My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST DELTA HOTEL 2020-05-04
>
Address Records
>
PINE ST
>
3105
>
DELTA HOTEL
>
3105 PINE ST DELTA HOTEL 2020-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:37:07 AM
Creation date
5/4/2020 11:28:11 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
DELTA HOTEL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Requirements Summary, pg 1 ENV-REQ <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Minimum Requirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration.Refer <br /> for Prescriptive Compliance to Tables C402.1.3,C402.1.4 and C402.4 in the 2015 WSEC for important footnotes that apply to <br /> these tables. Refer to Section C402 for all applicable requirements that apply for each envelope element <br /> type and applicable exceptions. Refer to Section C410 for all applicable information for refrigerated <br /> spaces. <br /> Table C402.1.3 Notes 1,7 Table C402.1.4 Notes 1,2 <br /> Prescriptive Path Insulation Minimum R-Value Assembly Maximum U-factor <br /> Occupancy Group All Other Group R All Other I Group R <br /> Opaque Elements <br /> Roofs <br /> Insulation Entirely above Deck R-38 c.i. _ R-38 c.i. U-0.027 U-0.027 <br /> Metal Building(with thermal spacer block)Note 3 R-25+R-11 Ls R-25+R-11 Ls U-0.031 U-0.031 <br /> Attic and Other R-49 R-49 U-0.021 U-0.021 <br /> Joist or single rafter R-49 R-49 U-0.027 U-0.027 <br /> Walls,Above-grade <br /> Mass R-9.5 c.i.Note 6 R-13.3 c.i. U-0.104 Note 6 U-0.078 <br /> Mass transfer deck slab edge No R-Value for prescriptive compliance U-0.200 U-0.200 <br /> Metal Building R-19 c.i. R-19 c.i. U-0.052 U-0.052 <br /> Steel Framed R-13+R-10c.i. R-19+R-8.5 c.i. U-0.055 U-0.055 <br /> Wood Framed and Other R-21 w/int.frame R-21 w/int.frame U-0.054 U-0.054 <br /> Below Grade Wall Note a Same as above grade Same as above grade <br /> Floors <br /> Mass R-30 c.i. R-30 c.i. U-0.031 U-0.031 <br /> Steel Joist R-38+R-10 c.i. R-38+R-10 c.i. U-0.029 U-0.029 <br /> Wood Framed and Other R-30 R-30 U-0.029 U-0.029 <br /> Slab-On-Grade Floors <br /> Unheated R-I0 for 24 in.(from top of slab) F-0.54 F-0.54 <br /> Heated Note 5 R-10 perimeter&under entire slab F-0.55 F-0.55 <br /> Opaque Doors <br /> Swinging No R-Value for prescriptive compliance U-0.37 U-0.37 <br /> Nonswinging(Roll-up or sliding) R-4.75 I R-4.75 U-0.34 U-0.34 <br /> Table C402.4-0-30%of wall area,or <br /> 30%-40%per Section C402.3.1.1 DLZ Section C402.3.1.3 High Performance <br /> or Section C402.3.1.4 DORS Fenestration Option-0-40%of wall area <br /> Fenestration Assembly Maximum U-factor Notes 1,2 <br /> Vertical Fenestration <br /> Nonmetal framing U-0.30 U-0.30 U-0.28 U-0.28 <br /> Metal framing(fixed) U-0.38 U-0.38 U-0.34 U-0.34 <br /> Metal framing(operable) U-0.40 U-0.40 U-0.36 U-0.36 <br /> Entrance doors U-0.60 U-0.60 U-0.60 U-0.60 <br /> Skylights <br /> Skylights U-0.50 I U-0.50 U-0.50 I U-0.50 <br /> Fenestration Assembly Maximum SHGC Factor <br /> Vertical Fenestration PF<0.2:north-SHGC�.53; PF<0.2:north-SHGC�.46; <br /> all other SHGC=0.4 all other SHGC�.35 <br /> 0.2 5 PF<0.5:north-SHGC-0.58; 0.2 5 PF<0.5:north-SHGC-0.51; <br /> all other-SHGC-0.48 all other-SHGC-0.42 <br /> PF z 0.5:all orientations-SHGC-0.64 PF z 0.5:all orientations-SHGC-0.56 <br /> Skylights SHGC-0.35 SHGC-0.35 <br /> C410.2 Refrigerated Spaces Insulation Insulation Minimum R-Value Assembly Maximum U-factor <br /> Freezers-Walk-in and Warehouse <br /> Roof/Ceiling R-32 U-0.030 <br /> Wall R-32 U-0.030 <br /> Door R-32 U-0.030 <br /> Door-transparent reach-in triple-pane,heat-reflective treated or gas <br /> Floor R-28 U-0.035 <br /> Coolers-Walk-in and Warehouse <br /> Roof/Ceiling R-25 U-0.039 <br /> Wall R-25 U-0.039 <br /> Door R-25 U-0.039 <br /> Door-transparent reach-in double-pane,heat-reflective treated&gas <br /> fill,or comply with freezer door req. <br /> Floor No Requirement / <br /> v( /., <br />
The URL can be used to link to this page
Your browser does not support the video tag.