My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4220 COLBY AVE B 2020-05-05
>
Address Records
>
COLBY AVE
>
4220
>
4220 COLBY AVE B 2020-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:00:11 AM
Creation date
5/5/2020 8:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4220
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
24. Please verify and provide calculations indicating that SW2 wood shearwalls along Grids <br /> C & D on plan sheets do not require drag struts to collect load from both sides of the <br /> diaphragm and into the shear walls. <br /> 25. Please provide diaphragm computations that justify the diaphragm design indicated by <br /> the sheathing in the General Structural Notes. Also, provide chord checks for the <br /> diaphragms. <br /> 26. Please clarify how detail 11/S602 is detailed as it appears that footing F3.0 is sitting <br /> below the footing cut by detail 2/S602. Also, it appears that on plan sheet S100, the <br /> detail 11/S602 appears as one footing. Please clarify the detail and or plans if detail <br /> F3.0 is required. <br /> 27. Please specify where wood shearwalls SW3 and SW4 occur on the building as shown on <br /> Shearwall Schedule on S501. <br /> 28. It appears that new roof over framing is being added to the existing building's roof <br /> framing. Please verify that the existing roof framing is able to resist the additional <br /> loading or provide additional strengthening of the existing roof and their connections <br /> per the IBC 2015. Please provide calculations verifying these new conditions on the <br /> existing roof framing. <br /> 29. It appears that the new structure is being constructed adjacent to an existing structure. <br /> Per ASCE 7-10 Sec 12.12.3, please provide the structural seismic minimum distance and <br /> provide calculations as required. <br /> If you have any questions, please email or call me at (425) 257-7287. Upon submittal of the <br /> drawings, your application will be given priority and plan reviews will recommence. All required <br /> submittals shall be sufficient detail and contain sufficient information to ensure that the proposed <br /> structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> V--"g <br /> Ja s Bronder, PE <br /> Associate Engineer <br /> Plans Examiner <br /> Tony Lee <br /> Building Official <br /> Page 4 of 4_ <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />