Laserfiche WebLink
Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 states and all R1 Revised Jan 2014 <br /> Project Address Fred Meyer/Kroger#458 Date 7/10/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and transformer requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> Provide fixture schedule with fixture types,lamps,ballasts,and Lightng Plan E1.1 <br /> rated watts per fixture; <br /> C405.5.1 Identify spaces eligible for lighting power exemption on plans <br /> C405.5,1,1 Total connected and in compliance forms; <br /> Yes C405,5.12 <br /> C405.5,1,3 interior lighting power Identify lighting equipment eligible for exemption in fixture <br /> C405,5.1,4 schedule and in compliance forms; <br /> Indicate that exempt lighting equipment is in addition to general <br /> area lighting and is controlled independently <br /> Yes C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture Lightng Plan E1.1 <br /> schedule(maximum 5 watts per fixture) <br /> C405.10 Cooler and freezer For lighting in walk-in coolers and freezers,and refrigerated <br /> NA C405.11 lighting warehouse coolers and freezers,provide rated lamp efficacy(in <br /> lumens per watt)in fixture schedule <br /> Lighting Power Calculation-Indicate compliance path taken <br /> Complete required compliance forms—proposed wattage per <br /> NA C405.5.2 Building Area Method building area does not exceed maximum allowed wattage per <br /> building area.Identify locations of building areas on plans <br /> Complete required compliance forms—total proposed wattage <br /> Yea C405.5.2 Space-By-Space does not exceed maximum allowed wattage.Identify locations Lightng Plan E1.1 <br /> Method of space types on plans,including retail display areas as <br /> applicable <br /> EXTERIOR LIGHTING POWER&EFFICACY(Section C405.6) <br /> Provide fixture schedule with fixture types,lamps,ballasts,and Lightng Plan E1.1 <br /> Total connected rated watts per fixture; <br /> Yes C405,6.2 exterior lighting Identify exterior applications eligible for lighting power <br /> power exemption on plans and in compliance forms; <br /> Indicate that exempt exterior lighting is controlled independently <br /> from non-exempt exterior lighting <br /> NA Table Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ <br /> C405.6.2(1) <br /> Exterior building For building grounds fixtures rated at greater than 100 watts, <br /> NA C405.6.1 grounds lighting provide rated lamp efficacy(in lumens per watt)in fixture <br /> schedule <br /> Exterior lighting Complete required compliance form—proposed wattage for <br /> NA C405.6.2 exterior lighting plus base site allowed does not exceed <br /> power calculations maximum allowed <br /> MOTORS&TRANSFORMERS(Sections C405.8,C405.9) <br /> NA C405.8 Electric Motors For motors not part of an HVAC system,provide electric motor <br /> schedule on electrical plans with hp,rpm,and rated efficiency <br /> NA C405,9 Transformers Provide distribution transformer schedule on electrical plans <br /> with transformer size and efficiency <br /> If"no"is selected for any question,provide explanation: <br /> C4O5.2.2.1 Lighting controlled by occupancy sensors. <br />