Search
3631 WETMORE AVE 2020-05-06
>
Address Records
>
WETMORE AVE
>
3631
>
3631 WETMORE AVE 2020-05-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:38:04 PM
Creation date
5/6/2020 1:37:41 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3631
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Phil Haberman Title . ...New... Page: <br /> GeotechnicallGeologic Consultant Job# : ...New... Dsgnr: Date: APR 11,2018 <br /> MSE Wall Design Description.... <br /> Retain Pro 9©1989-2011 Ver:9.27 8171 <br /> RP9.27 Segmental Retaining Wall Design with Geogrids Code:NCMA <br /> Summary:Resisting/Overturning <br /> Resisting Moments <br /> Item Force,lbs Distance,ft Moment,ft-lbs <br /> Wall 480 0.50 240 <br /> Reinf.earth 3,113 3.08 9,571 <br /> Sloped 0 3.78 0 <br /> Dead load 0 3.08 0 <br /> Live load 0 3.08 0 <br /> Total 3,593 9,811 <br /> Overturning Moments <br /> Item Force,lbs Distance,ft Moment,ft-lbs <br /> Earth 439 2.00 878 <br /> Surcharge,DL 0 3.00 0 <br /> Surcharge,LL 0 3.00 0 <br /> Seismic,Wall 72 3.00 216 <br /> Seismic,Reinf. 225 3.00 675 <br /> Seismic,Sloped soil 0 6.00 0 <br /> Seismic,Exterior 107 3.60 385 <br /> Total 843 2,155 <br /> Overturning Ratio 4.55 <br /> ASSUMPTIONS AND CRITERIA USED <br /> 1. References used include Design Manual for Segmental Retaining Walls,2.1 Edition,and Segmental Retaining Walls-Seismic Design Manual, 1st Edition,both by <br /> NCMA. <br /> 2. Blocks are all same size and uniform offsets(batter)for full wall height. <br /> 3. Coulomb earth pressure theory used for earth pressures and failure plane angle. <br /> 4. Refer to geotechnical report for backfill material,compaction,and other design data and recommendations. <br /> 5. Cap blocks if used are above the retained height and are neglected in this design. <br /> 6. Geogrid LTDS and connection values for block vendors obtained from ICC Evaluation Service(ES Legacy Reports)or as provided by vendors.Since these may <br /> change or be updated,verification of values is recommended. <br /> 7. Block sizes obtained from vendors'literature and may vary with locality. <br /> 8. Geogrid layers are equally spaced vertically,all same length,and laid horizontally. <br /> 9. Average weight of block and cell infill assumed to be 120 pcf. <br /> 10. See vendor web sites(on input screen)for more information and specifications. <br /> 11. Design height is limited to 16 feet or 24 blocks,whichever is less. Contact vendor for higher designs or special conditions. <br /> 12. Seismic design is per Seismic Design Manual cited above. Also see Methodology/Seismic Design in User's Manual. <br /> 13. Vendor specifications or project specifications,whichever is most restrictive,to be followed for construction procedures. <br /> 14. Add notes and details for proper drainage. <br /> 15. See User's Manual Design Example#10 for methodology and sample verification calculations. <br /> 16. Final design responsibility is with the project Engineer-of-Record. <br /> ( 1, <br />
The URL can be used to link to this page
Your browser does not support the video tag.