My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE BASE FILE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:23:14 AM
Creation date
3/20/2020 3:28:21 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1775
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.c ptemter 0, 196`.. <br /> General Hospital of Everett, c'..?itio::s and `_terc:tioi <br /> 332, Colby 'venue <br /> Everett, hi i tor. <br /> Review of: Sol emetic Pi.:ns <br /> Pens dated: June 16, 1964 <br /> Plans Received: June 29, 1964 end June 2, 196S <br /> Items followed by citation of a section number ere requirement., c. the <br /> et;ndardo, Rules •.nl Reguletions :nd Cor.otruction Regulations of the ..t to <br /> Deportment of Health for Hospitals au adopted on January 3, 1953 and <br /> Januery 24, )9C2 by ale State Board of Health. <br /> Part A: edeeuecy o1• Brewing for Review Purp_):os. <br /> Drewings are schematic only and ..re revicue e: primerily for :.re:: reletion- <br /> ships only. <br /> Pert B: Design reetures iiot Heetinu Standards of the :;t:,te 1)o:arc of Health. <br /> 1. :several orc.as are labeled: for general storage, but :A for bull: food <br /> storage. Thin is required. ( .19.749(4)) <br /> 2. Gorb.xje facilities must be lcn oted in a separate, well-ventiletoc ream <br /> or in an outside cnclocee specs. ( .13.74 13)) <br /> Housekeeping facilities for the kitchen must be provided. <br /> :5. The plans are scheraati_ .and do not include mechanical systems. <br /> Enclosure (1), to the architect end mech.nacal engineer only, are <br /> those items which are needed on the working drawings ao that the state <br /> mechanical engineerc:n determine whether the mechanical systems ..re <br /> adequate and satisfy the standards, the regulations, :ad the _odes. <br /> ( .18.770(13)(14)) <br /> Port C: Recommendations for Imprexecrenc of Plant. <br /> 4. In general, kitchen appears to be in a satisfactory locutiun. Wny <br /> areas in the kitchen cannot be identified .end therefore cannot be <br /> evaluated. <br /> 5. It is recommended that the kind of trey service carts to be used to <br /> deliver trays to the patients' bodeides be determined early in the <br /> planning end that the troy molds-up section of the kitchen be pl.uuxxd <br /> carefully to take best advantage of the carts to be used. <br /> G. If the lob arc' is .;et up with e ::.or doing into it fres the hell <br /> between the current locotion and -ray, the yellow color coded <br /> corridors could probably be put to better design use in etructurinj <br /> the lob without losing so c*uah spate. . visit to ♦cortle est hoepitol <br /> in Seattle might be productive if the lay-out is not f araili..r to Dr. <br /> Elton and the orchite ts. Much spect wos lost to t).o lab through <br /> fire code ro ulrtio:s related to the corra set-up at Northwest <br /> Hospital. A <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.