oo ELECTRtCAL PLAN REVIEW <br /> DIRECTIONS:Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-468-900. If plan review is <br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> With this permit application. <br /> *• If item(a)-(ii,iii,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> 71 (a)Electrical plan review is not required for: <br /> El (i)Low voltage systems; <br /> 4--[ ] (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project <br /> El (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> • <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system • <br /> does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits riot exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F), <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2: <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total <br /> rating of 9600 watts or less. <br /> • (vii)For installations in(a)(ii),(iii),and(v)of this subsection to be considered,the following must be available <br /> to the eiectrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed;and <br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> Li physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> -- (b)Electrical plan review is required for all other new or altered electrical projects in educational,institutional, or health care <br /> occupancies defined in this chapter. <br /> fl (c)If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 904,1 Table 900-2 <br /> Health or Personal Care FarattieT <br /> Educational and Institutional Facilities,Places of Assembly,or Other Facilities <br /> Health or Personal Care FacilityPlan Review <br /> Type Require/I Educational,institutional,or Plan Review <br /> Other Facility Types Required <br /> rioso.ta <br /> retesting come Levi of tang-cern- esEchileatioria, VS5 <br /> art to* ostdutooal Yes <br /> Boaridtrif home <br /> AntWeett Mftmg fac; <br /> Priveteokohisrsm Icsoria Notes to Tables 900-1 and 000-2. <br /> IPOratemcistarr/c noypeal c,A.city authorized to do e ectnitai inspections <br /> Maternity home yes may requ re p'an review on faciity types not <br /> A,nbsdaeory vinery 4achey Vt5 reviewed by the depaqnrient <br /> Rene bernocita'yss c <br /> ReMat.glOda treinme.rg faCt',:y. Yes <br /> Enhanced senesce f,Kgrty Yet <br /> ACatt res4Sentw rehabErrarioc, Yea <br /> PERMIT# Page 2-Plan Review <br /> tereit, <br />