My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST DELTA HOTEL 2020-05-04
>
Address Records
>
PINE ST
>
3105
>
DELTA HOTEL
>
3105 PINE ST DELTA HOTEL 2020-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:37:07 AM
Creation date
5/4/2020 11:28:11 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
DELTA HOTEL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans Checklist, pg. 2 ENV-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 <br /> Project Title: Everett Delta Hotel Date 09/19/2017 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> 0103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll-up/sliding) <br /> C402.4:4 Opaque doors on wall sections or in door schedules-applies to doors with less than 50% <br /> glazed area <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> C402.2.5 unconditioned space Indicate framing material on floor sections; <br /> insulation Indicate material density category and weight of qualifying mass floors <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required <br /> C303.2.1 insulation distance from top of slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> 0402.2.6 Radiantly heated slab.detail; <br /> on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> 0303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> C402.4.1 Provide calculation for total vertical fenestration area as a percentage of <br /> C502.2.1 Vertical fenestration gross above grade wall area(WWR)for new construction,additions and <br /> C503.3.2 maximum area alterations In ENV-SUM <br /> Provide calculations showing that the percentage of overall conditioned <br /> floor area within daylight zones is equal to or greater than 50%in 1&2 story <br /> builidngs:OR <br /> Increased Provide calculations showing that the percentage of overall net floor area <br /> C402.4.1.1 prescriptive within daylight zones is equal to or greater than 25%in buildings 3 stories or <br /> C405.2.4.1 maximum vertical more;include the gross floor area and list of spaces omitted for the net floor <br /> C502.2.1 fenestration area with area; <br /> C503.3.2 daylight zones and Note in envelope plans that all lighting fixtures located within daylight zones <br /> controls shall be provided with daylight responsive controls per WSEC Section <br /> C405.2.4.1;indicate method of control in lighting fixture schedules <br /> Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> Increased Indicate high performance U-factors and SHGC values in fenestration <br /> C402.4.1.3 prescriptive schedules; <br /> C502.2.1 maximum vertical If applicable,provide area-weighted U-factor calculation(s)used for multiple <br /> C503.3.2 fenestration area with fenestration elements within the same fenestration category per Table <br /> high-performance C402.3 <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served by <br /> 0402.4.1.4 maximum vertical a dedicated outside air system(DOAS)that delivers ventilation air without <br /> 0403.6 fenestration area with requiring operation of the heating/cooling system per Section C403.6 <br /> DOAS mechanical <br /> systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be used <br /> C402.1.5 fenestration target to account for vertical fenestration area in excess of the prescriptive <br /> area adiustment maximum allowed <br /> C402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof area <br /> 05 <br /> 0502.2.2 area (SRR)for new construction,additions and alterations in ENV-SUM <br /> 0503.3:3 <br /> C402.1.5.2 Roof/skylight target Indicate if component performance with target area adjustment will be used <br /> area adjustment to account for skylight area in excess of the prescriptive maximum allowed <br /> Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC and If applicable,provide area-weighted U-factor calculation(s)used for multiple <br /> C402.4.3 VT for all fenestration fenestration elements within the same fenestration category per Table <br /> C303.1.3 assemblies C402.3 <br /> Indicate if values are NFRC or default;if default then specify frame type, <br /> glazing layers,gap width,low-e coatings,gas-fill <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> C402.4.3 provide projection factor calculations(Equation C4-6)and associated <br /> devices minimum SHGC for north and non-north orientations <br /> (/ /5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.