Laserfiche WebLink
7/18/2019 City of Everett Page 1/3 <br /> 2:22:03PM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. C1811-005 Site Address 314 OLYMPIC BLVD <br /> Applied 11/16/2018 Applicant Lot <br /> Approved 11/16/2018 Owner STUMPF MARK A/ELIZABETH M Block <br /> Issued 11/16/2018 Contractor ABODE CONTRACTING INC Tract <br /> Parent Permit No. Description ADD LAUNDRY AND BATHROOM USING EXISTING GARAG <br /> Notes **NEEDS SEPARATE ELECTRICAL PERMIT** <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> 2/13/2019 2/13/2019 PLUMB DXW NO ACCESS Call for access <br /> 03-ROUGH IN Phone:425-319-8217 <br /> 2/15/2019 2/15/2019 PLUMB SDP NO ACCESS Next Door.CALL Call for access <br /> 03-ROUGH IN FOR ACCESS Phone:425-319-8217 <br /> (2/15/2019 1:34 PM SDP) <br /> The inspector called the number given,got <br /> voicemail and left a message to call her <br /> back on her cell phone. The inspector cell <br /> phones come in as blocked,please answer. <br /> 2/20/2019 2/20/2019 PLUMB SDP CORRECTION #2222/see notes Call for access <br /> 03-ROUGH IN Phone:425-319-8217 <br /> (2/20/2019 2:51 PM SDP) <br /> Waste and vents are not plumbed to code. <br /> The inspector left some drawings to help. <br /> The inspector will need access to the crawl <br /> space and the attic to complete the <br /> inspection. Will need permission to enter <br /> the house. <br /> 2/26/2019 2/26/2019 PLUMB SDP CORRECTION see notes Garage code#2222 <br /> 03-ROUGH IN Pull down ladder for attic <br /> Crawl space located down hall to right in <br /> closet <br /> Phone:425-319-8217 <br /> (2/26/2019 12:24 PM SDP) <br /> 1)Short turn 90's are only allowed on vents <br /> above the flood rim of a fixture.When <br /> draining from vertical to horizontal you <br /> need to use drainage fittings that are equal <br /> to the sweep of a 45 degree.The 90 degree <br /> fitting at the floor level of the washer <br /> drainage is too short. <br /> 2)The bathroom vent must remain 2" <br /> through the roof,you cannot reduce the <br /> size. <br /> 3)The 2"drainage line in the crawl <br /> connected to the washer,lay and shower is <br /> badly backgraded with no hangers or <br /> supports. <br /> These are the main problems with the <br /> drainage plumbing.Please contact Shellie. <br /> 425-257-7274 or cell phone 425-508-8659. <br /> 3/5/2019 3/5/2019 PLUMB SDP APPROVAL See notes 2222 Garage Code <br /> 03-ROUGH IN 425-319-8217 Mark <br /> (3/5/2019 2:55 PM SDP) <br /> The 2"line in the crawl still looks <br /> backgraded.Please address this before <br /> final.Any questions call Shellie. <br /> INSP12 CIMOVS YS TEA4 <br />