My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4220 COLBY AVE B 2020-05-05
>
Address Records
>
COLBY AVE
>
4220
>
4220 COLBY AVE B 2020-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:00:11 AM
Creation date
5/5/2020 8:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4220
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering&Public Services <br /> Department. Electrical inspections and approval are required prior to calling for acceptance tests. Call <br /> (425) 257-8810 for permit information. <br /> The absence of monitoring for the alarm system will be cause for postponing Fire Department inspection <br /> and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy(NFPA 72, <br /> 2010 Edition, Chapter 10,page 114). <br /> Call for design requirements per Authority Having Jurisdiction. <br /> Automatic smoke detection is required. <br /> NOTE: Heat detection required in attic space. <br /> 10. For buildings with two or more floors, including sub-floors,the alarm system must call point-by-point <br /> reporting to an alarm center. <br /> 11. Carbon monoxide alarms must be installed in all new residential construction in R-1,R-2,and R-3 <br /> occupancies per 2012 IFC, Section 908.7(WA State Amendment). <br /> 12. Fire Suppression(Sprinkler) System-An approved automatic suppression system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. The system <br /> must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering&Public Services Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will supply the <br /> sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA 13, <br /> NFPA 13R, or NFPA 13D system.depending upon several factors. Sprinkler installation shall not begin <br /> without an approved and stamped set of plans from the Engineering&Public Services Department. The <br /> Fire Department will also review the plans and shall field inspect the installation based only on approved <br /> plans that must be on site. Changes to plans must be approved by both the Engineering&Public <br /> Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for <br /> private fire mains. (Below-ground piping must be installed by Washington State Patrol Licensed <br /> Underground Sprinkler line certified "U" installers. For further information,contact the State Fire <br /> Marshal's Office at(360) 596-3900 or contact the Everett Fire Department at(425)257-8124.) All such <br /> tests shall be witnessed by a Fire Department inspector. Call (425)257-8124 or(425)257-8120 to make <br /> an appointment for inspection. <br /> SEPA16-023 <br /> rage 6781 <br />
The URL can be used to link to this page
Your browser does not support the video tag.