My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1802 RUCKER AVE 2020-03-09
>
Address Records
>
RUCKER AVE
>
1802
>
1802 RUCKER AVE 2020-03-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 11:49:28 AM
Creation date
3/9/2020 11:48:21 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
1802
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ruml <br /> TRANSMITTAL 0 FAX <br /> DAVID <br /> VANDERVORT <br /> To: Everett Public Services Department ARCHITECTS <br /> Atkentiorc Jeff Heilman <br /> AIA <br /> Fax/Address: Pages: 2 (Including cover sheet) <br /> Subject: Building Issues Date: 3/21/2017 <br /> Project C1701-006 <br /> 2 0 0 0 <br /> • Please find enclosed: FAIRVIEW AVE E <br /> Updated plans,corrections for comments dated March 1,2017. SUITE 103 <br /> SEATTLE <br /> • Remarks/Notes: WASHINGTON <br /> 9 8 1 0 2 <br /> Jeff, correction responses as follows: <br /> 206.784.1614 <br /> 1. I have added details showing how we are maintaining our required %"GWB <br /> separation between the garage and living space all the way to the underside of the FAX.7 8 4.5403. <br /> roof sheathing on details 1 &2 on sheet 05. Detail 1 shows parallel to the truss <br /> while detail 2 shows perpendicular to the truss. www.vandervort.com <br /> 2. I added a concrete landing outside of the personnel door exiting the garage on the <br /> main floor and foundation layout plans. I also added on the architectural foundation <br /> layout on sheet 04 plan note#1 stating the structural requirements. <br /> 3. Anchor bolt requirements have been added with plan note#2 below the <br /> architectural foundation layout sheet 04. <br /> 4. The general notes have been updated. They now are worded to reflect that R49 is <br /> the minimum at flat ceilings and R-38 is the minimum at vaulted ceilings and thus <br /> does not conflict with our specification. Please see change on sheet 01. <br /> 5. I have provided a sheet of details that represent all of our building assemblies <br /> represented at the bottom of sheet 03 on a new sheet 05. <br /> 6. I have revised my fire-rated assembly callout to represent an exterior wall. The new <br /> assembly is GA File No.WP-8105. See sheet 03 for revised assembly callout and <br /> sheet 05 for assembly detail. <br /> 7. I have revised my fire-rated assembly and callout to represent an exterior roof/ <br /> ceiling system GA File No. RC-2601. See sheet 03 for revised assembly callout <br /> and sheet 05 for assembly detail. <br /> 8. I have shown the insulation baffle and venting on all applicable assemblies on sheet <br /> 05. Section 3 sheet 05 shows the baffle and extents in its entirety as well as has a <br /> written description stating extents and clearance vertically above the insulation. <br /> 9. I have provided a note at all roof details on sheet 05 stating that blocking is required <br /> at roof trusses capable of resisting overturning. See detail 3 on sheet 05. <br /> 10. I have added a roof ventilation plan on sheet 04 where I have calculated the <br /> required roof venting at the ridge and eves(making sure to not have ventilation <br /> openings on the south wall.) See sheet 04 <br /> Fiona Brian O'ConnorlE[IVL <br /> (� <br /> M`'R 3 0 2017 C-7 <br /> (10/2 CITY OF EVERE 6 T <br /> Permit Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.