<br /> - - — - — — I '
<br /> BUILDER NOTE: -
<br /> BUILDER SHALL VERIFY ALL WINDOW COUNTS AND SHALL VERIFY THAT ALL ROUGH OPENING SIZES SHALL ACCOMUDATE SCHEDULED WINDOWS PRIOR TO ORDERING ANY WINDOWS. BUILDER SHALL NOTE
<br /> STEP 1 : INSTALL SILL ' ' THAT THE NUMBERS BY EACH WINDOW ARE TAGS THAT IDENTIFY THE WINDOWS SIZE. A 3050 WINDOW IS A WINDOW THAT IS 3'-0" WIDE BY 5'-0" HIGH. BUILDER SHALL NOTE THAT ALL WINDOW
<br /> FLASHING PAPER AT ��Tlndow O enin Schedule MANUFACTURERS SIZES AND ROUGH OPENINGS MAY VARY FROM THE DIMENSIONS GIVEN BELOW. BUILDER SHALL HAVE WINDOW MANUFACTURER VERIFY THAT BEDROOM EGRESS WINDOWS MEET EGRESS
<br /> BOTTOM OF OPENING, � SAFETY REQUIREMENTS.
<br /> STAPLE ALONG TOP EDGE
<br /> 3/8" FROM TOP OF PAPER •
<br /> ��',�E BOTTOM EDGE Sin�le Hun� Windows Slider Windows Gara�e Door .
<br /> ALL TRIM SHOWN IS AT ,
<br /> UNATTACHED FOR WATER EXTERIOR OF WINDOW
<br /> RESISTENT BARRIER TO GO (TYP) - SEE TRIM �
<br /> s" MIN UNDERNEATH FLASHING A B C, NOTES BELOW C E �F G H 16' W x 7' H PAINTED METAL GARAGE DOOR W/
<br /> O
<br /> O GLAZED OPENINGS AS SHOWN
<br /> � PAPER
<br /> O
<br /> O
<br /> STEP 2: INSTALL JAMB ,
<br /> FI�,SHING PAPER AT SIDES 02 � � �� � �� �
<br /> OF OPENING, TWO ROWS OF � �
<br /> STAPLES DO NOT STAPLE - —
<br /> s" MIN BELOW ROW OF STAPLES AT f _ ❑ ❑ ❑❑ ❑ ❑❑ ❑ �
<br /> SILL FLASHING PAPER 2536 20�6 — 6040 5040 5036 HORIZ. SLIDER
<br /> CARL J. COLSON — ARCHITECT PLLC
<br /> LEAVE BOTTOM EDGE 2s4o _ _ _ __
<br /> UNAl-I-ACHED FOR WATER 5�w X 2 H WINDOW � � ❑� ❑ ❑ ❑ ❑ 23623 20th AVENUE W BOTHELL,
<br /> RESISTENT BARRIER TO GO 10 S.F. •
<br /> �� WASHINGTON 98021 (425) 806 3'703
<br /> 12" MA •
<br /> UNDERNEATH FLASHING SINGLE-HUNG SINGLE HUNG SINGLE HUNG HORIZ. SLIDER HORIZ. SLIDER HORIZ. SLIDER HORIZ. SLIDER ❑ ❑ a❑ ❑ ❑❑ ❑ �
<br /> Pl ?ER » , „ , >, , , ,> > ,> ,
<br /> NUTE: FLASHING PAPER TO 2�6 W x 4'0"H 2 6" W x 3'6 H 2 0 W x 3 6" H 7 6 W x 4 0 H WINDOW 6'W x 4'H WINDOW 5'W x 4'H WINDOW 5'W x 3'6"H WINDOW
<br /> BE COATED VAPOR WINDOW 9 S.F. 7 S.F. 30 S.F. 24 S.F. 20 S.F. 17.5 S.F.
<br /> �� BARRIER REINFORCED 11 s.F. PROJECT:
<br /> �2" MAX GRADE A OR B. 1 {' "
<br /> ' ' 8' W x 7' H PAINTED METAL GARAGE �� Ll � LS
<br /> DOOR W/ GLAZED OPENINGS AS SHOWN �
<br /> �.�
<br /> STEP 3: INSTALL
<br /> "NAIL-ON" WINDOW I J K Skyli�ht Gable Vents �
<br /> - � „ � � � Sln le-Famil
<br /> , � O � � �❑
<br /> O _
<br /> O „
<br /> � FIXED 24 x 36 » VELOPER BUILDERS � �
<br /> � � 20 x 30 PAINTED POLY AT DE / ,
<br /> I � \ I 2030 SAFE YHGLAZINGOW-E GABLE ROOF VENTS (W/ OPTI�N, A NON-VENTING ❑ ❑ ❑❑
<br /> � INSECT SCREENING). FLASH • ,
<br /> 6 S.F. USEDE AD QUATE A�IC Re sl enc e s
<br /> I � � / I/ AT DEVELOPER/BUILDERS OPTION, OPENING PER WINDOW VENTING IS PROVIDED
<br /> � � // / �� , „ OPENING FLASHING DETAIL. ❑ ❑ ❑❑ "
<br /> � � � /� 4040 4036 3636 — SKYLIGHT MAY B E USED X 4 0 TRIM SIM. TO WINDOW THROUGH EAVE VENTS
<br /> / AND RIDGE VENTS 9909 2nd Avenue W
<br /> � ❑ � 0� Everett, WA 98204 ,
<br /> STEP 4: INSTALL HEAD
<br /> FIASHING PAPER OVER HORIZ. SLIDER HORIZ. SLIDER HORIZ. SLIDER �
<br /> TOP OF WINDOW 4'W x 4' H WINDOW 4'W x 3'6"H WINDOW 3'6" W x 3'0"H WINDOW .
<br /> � AD 16 S.F. 14 S.F. 12 s.F. CLIENT:
<br /> �1�. AT WINDOW HE
<br /> METAL FLASHING: INSTALL IT City B�ul.ders NW
<br /> / // OVER THE WINDOW HEAD
<br /> FLASHING PAPER, aN� l 410148th St. NE
<br /> // / C THE WATER ������ �� � ���� le �1111gtOri, WA 98223 �
<br /> P LA E � �.i.
<br /> Doo� c e
<br /> /i �ii � .
<br /> RESISTANT BARRIER OVER 3068 DOOR W/ 14" WIDE
<br /> THE FLANGE OF THE METAL W I N D OW S I LLG UAR D / FLAS H I N G I N STA��ATI 0 N 5/4 x 6 HEAD TRIM SIDELITE (DBL. GLAZED W/ 1 x 5 HEAD
<br /> FLASHING CONTRACTOR SHALL INSTALL ALL WINDOWS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. PRIOR TO INSTALLING WINDOW IN ROUGH OPENING, TRIM ��� � ���,,T
<br /> „ „ 5 4 x 4 JAMB TRIM SAFETY GLASS) 1 x 4 JAMB 1 �
<br /> CONTRACTOR SHALL INSTALL JAMSILL GUARD ( AVAILABLE AT PELLA NORTHWEST IN BELLEVUE 425-455-5550 OR WWW.JAMSILL.COM) WHICH !S � EXTERIOR DOOR FLASHING TRIM
<br /> A VINYL WINDOW SILL DAM TO PREVENT WATER FROM ENTERING WALL CAVITY (INSTALL PER MANUFACTURERS INSTRUCTIONS). CONTRACTOR SHALL 9-LITE VISION PANEL INSTALL "JAMSILL GUARD" �� � �
<br /> THEN INSTALL WINDOW WRAP FLASHING PER WINDOW WRAP DETAIL ON THIS SHEET. ALL WINDOWS SHALL HAVE METAL DRIP FLASHING INSTALLED WITH SAFEI�Y GLASS DOOR SILL PAN FLASHING AT 4 PANEL SOLID �
<br /> s" M�N LAP WATER RESISTANT AT HEAD OF WINDOWS. ALL EXTERIOR DOORS ( PER WOOD DOOR
<br /> I BARRIER VERTICALLY 6" ALL WINDOWS SHALL HAVE METAL DRIP FLASHING AT WINDOW HEADS. ALL HARDWARE MANUF. INSTRUCTIONS). ALL HARDWARE ��T � �� �
<br /> SELECTION BY INSTALL JAMB & HEAD SELECTION BY 1�
<br /> ���"'� � ° BO IDEWOOD PANELS DOOSRSNPERTWINDOWTERIOR BUILDER •
<br /> ,, ,i CONTRACTOR SHALL VERIFY ALL WINDOW EGRESS WINDOWS �
<br /> ��� � i LAP WATER RESISTANT QUANTITIES AND SIZES BEFORE ORDERING ALL SLEEPING ROOMS ARE REQUIRED TO HAVE EGRESS WINDOWS. THE WINDOWS SHALL FLASHING DETAIL ON THIS � � � � ,
<br /> �' � HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE FEEf. THE MIN. NET SHEET
<br /> � BARRIER HORIZONTALLY -
<br /> ��' i „ WINDOW SERIES CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24" AND THE MIN. NET CLEAR 7jr,1 �
<br /> ��� / i / 2 MIN ALL WINDOWS SHALL BE MILGRAD VINYL WINDOWS - OPENABLE WIDTH DIMENSION SHALL BE 20". ALL EXIT WINDOWS SHALL HAVE SILLS NO s � � � � ���
<br /> - / i - CLEAR GLASS WITH A ENTRY DOOR ENTRY DOOR W/ SIDELITES INTERIOR DOORS
<br /> I i CLASSIC SERIES WITH LOW E / HIGHER THAN 44 ABOVE THE FINISH FLOOR.
<br /> � i SLIP LOWER END OF Refer to Floor Plan Refer to Floor Plan For Refer to Floor Plan ALL PLAN TYPES HAVE THE SAME DOOR &
<br /> i / JAMB FLASHING PAPER MIN. U VALUE OF 0.40. WINDOW SUPPLIER SHALL VERIFY ALL EGRESS WINDOWS MEET EGRESS REQUIREMENTS Sizes & Swin Direction For Sizes & Swin WINDOW SCHEDULES �
<br /> i / ORDER FROM CONTRACTOR. For Sizes & Swing 9 9
<br /> i / / AND SILL FLASHING BEFORE ACCEPTING
<br /> / Direction (42 s.f.) Direction
<br /> i /
<br /> , / � PAPER OVER WATER NOTES:, 21 s.f.
<br /> i � � 1 x 5 HEAD 1 x 5 HEAD TRIM
<br /> � RESISTANT BARRIER AT 1. ALL WINDOWS SHALL BE VINYL WINDOWS WITH DOUBLE GLAZING 9-LITE VISION PANEL
<br /> METAL FLASHING C�? WINDOW TRIM HEAD BLOCKING AT WINDOWS TRIM `'��� �- '�'� �
<br /> i � THE WINDOW SILL (1/2" MIN. AIR SPACE) WITH SAFETY GLASS � �F �����g ��� ��
<br /> i � PROVIDE BLOCKING � 1 x 4 JAMB 1 x 4 JAMB TRIM � ��� � ��r
<br /> � � 2. ALL OPERABLE WINDOWS SHALL HAVE INSECT SCREENS. �SEE BLOCKING NOTE � RIGHT , €r' i" �2� �
<br /> i EACH END OF WINDOW TRIM � - .
<br /> �� � / 5/4x6 PTD. WOOD TRIM � HEAD HEADERS FOR 1 STUD � 4� ' ��
<br /> � TWO LAYERS OF SAFETY GLAZING � SPACE TO ACT AS 4 PANEL SOLID 4 PANEL METAL DOOR
<br /> i � WATER RESISTANT ALL GLASS LOCATED IN AN AREA WHICH THE INTERNATIONAL � � SCHECULED WINDOW OPENING BACKING FOR WOOD DOOR 1-3 4" THICK F , / 6,���v �
<br /> ( / ) � � ���� � ����� ' �
<br /> i� BARRIE R P E R B U I L D I N G R E S I D E N T I A L C O D E C O N S I D E R S H A Z A R D O U S S H A L L B E S A F E T Y / � PTD. 5/4x 4 W O O D T R I M C�? S I D E J A M B I N S T A L L A T I O N O F (1 -3/4" T H I C K) �� 4
<br /> � ��,(���+�1�1��iN��e� ' � �:
<br /> � CODE REQUIREMENTS GLAZING. THESE INCLUDE: �/ \� 2 x PTD. CEDAR SILL W/ SLOPE VAIANCES / CURTAIN W/ CLOSER ���� --�-y-�" ���.uN �� �
<br /> A.) ALL GLAZING IN DOORS AND GLAZING IN ANY OPENING ROD ASSEMBLIES AND
<br /> ADJACENT TO A DOOR WITHIN A 24" ARC OF EITHER VERTICAL EDGE 2" OVERHANG ON SILL WEATHERSTRIPPING �
<br /> OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM 5/4 x 4 PTD. WOOD TRIM BELOW SILL ALL HARDWARE ALL HARDWARE
<br /> FLEXIBLE FLASHIf�'G MATERIAL EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WINDOW TRIM AND DOOR OPENING TRIM SELECTION BY SELECTION BY BUILDER PERMIT SET NOTIFICATION
<br /> FLEXIBLE WINDOW�DOOR�OPENING WALKING SURFACE. ALL TRIM SHALL BE CEDAR PRIMED BUILDER
<br /> FLASHING SHALL BE GRACE VYCOR V40 B.) TUB / SHOWER ENCLOSURES. INCLUDING BACK & ENDS AND PAINTED This set of drawings is being issued as a Permit Set and
<br /> WEATHER BARRIER STRIPS BY W.R. ( � INTERIOR DOOR EXTERIOR DOOR TO PATIO ./ DECK DOORS is subject to change and adding of additional drawings
<br /> GRACE C0. OBSCURE GLAZING GARAGE STORAGE Refer to Floor Plan or info9rmatP n as required by review by City of Everett
<br /> TO GARAGE Buildin De artment.
<br /> DUE TO THE TIGHT PROXIMITY OF BUILDINGS, CERTAIN WINDOWS Refer to Floor Plan Refer to Floor Plan For Sizes & Swing
<br /> �irection DO NOT USE THIS DRAWING FOR
<br /> � � SHALL HAVE OBSCURE GLAZING. ALL BATHROOM WINDOWS SHALL For Sizes & Swing For Sizes & Swing CONSTRUCTION UNLESS THIS DRAWING HAS �
<br /> 1 ��Tindow Flasl�n HAVE OBSCURE GLAZING. Direction Direction ;
<br /> A CITY OF EVERETT BUILDING DEPARTMENT
<br /> "APPROVED" STAMP UPON COMPLETION OF
<br /> . , THE PERMIT REVIEW PROCESS.
<br /> Alicat�on Do not use for bidding or estimating purposes unless �
<br /> �p authorized by Owner / Developer. Developer / Builder
<br /> shall be responsible for construction crews are supplied
<br /> Not To Scale
<br /> with all approved and most current construction
<br /> documents. .
<br /> INSTALL MEMERANE FLASHING � 4-�s-os PLAN B & C ISSUED FOR PERMIT
<br /> PER APP�ICATION DETAIL PRIOR '
<br /> CEDAR SIDING TO AND DURING WINDOW . 2 4-2s-os PLAN A ISSUED FOR PERMIT
<br /> � � BUILDING PAPER INSTALLATION �
<br /> CEDAR SIDING � �• VINYL WINDOW PER SCHEDULE
<br /> II � II ', � ,
<br /> BUILDING PAPER �� PLYWOOD SHEATHING PAINTED MDF SILL
<br /> I PLYWOOD SHEATHING �I � ��� �
<br /> I I SEALANT �� � ,� �� � - .
<br /> METAL FLASHING BATT INSULATION (R-21) SEALANT AND BA(;KER ROD NR. DATE REVISION
<br /> BATT INSULATION (R-21) N (� "' ' 2 x PRINED & PAINTED *C*O*P*Y*R*I*G*H*T*
<br /> (1� LAYER OF 1�2" GWB � (1) LAYER OF GWB � „ � ',�� 'I CEDAR SILL W� SLOPED TOP gns incorporated herein as an
<br /> I I 22 5/4 x4 PAINTED CEDAR These documents,the ideas and desi
<br /> �� 5�4 x 6 PAI NTED CEDAR WOOD WOOD TRIM W� DRIP EDGE instrument of service and shall remain the property of Car11.Colson-
<br /> I FLAS H I N G M EM B RAN E P ER I TR I M , » Arclutect PLLC and are solely for use on the residential project(City
<br /> � I �1� LAYCR OF 1�2 GWB Li hts on 2nd Ave.W Everett,WA. These files ma not be used on
<br /> I APPLICATION DETAIL FLASHING MEMBRANE PER I g � ' y ;
<br /> II `''� � HEADER PER STRUCTURE '�,; � APPLICATION DETAIL � BATT INSULATION (R-21� anyotherprojectsnormaytheybetransmittedelectronicallywithout
<br /> I • ,, I express permission of architect.They are not to be used by the client or `�'
<br /> � 2x6 PRIMED & PAINTED _ HEADER PER STRUCTURE i PLYWOOD SHEATHING
<br /> � any other party or entity on this ar other projects,in whole or part,or as
<br /> CEDAR WOOD TRIM W� , „ PAINTED MDF TRIM & CASING anextensiontothisprojectexceptbyagreementinwritingwith
<br /> .:,,.;..
<br /> , , I DRIP EDGE , , j� j � I METAL FLASHING appropriate fmancial compensation to Carl J.Colson-Architect PLLC
<br /> .,.; ..:. . .. . ,•. ', � � �p
<br /> � � ,� , �� / ,�� VINYL WINDOW - SEE Copyright 2008 Carl J.Colson-Architect PLLC, O
<br /> VINYL WINDOW PER SCHEDULE BUILDING PAPER 1`j" /''� q �-�� 7�`�� Allrightsreserved
<br /> �+. 7 I t.^� ��.� , �.�3 >_,�9 9 �
<br /> WINDOW SCHEDULE FOR TYPE PAINTED CEDAR SIDING
<br /> i`����/i��'s'��_f �_�;:�' ,- -=:�i�a���
<br /> CEDAR WINDOW SILL BELOW
<br /> METAL FLASHING � r�
<br /> , . • • . • PERMIT DRA INGS ��� � � �I� JL � � �
<br /> m Flashln Th�s note applies only to the archit ctural drawing prepared by Carl J. Colson — The Builder shall be responsible for developing construction details necessary The Architect has not been contracted to perform Construction Administration
<br /> ��Ilndow Head Flashln ��I1ndovU a b ��Tlndow Sill
<br /> Architect PLLC for Citv Builders NW (the Owner/Developer/Builder) for the Citv Lights ta construct a weathertight, durable building. services or Construction Observation services for this project and is not liable
<br /> " ' " single—family residential development project at 9909 2nd Ave W Everett. WA. All flashing, weatherproofing, raofing, and waterproofing details and or responsible for determining adequacy of construction of building envelope
<br /> �� � �� _ ff � f� This architectural drawing is prepare as a part of the Permit Set of drawings (along construction of these detail assemblies are the full and camplete or details. ;
<br /> _ 1 —O 3 — 1 —0 3 — 1 —0 with structural drawings provided by structural engineer) for the Owner/Developer/8uilder responsib:lity of the Owner/Developer/Builder and these details shall be The Owner/Developer/Builder shall be responsible for inspecting and verifying o s,•
<br /> 3 for this project only. All details, not s, and drawings shown are for Permit purposes only constructed per manufacturer requirements, building code requirements, and that all flashing, weatherproofing, roofing, and waterproofing details are built )
<br /> and do nat constitute the full set of details required to construct this project. accepted Industry Standards for performance. correctly and meet Owner/Developer/Builder ❑pproval and accepted industry � �
<br /> standards before being covered by subsequent construction work.
<br />
|