2/21/2020 Page 2 <br /> City of Everett y/,7- <br /> 11:16:27AM <br /> INSPECTION ACTIVITY REPORT <br /> 11/4/2019 11/4/2019 BLDG DWF PARTIAL APPR eTRAKiT Inspection 11/1/2019 1:23 PM Galen Smith <br /> 08-FRAMING Request <br /> Contact Name:Galen Smith <br /> Site Address: 1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> (11/4/2019 11:43 AM DWF) <br /> Drywall,north shaft,2 layers of 5/8"type x <br /> with offset ok to cover. <br /> South shaft 1"core board install ok to cover <br /> with next layer of 5/8"drywall and will <br /> inspect offset for third layer. <br /> 11/12/2019 11/12/2019 BLDG DWF PARTIAL APPR eTRAKiT Inspection 11/8/2019 9:49 AM Galen Smith <br /> 08-FRAMING Request <br /> Contact Name:Galen Smith <br /> Site Address: 1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> (11/12/2019 1:33 PM DWF) <br /> South Mechanical Shaft-exhaust duct <br /> leading into mechanical room, 2 layers <br /> with offset. <br /> Ok to continue with framing,drywall and <br /> ceiling <br /> grid.Note leave tile out for inspection of <br /> mechanical and fire protection. <br /> 11/13/2019 11/13/2019 BLDG DWF PARTIAL APPR eTRAKiT Inspection 11/12/2019 12:14 PM Galen Smith <br /> 08-FRAMING Request <br /> Contact Name:Galen Smith <br /> Site Address:1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> (11/13/2019 11:26 AM DWF) <br /> South shaft,above ceiling box out for <br /> ducting. <br /> 1"core board installed- <br /> ok to continue with next layer of drywall. <br /> Fire protection for shaft. <br /> 11/20/2019 11/20/2019 BLDG 12-CEILING DWF NOT READY cancelled inspection 11/19/2019 11:56 AM Galen Smith <br /> GRID <br /> Contact Name:Galen Smith <br /> Site Address: 1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> 11/21/2019 11/21/2019 BLDG 12-CEILING DWF APPROVAL eTRAKiT Inspection 11/20/2019 9:08 AM Galen Smith <br /> GRID Request <br /> Contact Name:Galen Smith <br /> Site Address:1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> (11/21/2019 1:57 PM DWF) <br /> As noted-complete drywall-fire taping at <br /> smoke wall as discussed with contractor <br /> before complete cover of ceiling tile. <br /> 12/27/2019 12/27/2019 BLDG 15-FINAL DWF APPROVAL Subject to 12/20/2019 11:31 AM Galen Smith <br /> B1907-078/ <br /> K1908-007 finals. Contact Name:Galen Smith <br /> Site Address: 1321 COLBY AVE <br /> Phone:2066436779 <br /> e-Mail:galen.smith@skanska.com <br /> 2/21/2020 2/21/2020 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> 2/21/2020 2/21/2020 FIRE 02-FINAL SAG APPROVAL <br /> INSP12 CRIllfsYSTEMS <br />