• <br /> From:Sean McKenna <seanm@evha.org> <br /> Sent:Wednesday, November 14, 2018 8:28 AM <br /> To: Drew Martin <dmartin@everettwa.gov> <br /> Cc: Randy Heltne<randyh@evha.org>; Rick Dorris<rickd@evha.org>; charliesr@cmaarch.com <br /> Subject:Wiggums Office Addition Permit Application: B1807-032R <br /> Hi Drew, <br /> Randy and I are in possession of your follow-up notes.We ask that you issue our permit and allow us to proceed with this <br /> time-sensitive project in service to our low-income households.We will address each item below to your satisfaction; <br /> our team will work on this today. <br /> Architectural <br /> 5b. The minimum insulation shall be R-9.5 continuous or R-21.Agreed. Will note on plans. <br /> 16. The following should be specified in the drawings: <br /> a.Specify demolition required to convert Main Floor restrooms to single-user restrooms. Work includes, but is <br /> not limited to:compartment walls,stud partition walls(i.e., inside men's room, outside women's room),second toilet in <br /> women's room„ Remove partitions,one sink, one toilet. Install new ADA fixtures. Install interior door lock. Men's room is <br /> not single-user, but will have interior door lock. <br /> b. Provide interior locks for doors. <br /> 22.Specify maximum 1:20 slope for sidewalk on east side of the building.Agreed. Will note on plans. <br /> 32. This comment has not been addressed. Structural drawings have been added to the construction drawing set that <br /> were not included in the original submittal. The architectural drawings include structural information that duplicates or <br /> differs from information provided in the structural drawings. A note shall be provided on Sheet A-0 stating: "The <br /> architectural drawings include structural information that is duplicated by the structural drawings. Where discrepancies <br /> occur, the structural drawings shall control the structural work to be performed.” See IBC Section 107.2.1.Agreed. Will <br /> note on plans. <br /> Structural <br /> 13. Sheet A-7 still shows both new 2x8 framing and trusses. Confirm the former should be removed from the plan. We <br /> will remove 2x8 framing in lieu of Manufactured Engineered Trusses. <br /> 26a.Sheet A-6 still shows the detail. Confirm detail should be removed. We will delete detail. <br /> 29. The design,for the holdown concrete anchors has not been performed per code. The design loads are the Simpson <br /> holdown allowable capacities divided by the seismic ASD multiplier of 0.7;see calculation page 17. This is not valid. The <br /> design loads shall be determined using the overstrength factor and load combinations as specified in the original <br /> comment. Based on the loads on page 16, the maximum design load is at least 15 kips;the LRFD design load shall be <br /> substantiated(i.e., the design shall not be performed using the 15 kips stated in this comment). Alternatively, the <br /> holdown anchor may be designed using the tested ultimate strength (i.e.,failure capacity)of the holdowns as <br /> determined by the manufacturer. This alternative approach satisfies ACI 318-14 Section 17.2.3.4.3 Option <br /> (b)/(c). Documentation from the manufacturer establishing the ultimate strength shall be submitted; a soft-converstion <br /> of the allowable capacity it not valid. Supplemental calculations substantiating the anchor design shall be submitted for <br /> review.Our Engineer is addressing the hold down anchor design. <br />