My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST DELTA HOTEL 2020-05-04
>
Address Records
>
PINE ST
>
3105
>
DELTA HOTEL
>
3105 PINE ST DELTA HOTEL 2020-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:37:07 AM
Creation date
5/4/2020 11:28:11 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
DELTA HOTEL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Everett Delta Hotel Date 09/19/2017 <br /> Fenestration Area as%gross above-grade wall area 24.3% Max.Target: 30% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) SHGC x P SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> Skylight Totals <br /> I All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A).SHGC x A Category SHGC x Area(A)= SHGC x A <br /> A 0 0.33 99 33 PF<0.2 0.40 443 I 177.3 <br /> C 0 0.33 210 69 0.25.PF<0.6 0.48 <br /> D 0 0.33 158 52 PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +If PF credit is applied, then vertical fenestration <br /> Pp Non-North Window Totals 467.0 154.1 443.4 177.3 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch. ID Provide SHGC source and fenestration schedule ID Category <br /> B 0 0.33 ! 104 34 pF<0.2 0.53 99 52.3 <br /> 0.2<-PF<0.5j 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will sum <br /> fenestration area by PF category. <br /> North Window Totals 104.0 34.3 98.7 52.3 <br /> TO COMPLY-The Proposed Total SHGCx A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 571.0 188.4 542.1 229.7 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br />
The URL can be used to link to this page
Your browser does not support the video tag.