My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE BASE FILE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:23:14 AM
Creation date
3/20/2020 3:28:21 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1775
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr, Alfred Muller, Jr., Administrator October 8, 1963 <br /> General lospital of liverott Page 2 <br /> U. Provide an approved one hour fire separation between the hospital <br /> building and the new wing at required flours. These separations must be enclosed <br /> with one hour fire resistant construction, consisting of 2" x 4" studs spaced 16 <br /> inches on centers and covered on both sides with 5/13 inch plasterboard or its <br /> equivalent. The openings must be equipped with automatic closing or self-closing <br /> fire doors at least 13/4" thic: and covered on both sides with not less then 2e <br /> gauge sheet metal (aluminum not approved), or composite wood fire doors bearing the <br /> label of the Underwriters' Laboratories, Inc. Hood framing around the door openings <br /> must be covered with like metal 4 inches bach from the openings. Hinges must be <br /> bolted through the doors and secured to iambs with long screws in such a manner <br /> 1 as to prevent future sagging. <br /> c. Provide approved wiring to the back of the autoclave steam sterilizer. <br /> First Floor <br /> CM <br /> lO. Repair and adjust the east fire door located in the breezeway <br /> between the nurses' home and the hospital so that it will close properly. <br /> \,_. 11, Change the color of the exit globe and exit sign located on the <br /> center egress of the first floor from red to green. <br /> ((�� 12. Provide an intermediate handrail to the center of the stairway <br /> lam!located on the Colby Avenue entrance as any stairway Ut+ inches or more in width <br /> r` shall be provided with one or more intermediate handrails substantially supported, <br /> j the number and position of intermediate handrails to be such that there will be not <br /> j more than 66 inches between adjacent handrails. <br /> 13. The above regulation also applies to the stairs leading to the second <br /> Ylanding in the same egress. All stairways leading to required means of egress from <br /> the building, having three or more risers, must be equipped on both sides with <br /> approved handrails. <br /> 14. It was noted during the inspection that fabrics were draped on the <br /> oxygen cylinders. Covers of fabric or of any form of sheeting shall nat be used <br /> to cover anesthesia equipment for the reason that a cover will confine gas that <br /> may leak from a cylinder. When the cover is removed from the anesthesia machine <br /> under such conditions. a static charge may be created which could ignite the gas <br /> confined beneath the cover. Never drape an oxygen cylinder with ony material, such <br /> as hospital gowns, masks or caps. <br /> 15. Provide a metal container with cover to replace the paper barrel <br /> being used for combustible paper and cloth in the store room. <br /> 16. Replace the burned out light globe in the exit sign located in the <br /> auditorium. <br /> Provide handrails to the steps leading from th:: :.itclen to the exit <br /> located by the potato room, <br /> I <br /> 1 <br /> i <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.