
Street Number
6133
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
{ <br /> Drawing Specification Number. <br /> Comment No. Number Comment Comm. Response/2nd Review Comment Response/3rd Review Comment <br /> page.subsection number <br /> Provide native backfill and compaction specification. Addressed with plan revision. N/A <br /> 23 2638-13 Trench Sections <br /> 95%backfill compaction required where trench ZB <br /> crosses or is located within a roadway and where <br /> trench is located within the dam prism. <br /> Minimum of 24"depth of cover over conduit Addressed with plan revision. N/A <br /> 24 2638-13 Trench Sections ZB <br /> encasement required.. <br /> Minimum of 12"vertical separation between Not addressed.Notes calling out 12"minimum Note calling out 12"minimum vertical clearance <br /> 25 2638-13 Trench Sections existing utilities and conduit encasement ZB vertical clerance between conduit casing and between conduit casing and existing utilities <br /> required. existing utilities required. required. <br /> Provide concrete encasement specification or clearly Addressed with plan revision. N/A <br /> 26 2638-13 Trench Sections reference standard PUD encasement specification. ZB <br /> 27 2638-13 Trench Sections Show reflective,metallic warning tape approximately ZB Addressed with plan revision. N/A <br /> 12"above concrete encasement. <br /> Provide surface restoration specification or clearly Not addressed.Note is required on plan. Addressed with plan revision. <br /> 28 2638-13 Trench Sections reference standard PUD surface restoration ZB <br /> specfication. <br /> Provide cross-section detail for conduit crossing at Partially addressed with plan revision.More detail Addressed with plan revision. <br /> 72"siphon pipe and 24"return pipe.Minimum 5 footneeded about construction method(s)near City of <br /> 29 2638-14 Layout-Dam horizontal separation between conduit trench and pipe ZB Everett piping. <br /> supports required. <br /> 30 2638-14 Layout-Dam Provide crossing detail for location where proposed ZB Addressed with plan revision. N/A <br /> conduits cross PUD telecom line. <br /> Provide asphalt restoration specifications or clearly Not addressed.Note is required on plan. Addressed with plan revision. <br /> 31 2638-14 Portal 2 Access Road reference standard PUD asphalt restoration ZB <br /> specifications. <br /> Provide native backfill and compaction specification. Addressed with plan revision. N/A <br /> 32 2638-14 Trench Sections 95%backfill compaction required where trench ZB <br /> crosses or is located within a roadway and where <br /> trench is located within the dam. , <br /> 33 2638-14 Trench Sections Minimum of 24"depth of cover over conduit ZB Addressed with plan revision. N/A <br /> encasement required.. _ <br /> Provide concrete encasement specification or clearly Addressed with plan revision. N/A <br /> 34 2638-14 Trench Sections reference standard PUD encasement specification. ZB <br /> Show existing culvert crossing Portal 2 access road Not addressed on plan sheet 2638-14.Please show Addressed with plan revision. <br /> on east side of Lake Chaplain and provide detail for the culvert crossing and related note added to plan <br /> 35 2638-14 Portal 2 Access Road conduit crossing.Proposed conduits shall be routed ZB sheet 100016377-1C for consistency. <br /> above culvert with 12"minimum vertical clearance. <br /> (Note:Approximate depth of top of culvert pipe in right <br /> wheel track is 46".) <br /> Provide typical vault detail.Vault tops and lids shall be Partially addressed with plan revision.Detail and/or Addressed with plan revision. <br /> 36 2638-14 Portal 2 Access Road traffic rated. ZB callout for vault type to be used for vault F-51844 still <br /> needed. <br /> 37 2638-14 Portal 2 Access Road Indicate if vault A-51343 will be in travel lane or ZB Addressed with plan revision. N/A <br /> roadway shoulder. <br /> Show reflective,metallic warning tape approximately Addressed with plan revision. N/A <br /> 38 2638-14 Trench Sections ZB - <br /> 12"above concrete encasement. <br /> S:1ZBrown\WFP\Projects 1PUD Fiber Line\PUD Fiber Plans 102618_Comment Log C: <br />
The URL can be used to link to this page
Your browser does not support the video tag.