Laserfiche WebLink
8, it <br /> BeamChek v2018 licensed to:WOODWAY HOMES INC Reg#8101-1582 _ <br /> GREENLEAF FIRE REPAIR EXSTG.WINDOW HEADER <br /> BEDROOM 1 WINDOW Date:2/15/19 <br /> Selection (2)2x 4 HF#2 Lu=0.0 Ft <br /> Conditions NDS 2015 <br /> Min Bearing Area R1=1.9 in2 R2=1.9 in2 (1.5)DL Defl= 0.04 in <br /> Data Beam Span 3.25 ft Reaction 1 LL 548# Reaction 2 LL 548# <br /> Beam Wt per ft 2.55# Reaction 1 TL 772# Reaction 2 TL 772# <br /> Bm Wt Included 8# Maximum V 772# <br /> Max Moment 627'# Max V(Reduced) 633# <br /> IL Max Defl L/240 TL Actual Dell L/399 <br /> LL Max Dell L/360 LL Actual Defl L/642 <br /> Attributes Section(in2) Shear(in2) TL Dell(in) LL Defl <br /> Actual 6.13 10.50 0.10 `0.06 <br /> Critical 5.13 5.51 0.16 0.11 <br /> Status OK OK OK OK <br /> Ratio 84% 52% 60% 56% <br /> Fb .si Fv(psi E psi x mil Fc I psi) <br /> Values Reference Values 850 150 1.3 405 <br /> Adjusted Values 1466 173 1.3 405 <br /> Adjustments CF Size Factor 1.500 <br /> Cd Duration 1.15 1.15 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:338 Uniform TL:473 =A <br /> Uniform Load A <br /> Z . <br /> R1 =772 R2=772 <br /> SPAN=3.25 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. <br /> 6417 <br /> • IMBED <br /> -.:ITECT <br /> ilk <br /> trd i 104 .04 <br /> DEAN c DARIOTIS <br /> STATE OF WASHINGTON <br />