Laserfiche WebLink
f <br /> Job Truss To_— Qty Ply TBC-12'OC NO CLG LOAD <br /> 111402882 <br /> 88610263 24' FINK 1 1 <br /> Job Reference(optional) <br /> The Truss Co., Burlington,WA,98233 8.020 s Aug 1 2016 MiTek Industries,Inc.Fri Oct 14 16:43:28 2016 Page 1 <br /> ID:iNtt5wZxghjyPSTyDWcrLTyVuEE-7GSPJVTJcJOH?GWFLbITFV gtN66WSIIFLEPksyTRVz <br /> 6-7-15 12-0-0 17-4-1 24-0-0 I <br /> 6-7-15 5-4-1 5-4-1 6-7-15 <br /> Scale=1:38.2 <br /> 5x6 = <br /> V <br /> 4.00 112 <br /> 2x4 ' • 0 410 2x4 <br /> 4' <br /> �7 a <br /> .,,,, <br /> 8\ <br /> - _...-. 2 f <br /> ' cT 51 A , <br /> CL_Y Y Aggie <br /> B2 <br /> 4iiIIIIIto <br /> • <br /> ► 4x10 = 8 7 6 A 4--- <br /> 4x4= 4x6 = 4x4= 4x10 = <br /> I _ 8-5-5 I 15-6-11 - -. 24-0-0 I <br /> 8-5-5 7-1-6 _ 8-5-5 <br /> Plate Offsets(X,Y)— f1:0-2-15,0-2-01,(5:0-2-15 0-2-01 _ <br /> LOADING (psf) SPACING- 6-0-0 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.60 Vert(LL) -0.22 6-8 >999 240 MT20 220/195 <br /> (Roof Snow=25.0) Lumber DOL 1.15 BC 0.67 Vert(CT) -0.27 6-8 >999 180 <br /> TCDL 5.0 Rep Stress Incr NO WB 0.45 Horz(CT) 0.08 5 n/a n/a <br /> BCLL 0.0 * Code IBC2015/TPI2014 Matrix-S Weight:126 lb FT=10% <br /> BCDL 1.0 <br /> LUMBER- BRACING- <br /> TOP CHORD 2x6 DF SS TOP CHORD 2-0-0 oc purlins(3-0-9 max.). <br /> BOT CHORD 2x6 DF SS BOT CHORD 6-9-0 oc bracing:1-5 <br /> WEBS 2x4 DF Stud <br /> NOTE:IF ACTUAL SPACING OF THE TRUSS IS 2-TRUSSES <br /> REACTIONS. (lb/size) 1=2189/0-5-8 (min.0-2-5),5=2189/0-5-8 (min.0-2-5) 12-0"O.C.(ONE EACH SIDE OF POST)THE SPACING <br /> Max Horz 1=-91(LC 8) OF THE BOTTOM CHORD LATERAL BRACING MAY BE <br /> Max Uplift 1=-749(LC 10),5=-749(LC 10) INCREASED TO 12-0"O.C.PROVIDED CONTINUOUS <br /> 2X6 BLOCKING IS USED ALONG THE FULL LENGTH OF <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. THE BOTTOM CHORD(SEE SECTION A-A). CONNECT <br /> TOP CHORD 1-2=5220/1771,2-9=-4414/1584,3-9=-4243/1612,3-10=-4243/1612,4-10=-4414/1584, BLOCKING WITH 10D NAILS AT 6"oc ALONG EACH B.C. <br /> 4-5=-5220/1771 <br /> BOT CHORD 1-8=-1568/4768,7-8=-943/3239,6-7=-943/3239,5-6=-1568/4768 CONT.2X6 <br /> WEBS 2-8=-1292/487,3-8=-453/1354,3-6=-453/1354,4-6=-1292/487 BLOCKING <br /> L�I�vP.rod <br /> NOTES- F I rNAIL <br /> 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=3.Opsf;BCDL=0.6psf;h=25ft;B=45ft;L=24ft;eave=4ft;Cat.II; <br /> Exp B;partially;MWFRS(directional);cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 plate 2X B.C. <br /> grip DOL=1.60 <br /> 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 SECTION A-A <br /> 3) Unbalanced snow loads have been considered for this design. <br /> 4)The bottom chord dead load shown is sufficient only to cover the truss weight itself and does not allow for any additional load to be <br /> added to the bottom chord. <br /> 5) Dead loads shown include weight of truss. Top chord dead load of 5.0 psf(or less)is not adequate for a shingle roof. Architect to <br /> verify adequacy of top chord dead load. <br /> 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ° >t r • <br /> 7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will :y, L. po <br /> fit between the bottom chord and any other members. tYrt if" <br /> 8) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 749 lb uplift at joint 1 and 749 lb uplift at 4 /,1, <br /> joint �i/ <br /> 9)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/IP!1. 'c�'+r Agb, i S;` ty <br /> vii ('.�'` iii <br /> LOAD CASE(S) Standard iv <br /> f . r <br /> .,,CS '''' ..e. <br /> 19969 " <br /> October 17,2016 <br /> ® WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE NI11-7473 BEFORE USE. t <br /> Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. <br /> ---------Th2 <br /> Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown yy"" <br /> is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the <br /> erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding <br /> fabrication,quality control,storage,delivery,erection and bracing,consult ANsIiTPll Quality Criteria,DSB-89 and BCSit Building Component 7�f,g{ rt <br /> USS <br /> Safety Information available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719. theTRCO.INC. <br />