Laserfiche WebLink
FLOORS <br /> V <br /> / <br /> / <br /> i HOLD-DOWN OR SIMILAR <br /> TENSION DEVICE <br /> FLOOR SHEATHING NAILING AT <br /> 6"MAXIMUM ON CENTER TO <br /> JOIST WITH HOLD-DOWN / <br /> TILL, 11110- • .i. <br /> Z + + +=4. Agit <br /> ' + + + <br /> AgiA <br /> / <br /> FLOOR JOIST 1 / <br /> / \ DECK JOIST <br /> // <br /> V <br /> For SI: 1 inch=25.4 mm. <br /> FIGURE 507.2.3(1) <br /> DECK ATTACHMENT FOR LATERAL LOADS k <br /> SHEATHING <br /> NOTE: SIDING <br /> THIS DETAIL IS APPLICABLE <br /> WHERE FLOOR JOISTS ARE FLASHING FOR <br /> PARALLEL TO DECK JOISTS. II: <br /> WATER TIGHTNESS <br /> DECKING <br /> 11.11111112 'M <br /> • ISI I�,' APPROVED JOIST HANGERS <br /> 2"MIN. NO. '� 2x LEDGER WITH FASTENERS <br /> . ll IN ACCORDANCE WITH TABLE R507.2 <br /> ■ III 11111111 <br /> ill <br /> HOLD-DOWN DEVICE MIN 750 LB.CAPACITY <br /> FLOOR JOISTS AT 4 LOCATIONS, EVENLY DISTRIBUTED <br /> ALONG DECK AND ONE WITHIN 2"OF EACH <br /> END OF THE LEDGER. HOLD-DOWN DEVICES <br /> SHALL FULLY ENGAGE DECK JOIST PER <br /> HOLD-DOWN MANUFACTURER. <br /> A FULLY THREADED 3/8"DIAMETER LAG <br /> SCREW PREDRILLED W/MIN.3"PENETRATION <br /> TO CENTER OF TOP PLATE,STUDS,OR HEADER. <br /> t <br /> For SI:1 inch=25.4 mm,1 foot=304.8 mm. <br /> FIGURE R507.2.3(2) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> 61.3 <br /> 152 2015 INTERNATIONAL RESIDENTIAL CODES <br />