Laserfiche WebLink
; `,. PUBLIC WORKS <br /> „g-ii <br /> February 12, 2014 <br /> James G. Surface <br /> 5618 100th PI. NE <br /> Marysville, WA 98270 <br /> RE: Owner: James Surface <br /> Job Address: 1517 Walnut St. <br /> Plan Check No: B1402-009 <br /> Dear Mr. Surface: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that revisions may be necessary before a permit can be issued. Please review <br /> and respond to the comments below. These comments address building issues only. Additional <br /> revisions, or additions, may be required by other departments (such as Utilities, Planning or <br /> Fire). All references refer to the 2012 International Building Code (IBC), the 2012 International <br /> Fire Code (IFC), the 2012 International Mechanical Code (IMC), and the 2012 International <br /> Energy Conservation (IECC), as amended by the State of Washington and adopted by the City <br /> of Everett. The current IBC referenced standard for accessible design is the 2009 "Accessible <br /> and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards <br /> may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction <br /> documents reflecting the corrections requested. <br /> ')( 1. Please fill in the enclosed worksheet to provide compliance with RCW 64.55. <br /> 2. Please provide all of the information that will verify compliance with the thermal <br /> envelope requirements of WSEC 2012, Chapters 3 and 4. <br /> 3. The plans should include the requirement for an automatic fire suppression system to <br /> comply with NFPA 13 R. <br /> 4. The plans should include the requirement for a monitored automatic fire detection <br /> system per City of Everett ordinance 1902-92. <br /> 5. The proposed site plan indicates 5'-0" setbacks on the right and left sides. Please <br /> address the following: <br /> A. IBC 602.1 requires one-hour fire resistive construction. <br /> B. IBC 705.5 requires these walls to be rated for exposure to fire from both sides. <br /> C. IBC 705.8 limits the area of unprotected openings in these walls to 25% of the area <br /> of the wall per story. This also includes crawl space vent openings. <br /> //2 <br /> CITY OF EVERETT•3200 Cedar Street• Everett, WA 98201 • (425) 257-8800 • Fax(425)257-8882 -_- <br />