My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2021-12-14
>
Address Records
>
LAKE HEIGHTS DR
>
2020
>
WATERFORD PLACE APTS
>
2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2021-12-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2021 3:31:35 PM
Creation date
3/9/2020 10:44:27 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2020
Tenant Name
WATERFORD PLACE APTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State En: ode Compliance Forms for Commercial, R2 . R3 over 3 stories and all R1 <br /> • <br /> Economizer Exceptions, cont. MECH-ECONO <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Date 4/2/201 9 <br /> ECONOMIZER EXCEPTIONS-NEW CONSTRUCTION AND ADDITIONS,CONTINUED <br /> Economizer Exp 10 Cooling equipment for dedicated server,electronic equipment or Compliance Cooling <br /> telecom switch rooms.Per building limit for this exception is System ID Capacity <br /> Exception 240,000 Btu/h cooling capacity or 10%of required building air Option (Btu/h) <br /> Summary economizer capacity,whichever is greater. Part load control <br /> required over 85,000 Btu/h.Additional requirements apply. <br /> Option a-Cooling equipment efficiency shall be 15%better than <br /> the WSEC required minimum efficiency.. <br /> Option b-Waterside economizer required.Cooling equipment <br /> efficiency shall be 5%better than the WSEC required <br /> minimum efficiency. <br /> Option c-Waterside economizer required.All cooling equipment is <br /> subject to ASHARE Standard 127. Total Claimed Exempt Capacity: <br /> Refer to Section Total building air economizer capacity(if claimed>240 kBtu/h): <br /> C403.3 for <br /> descriptions of Alternate Exp 10 Capacity Limit: <br /> economizer ECONOMIZER EXCEPTIONS-MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT <br /> provisions and System ID Alt.Strategy <br /> exceptions. For C503.4 Pre-approved design alternative to full compliance with air economizer <br /> alterations refer Exp 1 requirement.An alternative for mechanical system alterations where existing <br /> to Section building constraints make full compliance with air economizer requirement <br /> C503.4 and impractical.Provide calculations to the code official that demonstrate the <br /> Table C503.4. proposed alternate design strategy provides similar energy savings to the <br /> annual energy that would be saved by the cooling system with air economizer <br /> per C403.3. <br /> ECONOMIZER EXCEPTIONS-SIMPLE SYSTEMS Cooling <br /> C503.4 Qualifying small equipment.Per unit limit less than 33,000 Btu/h.Per System ID Capacity <br /> Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5%of (Btu/h) <br /> required building air economizer capacity,whichever is greater.Cooling 1 30,000 <br /> equipment efficiency shall be 15%better than WSEC required minimum <br /> efficiency.Not eligible:non-unitary equipment,unitary equipment installed <br /> outdoors or in mech room adjacent to outdoors,equipment installed during <br /> new construction,shell-and-core construction,or initial tenant <br /> improvement. <br /> Total Claimed Exempt Capacity: 30,000 <br /> Total building air economizer capacity(if claimed>72,000 Btu/h): <br /> Alternate C503.4 Exp 2 Capacity Limit: <br /> C503.4 Equipment that provides hydronic chilled water for chilled water terminal Cooling <br /> Exp 3 units.Equipment part load cooling efficiency(IPLV)shall be better than System ID Capacity <br /> WSEC required minimum efficiency by at least 25%.Per building limit (Btu/h) <br /> for this exception is 480,000 Btu/h cooling capacity or 20%of required <br /> building air economizer capacity,whichever is greater.Chilled water <br /> terminal units serving Group R occupancies are not included in the <br /> building capacity total. <br /> Total Claimed Exempt Capacity: <br /> Total building air economizer capacity(if claimed>480,000 Btu/h): <br /> Alternate C503.4 Exp 3 Capacity Limit: <br /> Table Compliance Options for alteration or replacement of existing System ID Equipment Compliance <br /> C503.4 mechanical cooling equipment per Table C503.4.Refer to table Type Path <br /> and all applicable table footnotes for full requirements.Applies to 2b.Split <br /> the following retrofit conditions: 1st Floor Systems>_ Option A <br /> 54,000 Btu/h <br /> Option a-Any new or replacement equipment <br /> Option b-Replacement equipment of same type with same or <br /> smaller cooling output capacity. <br /> Option c-Replacement equipment of same type with large <br /> cooling output capacity. <br /> Option d-New equipment added to existing system or <br /> replacement equipment that is different than existing <br /> being replaced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.