4/20/2021 Page <br /> City of Everett <br /> 9:05:33AM <br /> �- INSPECTION ACTIVITY REPORT <br /> Permit No. E2102-015 Site Address 12115 19TH AVE SE CLUBHOUSE <br /> Applied 2/1/2021 Applicant RHEMA ELECTRIC LLC Lot <br /> Approved 2/2/2021 Owner AUK-SILVERLAKE LLC Block <br /> Issued 2/2/2021 Contractor RHEMA ELECTRIC LLC Tract <br /> Parent Permit No. B2008-011 Description ALTER CIRCUITS FOR CLUBHOUSE REMODEL <br /> Notes Clubhouse remodel <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> 2/4/2021 2/4/2021 ELEC 06-ROUGH TJJO PARTIAL APPR eTRAKiT Inspection 2/2/2021 2:42 PM RHEMA ELECTRIC <br /> IN Request LLC <br /> Mark(360)770-8115 <br /> AM inspection preferred <br /> Contact Name:RHEMA ELECTRIC LLC <br /> Site Address: 12115 19TH AVE SE <br /> CLUBHOUSE <br /> Phone:3604168227 <br /> e-Mail:mark@rhemaelectric.com <br /> (2/4/2021 4:29 PM TJJO) <br /> L&i had been inspecting job on permit <br /> 3497017E.Met with contractor and walked <br /> what had already been inspected.Recessed <br /> cans in exit and sloped ceilings and wall <br /> recepticals in existing approved. <br /> Verify ground screws on o/s receptacles on <br /> maint.Office rough in. <br /> 2/9/2021 2/9/2021 ELEC 06-ROUGH TJJO CORRECTION eTRAKiT Inspection 2/5/2021 3:10 PM RHEMA ELECTRIC <br /> IN Request LLC <br /> PM Inspection Preferred <br /> Contact Name:RHEMA ELECTRIC LLC <br /> Site Address: 12115 19TH AVE SE <br /> CLUBHOUSE <br /> Phone:3604168227 <br /> e-Mail:mark@rhemaelectric.com <br /> (2/9/2021 4:04 PM TJJO) <br /> Flexible metal conduit needs to be properly <br /> secured.Grounding pigtails needed in the <br /> two boxes on o/s wall of maintenance office <br /> 2/17/2021 2/17/2021 ELEC 06-ROUGH TJJO PARTIAL APPR eTRAKiT Inspection 2/16/2021 12:28 PM RHEMA ELECTRIC <br /> IN Request LLC <br /> Contact Name:Donovan Rosling <br /> Site Address: 12115 19TH AVE SE <br /> CLUBHOUSE <br /> Phone:4252449628 <br /> e-Mail:donovan@rhemaelectric.com <br /> (2/17/2021 3:54 PM TJJO) <br /> Corrections approved <br /> 3/12/2021 3/12/2021 ELEC 02-GROUND MCB APPROVAL eTRAKiT Inspection 3/11/2021 2:25 PM RHEMA ELECTRIC <br /> WORK Request LLC <br /> Contact Name:RHEMA ELECTRIC LLC <br /> Site Address: 12115 19TH AVE SE <br /> CLUBHOUSE <br /> Phone:3604168227 <br /> e-Mail:katrina@rhemaelectric.com <br /> INSP12 <br />