er3/2/203 City of Everett Page 17 <br /> 7:41:15AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E1911-150 Site Address 10307 1ST DR SE <br /> Applied 11/25/2019 Applicant KING LEX Lot <br /> Approved 11/25/2019 Owner BERUTTI ANDREA Block <br /> Issued 11/25/2019 Contractor SMART ENERGY TODAY INC(ELEC) Tract <br /> Parent Permit No. B1911-031 Description ELECTRICAL FOR SOLAR PANEL INSTALL <br /> Notes **MANUFACTURERS SPECS SHOULD BE ON JOBSITE FOR THE BUILDING INSPECTORS TO <br /> REFER TO** <br /> Scheduled Completed Tune Inspector Result Remarks Inspector's Comments <br /> 1/14/2020 1/14/2020 ELEC 09-FINAL SKB NOT READY eTRAKiT Inspection 1/7/2020 3:27 PM SMART ENERGY <br /> Request TODAY INC(ELEC) <br /> She is a special ed teacher and has to take <br /> the day off,Please make sure that we can do <br /> this day otherwise we we would have to <br /> wait another month.Our company contact <br /> number for us installers is,3604013047 ext <br /> 3224 This is going to be along B1911-031 <br /> for electrical Final <br /> Contact Name:Andrea Burretti <br /> Site Address:10307 1ST DR SE 10307 1st <br /> Dr SE,Everett,Washington 98208 <br /> Phone:8478526786 <br /> e-Mail:Hector.f@smartenergytoday.net <br /> (1/14/2020 3:19 PM SKB) <br /> Service entrance conductors cannot travel <br /> more than 15 feet through the building. <br /> Properly ground the grounded conductor in <br /> the service disconnect.Replace the LL <br /> condulet that has been drilled and violated <br /> the UL listing.Have one line diagram <br /> paperwork available at the time of <br /> inspection. <br /> 1/21/2020 1/21/2020 ELEC 09-FINAL SKB NOT READY eTRAKiT Inspection 1/15/2020 2:44 PM SMART ENERGY <br /> Request TODAY INC(ELEC) <br /> Is a teacher and is going to have room mate <br /> at home <br /> Contact Name:Andrea Burretti <br /> Site Address: 10307 1st Dr SE,Everett, <br /> Washington 98208 <br /> Phone:8478526786 <br /> e-Mail:Hector.f@smartenergytoday.net <br /> (1/21/2020 2:31 PM SKB) <br /> Corrections not completed. <br /> 2/5/2020 2/6/2020 ELEC 09-FINAL SKB OTHER Cancelled by 1/27/2020 4:14 PM SMART ENERGY <br /> contractor TODAY INC(ELEC) <br /> Contact Name:SMART ENERGY TODAY <br /> INC(ELEC) <br /> Site Address: 10307 1ST DR SE <br /> Phone:8884058689 <br /> e-Mail:lex.k@smartenergytoday.net <br /> 2/7/2020 2/7/2020 ELEC 09-FINAL SKB CORRECTION (2/7/2020 2:12 PM SKB) <br /> provide updated one line diagram.Replace <br /> the LB that was drilled out.There are 2 30 <br /> amp single pole breakers in the panel on <br /> wires not rated for 30 A correctly ampacity <br /> on the breakers. Repair or replace the <br /> Service entrance conductors where pinch <br /> clamps were installed I can see copper <br /> through the insulation. <br /> INSP12 CRWs YS TEMS <br />