My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9606 19TH AVE SE PREMIER STORAGE Geotech Report 2022-10-25
>
Address Records
>
19TH AVE SE
>
9606
>
PREMIER STORAGE
>
Geotech Report
>
9606 19TH AVE SE PREMIER STORAGE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:18:25 PM
Creation date
4/23/2020 12:47:20 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9606
Tenant Name
PREMIER STORAGE
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Premier Storage Everett, LLC ES-2432 <br /> June 26, 2012 Page 8 <br /> Revised June 28, 2012 <br /> Foundations <br /> Based on the results of our study, the proposed storage structures can be supported on <br /> conventional spread and continuous footings bearing on competent native soils, competent <br /> existing fill soils, re-compacted native soils, or structural fill. Due to the presence of up to about <br /> seven feet of loose fill, footings for the new buildings should be overexcavated a minimum of <br /> four feet below the bottom of the footing elevation and grades restored with structural fill. <br /> ESNW should observe the overexcavation to confirm conditions and provide additional <br /> recommendations for the foundation subgrade support. Additional depths of overexcavation <br /> may be necessary depending on the soil conditions observed during construction. Where loose <br /> or unsuitable soil conditions are exposed at foundation subgrade elevations, compaction of the <br /> soils to the specifications of structural fill, or overexcavation and replacement with structural fill, <br /> may be necessary. Organic material exposed at foundation subgrade elevations must be <br /> removed and grades restored with structural fill. <br /> Provided foundations will be supported as described above, the following parameters can be <br /> used for design of new foundations: <br /> • Allowable soil bearing capacity 2,500 psf <br /> • Passive earth pressure 350 pcf (equivalent fluid) <br /> • Coefficient of friction 0.4 <br /> A one-third increase in the allowable soil bearing capacity can assumed for short-term wind and <br /> seismic loading conditions. The above passive pressure and friction values include a factor-of- <br /> safety of 1.5. With structural loading as expected, total settlement in the range of one inch and <br /> differential settlement of about one-half inch is anticipated. The majority of the settlements <br /> should occur during construction, as dead loads are applied. <br /> Seismic Design Considerations <br /> The 2009 International Building Code specifies several soil profiles that are used as a basis for <br /> seismic design of structures. Based on the soil conditions observed at the test sites, Site Class <br /> C, from table 1613.5.2, should be used for design. In our opinion, the site soils have a low <br /> susceptibility to liquefaction based primarily on the lack of shallow groundwater and the density <br /> of the underlying native soil. <br /> Earth Solutions NW, LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.