Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R Revised Nov2017 <br /> Project Title: Lakehouse Clubhouse Rennovation Date 6/29/2020 <br /> Calculation 0 New Construction Addition- r,Addition For Building Department Use <br /> Area NOTESw stand alone w +existing <br /> 0 Spaces where <50%of Spaces where z 50%of in Spaces where the Use <br /> luminaires are replaced luminaires are replaced is changing (C505) <br /> LPA 0 Standard is Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3, the Proposed LPD shall be 25%lower than the Target LPA. User <br /> Type Refer to C406.3 for additional requirements. Note <br /> Maximum Allowed Lighting Wattagt TE , <br /> Watts Allowed <br /> Location(plan#, Gross Interior Allowed <br /> (watts/ft2 x area) <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 NOTE 2 <br /> Office ALL except Rm#3 Leasing Offices&Lounge for Residential 2077 0.66 1371 <br /> Community <br /> Exercise Center Rm#3 Fitness Center for Community 1168 0.67 783 <br /> Total 3245 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 3,4,5,6 Fixtures Fixture NOTE 7 Watts Proposed <br /> Office ALL Except Rm#2 Ceiling Recessed LED Can Light(New&Existing) 24 15 360 <br /> Office ALL except Rm#2 Sconce-LED(New) 3 9 26 <br /> Office ALL except Rm#2 Custom Fabricated LED Pendant(Existing) 3 36 108 <br /> Office ALL except Rm#2 Chandelier-LED(Existing) 1 10 10 <br /> Office ALL except Rm#2 Trough Light(Existing) 2 50 100 <br /> Exercise Center RM#2 Custom Fabricated LED Pendant 16 36 576 <br /> Compliance by Building AreaNOTEe <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Confirm all fixtures are reported under proposed lighting-low watts COMPLIES <br /> Office 1371 604 <br /> relative to maximum allowed. C406.3 <br /> COMPLIES <br /> Exercise Center 783 576 C406.3 <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 2154 1180 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Unlit Message-Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting <br /> Power Allowance. <br /> Note 3-Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8), numberof lamps in the fixture,and ballast type(if <br /> included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture, lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as <br /> existing in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. <br /> For <br /> luminaires with screw-in lames enter the manufacturer's listed maximum.innu ttaae of the fixture(not the lamn wattaae)_ For low <br />