My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST DELTA HOTEL 2020-05-04
>
Address Records
>
PINE ST
>
3105
>
DELTA HOTEL
>
3105 PINE ST DELTA HOTEL 2020-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:37:07 AM
Creation date
5/4/2020 11:28:11 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
DELTA HOTEL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Component Performance Path, pg. 2 ENV-UA <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Everett Delta Hotel Date 09/19/2017 <br /> Fenestration Area as%gross above-grade wall area 24.3% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins. R Plan/Detail# F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> 73 12=10 0.540 110 59.4 0.540 110 59.4 <br /> c <br /> a) R= Slab-On-Grade F-0.54 <br /> 2 L <br /> c D R= <br /> O -o R= 0.550 <br /> _0 c <br /> R= I Heated Slab-On-Grade F-0.55 <br /> = R= <br /> Schedule ID U-factor Source9'10 U-factor x Area(A) =UA(U x A) U-factor x Area(A)= UA(U x A) <br /> CD 0.37 <br /> CET) <br /> .ET) Opaque Swing Doors U-0.37 <br /> co (n <br /> O <br /> a 0.34 <br /> .c I Opaque rollup&sliding U-0.34 <br /> O I <br /> To 0.30 <br /> Q) Non-Metal Frame U-0.30 <br /> C <br /> 0 <br /> Z <br /> B,North Side Window Table C303.1.3,Metal with Thermal Break 0.36 I 104 37.4 0.38 ! 448 I 170.3 <br /> x C,East Side Breakfast ITable C303.1.3,Metal with Thermal Break I9. 1 210 75.6 Metal Frame, Fixed U-0.38 <br /> o <br /> 487-da� D,East Side Fitness Table C303.1.3,Metal with Thermal Break 0.36 I 158 56.9 <br /> c <br /> 0.40 <br /> u.. o <br /> Metal Frame,Operable U-0.40 <br /> o m <br /> O 1r, <br /> c 2 <br /> 8 A,West Side Entry Table C303.1.3,Metal with Thermal Break 0.36 ' 99 35.6 0.60 94 56.4 <br /> c <br /> f2 Metal Entrance Door U-0.60 <br /> c <br /> c <br /> 2 <br /> m 0.50 <br /> w c <br /> .c 0. All types U-0.50 <br /> m <br /> T <br /> co Q <br /> Area' UA Area' UA <br /> Target Area Adjusted Page 2 Subtotal 681 265 652 286 <br /> TO COMPLY-The Proposed Total UA shall not Page 1 Subtotal 2483 75 2512 103 <br /> exceed the Target Total UA. Project Total 3164 340 3164 389 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wall U-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls, Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame,or shall be <br /> the default value per Section C303.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.