1519 WALNUT ST 2020-04-02
>
Address Records
>
WALNUT ST
>
1519
>
1519 WALNUT ST 2020-04-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2020 4:00:52 PM
Creation date
4/2/2020 3:58:27 PM
Metadata
Fields
Template:
Address Document
Street Name
WALNUT ST
Street Number
1519
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EX.i`FANSU)f' 1Nd et Y P C" R Atst <br /> S U /)' I) 0 r t tw,,Ii <br /> Residential Building Air Leakage Test(Blower Door Test) Results <br /> Permit#: <br /> House address or lot number: i r t9 Wa'y1w SI- Arc0 <br /> City: Et).It/e-1-1" zip: 1 g 2-D f <br /> Cond. Floor Area(ft2): ) D 4 Age of house: <br /> Source (circle one): Plan Estimated Measured <br /> Results shall be reported as Air Changes per Hour at 50 Pascals(ACH50)and shall be calculated as follows: <br /> ACH50= (CFM50 x 60)/Volume <br /> Where: <br /> CFM50= Blower door fan flow at 50 Pascal pressure difference <br /> Volume=Conditioned Floor Area of the housing unit x ceiling height <br /> Blower Door Test Result: 1.4g ACH50 <br /> ___712____CFM@50Pa <br /> Ring (circle one if applicable): Open 0 B C <br /> Blower Door Fan Location: V'V <br /> }` ()VV.- Weather Conditions: Q �M� S <br /> I certify that these blower door results are accurate and determined using standard industry protocol. <br /> Q <br /> Company Name: QUI 11(�1 <br /> 07 f/�}Yn4t( <br /> S Technician: SitlA S� C IBJ <br /> Technician Signature: Date: I I 'lb Phone Number: j-t? -g727 <br /> .4.--- -2 <br /> 2015 Washington State Energy Code reference: <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not <br /> exceeding 5 air changes per hour.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 <br /> Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report <br /> of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing <br /> shall be performed at any time after creation of all penetrations of the building thermal envelope.Once visual <br /> inspection has confirmed sealing(see Table R402.4.1.1),operable windows and doors manufactured by small business <br /> shall be permitted to be sealed off at the frame prior to the test. <br /> CF1EDVii\ <br /> NOV 16 2018 j.-_,/ <br /> CITY OF EVERETT <br /> Permit Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.