My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST DELTA HOTEL 2020-05-04
>
Address Records
>
PINE ST
>
3105
>
DELTA HOTEL
>
3105 PINE ST DELTA HOTEL 2020-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:37:07 AM
Creation date
5/4/2020 11:28:11 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
DELTA HOTEL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Envelope Summary ENV-SUM <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Info 'Project Title: Everett Delta Hotel Date 09/19/2017 <br /> liance forms Applicant Information. Provide contact information for individual who can For Building Department Use <br /> Comp <br /> Co not require a respond to inquiries about compliance form information provided. <br /> password to use. Company.Name: Murphy varey <br /> Instructional and an Com Address: <br /> calculating cells are Company 910 Lenora Street,Suite S207,Seattle,WA 98121 <br /> write-protected. Applicant Name: David Murphy <br /> Applicant Phone: 206-341-9875 <br /> Applicant Email: dmurphy@murphyvarey.com <br /> Project Description ❑ New Building 2 Addition El Alteration <br /> Occupancy Type 0 All Commercial 0 Group R-All R1 and R2,R3,R4 over 3 stories QO <br /> Selection required to enable forms. <br /> Envelope Compliance Path p Prescriptive 0 Component Performance <br /> Selection required to enable forms. <br /> Component Performance <br /> O Standard 0 Change of Occupancy/Conditioning 0 <br /> Calculation Type <br /> Selection required to enable ENV-UA ❑ Additional Efficiency Package Option-C406.8 Enhanced Envelope <br /> and ENV-SHGC forms. To comply,demonstrate building thermal envelope performance is 15%lower than the Target UA. <br /> ❑ Air barrier testing per Section C402.5.1.2 ❑ Air barrier testing not required <br /> included in project scope <br /> Air Barrier Testing ❑ Additional Efficiency Package Option-C406.9 Reduced Air Infiltration <br /> To comply,demonstrate that measured air leakage of building envelope does not exceed 0.25 <br /> cfm/ft2(air barrier surface area)under test pressure of 0.3 inch w.g. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> Prescriptive Path-Enter values for (rough opening) divided by Wall Area times 100 equals Fenestration <br /> vertical fenestration,skylights,gross walls 368.0 _ 1515.0 X 100 = 24.3% <br /> and roof on this ENV-SUM worksheet. <br /> Component Performance-Enter values Gross Exterior Roof <br /> in ENV-UA and/or ENV-UA-GROUP-R Total Skylight divided by Area times 100 equals %Skylight <br /> worksheet. These values auto-fill from <br /> ENV-UA and are write-protected on ENV- 0 .0 - 0.0 X 100 = <br /> Vertical <br /> Fenestration VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Compliance Area <br /> Skylight Area <br /> Vertical Fenestration 0 High performance fenestration U-factors and SHGC per C402.4.1.3 <br /> Alternates 0 Dedicated outdoor air system per C402.4.1.4 and C403.6 <br /> Show locations of qualifying daylight zone 0 In buildings z 3 stories,25%or more of NET floor area is in daylight zones per C402.4.1.1 <br /> areas and ft2 on project plans. <br /> 0 In buildings<3 stories,50%or more of CONDITIONED floor area is within daylight zones per <br /> For Daylight Zone Area Calculations- C402.4.1.1 <br /> a)Sidelight areas include primary+ Daylight Zone Calculations <br /> secondary daylght zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight Toplight Daylight Percent Daylight <br /> b)Include overlapping toplight and Not Selected.No Calculations Required Zone Area Zone Area Zone Area <br /> sidelight daylight zone areas under <br /> Toplight. <br /> c)Refer to Chapter 2 for net floor area <br /> Spaces in Single Story List all enclosed spaces that exceed 2,500 ft2,have ceiling height greater than 15 ft,and are space <br /> Building Requiring Skylights types required to comply with this provision. <br /> Code requires a minimum of 50%of the floor Space Area(ft2) DLZ Area(ft2) SRR or Aperature Exception <br /> area to be within a skylight daylight zone for <br /> snecific snare tvnes.Refer to 0402.4-2 for ..- <br /> /16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.