• <br /> DIAPHRAGM AND SHEARWALL SCHEDULE STRUCTURAL NOTES <br /> HEM-FIR FRAMING DESIGN CRITERIA <br /> JET <br /> . <br /> • 2015 BC <br /> TYPE SHEATHING STUD EDGE FIELD PLATE BLOCK 3x STUDS AT A35/LTP4 CAPACITY • WIND 110 MPH ULT,EXPOSURE B <br /> (4) SPACING NAILING NAILING NAILING EDGES PANEL EDGES SPACING PLF • SEISMIC DESIGN CATEGORY D,SITE CLASS D <br /> • FLOOR LIVE LOAD =40 PSF Jarnot Engineering,Inc. <br /> FLOOR 3/4' APA 10d 6 6' 10d 9 12' N/A NO N/A 185 /260 • ROOF SNOW LOAD=25 PSF P.O.Box 704 <br /> ROOF 1/16" APA 8d 6 6' ed 6 12' N/A NO N/A 145 /205 <br /> GENERAL Monroe,WA 98272 <br /> Ph.(360)863-1831 <br /> NOTES L CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING PRIOR TO Fax(360)863.1481 <br /> 2. NAILS SHALL BE COMMON OR HOT DIPPED GALVANIZED BOX.STAGGER NAILING AT PLYWOOD JOINTS AND SILL PLATES. COMPLETION OF ALL STRUCTURAL ELEMENTS. <br /> 2. ANCHOR BOLTS SHALL BE 1/2'DIAMETER AT SPACINGS MARKED ON FOUNDATION PLAN MARKED AS THUS:0 2. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS,ELEVATIONS AND <br /> DIMENSIONS BEFORE COMMENCING WORK THE ENGINEER SHALL BE NOTIFIED <br /> 3. PLACE ANCHOR BOLTS WITHIN 12'OF END BUT NOT LESS THAN 1 BOLT DIAMETERS.USE 3'x3'x229'GALVANIZED PLATE WASHER IMMEDIATELY UPON DISCOVERY OF ANY DISCREPENCIES. <br /> 4. 3/8'OR 15/32'APA RATED SHEATHING MAY BE SUBSTITUTED FOR 1/16'SHEATHING FOR WALLS ONLY. CONCRETE <br /> 5. HOLDOWNS REQUIRE DOUBLE STUD U.ON. I. f'c=2500 PSI AT 28-DAYS,5 SACKS OF CEMENT PER YARD MINIMUM,5'MAXIMUM <br /> SLUMP. <br /> ROOF SHEATHING 2. REINFORCING STEEL ASTM A-615,GRADE 40 UNLESS OTHERWISE NOTED.DETAIL, <br /> 8d a 6'oc U.ON. FABRICATE AND PLACE IN ACCORDANCE WITH THE LATEST EDITION OF A.G.I.'MANUAL <br /> OF STANDARD PRACTICE'. <br /> VENT BLOCKS ROOF SHEATHING <br /> N <br /> 3. CONCRETE COVER ON REINFORCING STEEL.(CLEAR DIMENSIONS)± <br /> Sd a 6'oc U.ON. FORMED SU�ACES EXPOSED TO EARTH OR WEATHER=2' <br /> = ____ � CAST AGAINST SOIL =3' <br /> 1/ 4. LAP ALL FIELD SPLICES 32 BAR DIAMETERS,16'MINIMUM,UNLESS OTHERWISE NOTED. REVISION BY <br /> PROVIDE CORNER BARS AT ALL CORERS OR WALL INTERSECTIONS. <br /> SIMPSON H-IEDGE NAILING PER <br /> e 24'oc ;\\___ SHEARWALL SCHEDULE /' 5. PROVIDE•4 BARS IN FOUNDATION WALLS AT 18'oz.HORIZONTAL AND VERTICAL <br /> ' GABLE UNLESS OTHERWISE NOTED.PLACE THE TOP HORIZONTAL BAR ABOVE THE HOOK OF <br /> SHEARWALL END TRUSS THE ANCHOR BOLTWITH 24S.WHERE FOUNDATION VENTS INTERRUPT THE TOP BAR ADD(I)•4 <br /> PER PLAN GABLE END UNDER THE VENT 'LAP EACH SIDE. <br /> i <br /> A35 PER SHEARUJALL 6, REINFORCE AROUND WALL AND SLAB OPENINGS WITH ONE EXTRA 5 x 4'-0'LONG <br /> TABLE IF SHEATHING 16d PLATE NAILING DIAGONAL BAR AT EACH CORER <br /> NOT LAPPED ON RIM PER SHEARWALL TABLE <br /> JOIST OR COMMON IF SHEATHING NOT A35 a 32'oc <br /> PLATEII <br /> LAPPED ON RIM JOIST <br /> 1. 1/2'DIAMETER ANCHOR BOLTS PER PLAN,48'o.c.MAXIMUM SPACING WITH 1' <br /> OR COMMON PLATE \ I6'd TN a 12'oc EMBEDMENT,UNLESS OTHERWISE NOTED. I-1 <br /> M.11; <br /> 5. ALL REINFORCING BARS,ANCHOR BOLTS,HONDOWNS AND OTHER CONCRETE 1-4►__ INSERTS SHALL BE SECURED IN POSITION PRIOR TO PLACING CONCRETE. <br /> Z1•:.- EDGEPERSHEARWNAILING ALL 9. EPDXY ADHESIVE SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.DUST 0 ` <br /> AND DEBRIS SHALL BE REMOVED FROM HOLES DRILLED IN CONCRETE.HOLDOWN W <br /> SCHEDULE n <br /> ANCHOR BOLTS SHEARWALL ANCHORS SHALL NOT BE TIGHTENED UNTIL EPDXY HAS CURED. F� <br /> PER PLAN PER PLAN F"� <br /> WOODH <br /> r,S <br /> SHEAR TRANSFER DETAIL 1. ALL SOLID LUMBER TO BE DOUG-FIR NO.2 OR BETTER UNLESS OTHERWISE NOTED. w <br /> LUMBER IN CONTACT WITH CONCRETE OR EXPOSED TO WEATHER WAHLL BE <br /> PRESSURE TREATED. <br /> 2. PROVIDE CUT WASHERS FOR ALL BOLTS BEARING ON WOOD. U H <br /> Sd e 3'oc EW 3. ALL NAILS SHALL BE COMMON WIRE NAILS,UNLESS EXPOSED TO THE WEATHER,THEN Z <br /> HEADER PER PLAN 0 <br /> USE BOX NAILS HOT DIPPED GALVANIZED. <br /> 4. NAILING MINIMUM SHALL COMPLY WITH IBC TABLE 2304.5.1 UNLESS OTHERWISE NOTED. W .c <br /> 111111 <br /> WN 5. METAL CONNECTORS PER SIMPSON STRONG-TIE COMPANY,INC.INSTALL PER <br /> MANUFACTURER'S RECOMMENDATIONS AND AS NOTED ON PLANS. ` i/ <br /> W <br /> (2)ROWS 16d I1 6. CLU-LAMINATED LUMBER SHALL 8E 24F-V4(OR V3)FOR SINGLE SPAN BEAMS. <br /> SINKERS a 3'oc MULTI-SPAN BEAMS SHALL BE 24F-V8,UNLESS OTHERWISE NOTED. P4om. H <br /> SIMPSON 6224.ALSO USE OTHER <br /> SIDE IF END STUD NOT FULL 1. MANUFACTURED FLOOR SYSTEMS SHALL BE INSTALLED PER THE MANUFACTURERS <br /> BREAK SHEATHING WITHIN HEIGHT STANDARDS AND DETAILS. �t; .J <br /> 24'OF MID-HEIGHT(IF F-�-1 FLI <br /> NECESSARY).USE 3x 1/16'APA RATED SHEATHING FULL ,� <br /> BLK'G OR(2)2x NAILED , HEIGHT FROM SILL PL TO TOP OF 8. FASTENERS FOR PRESSURE PRESERVATIVE AND FIRE-RETARDANT TREATED WOOD H > P4 <br /> d <br /> TOGETHER W/16de 3'oc L—•' HDR W/8c103'oc ALL STUDS AND SHALL BE OF HOT-DIPPED GALVANIZED STEEL,STAINLESS STEEL,SILICON BRONZE W r <br /> PLATES.8de12'oc FIELD NAILING. OR COPPER EXCEPTION:1/2'DIAMETER OR GREATER STEEL BOLTS. Wr� <br /> 2-2x STUDS �A SOILS AND FOUNDATION <br /> DRILL t EPDXY WI SIMPSON SET OR EQUIV. I� ' •' <br /> 5/8'DIA x 10'EMBED FOR HDU5 HDU HOLDOUN PER PLAN. 6d SINKERS 5 3'oc 1. FOUNDATION AND WALL AREAS SHALL HAVE ALL EXISTING UNSUITABLE FILL <br /> 1-3/4'MIN FACE DISTANCE INSTALL PER NOTE. '191 TO RIM MATERIALS REMOVED AND BE EXCAVATED DON TO SUITABLE UNDISTURBED <br /> USE EXTENDER NUT <br /> 5 <br /> AS NECESSARY. � <br /> NATIVE SOILS. DRAWN: <br /> , <br /> 2. FOOTINGS SHALL BEAR ON UNDISTURBED NATIVE SOIL OR PROPERLY COMPACTED CHECKED: <br /> DRILL 4 EPDXY W/SIMPSON ET PIP .I::', .' .a STRUCTURAL FILL.ASSUMED BEARING CAPACITY 2000 MEDATE: 08/24/17 <br /> : <br /> OR EQUIv.OR TITEN ANCHOR (2)1/2'ANCHOR Do SCALE: AS SHOWN <br /> 4'MIN.EMBED. ANCHOR BOLT BOLT.INSTALL . . .. .1g JOB NO. 17-06-106 <br /> SIZE 4 SPACING PER PLAN. PER NOTE / <br /> 'A SHEET7 !) <br /> LATERAL RESTRAINT PANEL z S 1 <br /> S1 NTS 3 ' <br /> N <br /> N <br /> OF 2 SHEETS <br /> U <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.