Laserfiche WebLink
Phil Haberman Title . ...New... Page: <br /> Geotechnical/Geologic Consultant Job# : ...New... Dsgnr: Date: APR 11,2018 <br /> MSE Wall Design Description.... <br /> Retain Pro 9©1989-2011 Ver:9.27 8171 <br /> RP9.27 Segmental Retaining Wall Design with Geogrids Code: NCMA <br /> Summary:Resisting!Overturning <br /> ti <br /> Resisting Moments <br /> Item Force,lbs Distance,ft Moment,ft-lbs <br /> Wall 320 0.50 160 <br /> Reinf.earth 1,325 2.33 3,081 <br /> Sloped 0 2.78 0 <br /> Dead load 0 2.33 0 <br /> Live load 0 2.33 0 <br /> Total 1,645 3,241 <br /> Overturning Moments <br /> Item Force,lbs Distance,ft Moment,ft-lbs <br /> Earth 195 1.33 260 <br /> Surcharge,DL 0 2.00 0 <br /> Surcharge,LL 0 2.00 0 <br /> Seismic,Wall 48 2.00 96 <br /> Seismic,Reinf. 75 2.00 150 <br /> Seismic,Sloped soil 0 4.00 0 <br /> Seismic,Exterior 48 2.40 114 <br /> Total 366 620 <br /> Overturning Ratio 5.22 <br /> ASSUMPTIONS AND CRITERIA USED <br /> 1. References used include Design Manual for Segmental Retaining Walls,2.1 Edition,and Segmental Retaining Walls-Seismic Design Manual, Edition,both by <br /> NCMA. <br /> 2. Blocks are all same size and uniform offsets(batter)for full wall height. <br /> 3. Coulomb earth pressure theory used for earth pressures and failure plane angle. <br /> 4. Refer to geotechnical report for backfill material,compaction,and other design data and recommendations. <br /> 5. Cap blocks if used are above the retained height and are neglected in this design. <br /> 6. Geogrid LTDS and connection values for block vendors obtained from ICC Evaluation Service(ES Legacy Reports)or as provided by vendors.Since these may <br /> change or be updated,verification of values is recommended. <br /> 7. Block sizes obtained from vendors'literature and may vary with locality. <br /> 8. Geogrid layers are equally spaced vertically,all same length,and laid horizontally. <br /> 9. Average weight of block and cell infill assumed to be 120 pcf. <br /> 10. See vendor web sites(on input screen)for more information and specifications. <br /> 11. Design height is limited to 16 feet or 24 blocks,whichever is less. Contact vendor for higher designs or special conditions. <br /> 12. Seismic design is per Seismic Design Manual cited above. Also see Methodology/Seismic Design in User's Manual. <br /> 13. Vendor specifications or project specifications,whichever is most restrictive,to be followed for construction procedures. <br /> 14. Add notes and details for proper drainage. <br /> 15. See User's Manual Design Example#10 for methodology and sample verification calculations. <br /> 16. Final design responsibility is with the project Engineer-of-Record. <br /> • <br /> /i <br />